Nedim Tutkun

Dr. Nedim Tutkun

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Nedim TutkunNedim Tutkun
Nedim Tutkun
ABAlessandro Burgio
Alessandro Burgio
Michał JasińskiMichał Jasiński
Michał Jasiński
Zbigniew LeonowiczZbigniew Leonowicz
Zbigniew Leonowicz
EJElżbieta Jasińska
Elżbieta Jasińska
With recent developments, smart grids assured for residential customers the opportunity to schedule smart home appliances’ operation times to simultaneously reduce both the electricity bill and the PAR based on demand response, as well as increasing user comfort. It is clear that the multi-objective combinatorial optimization problem involves constraints and the consumer’s preferences, and the solution to the problem is a difficult task. There have been a limited number of investigations carried out so far to solve the indicated problems using metaheuristic techniques like particle swarm optimization, mixed-integer linear programming, and the grey wolf and crow search optimization algorithms, etc. Due to the on/off control of smart home appliances, binary-coded genetic algorithms seem to be a well-fitted approach to obtain an optimal solution. It can be said that the novelty of this work is to represent the on/off state of the smart home appliance with a binary string which undergoes crossover and mutation operations during the genetic process. Because special binary numbers represent interruptible and uninterruptible smart home appliances, new types of crossover and mutation were developed to find the most convenient solutions to the problem. Although there are a few works which were carried out using the genetic algorithms, the proposed approach is rather distinct from those employed in their work. The designed genetic software runs at least ten times, and the most fitting result is taken as the optimal solution to the indicated problem; in order to ensure the optimal result, the fitness against the generation is plotted in each run, whether it is converged or not. The simulation results are significantly encouraging and meaningful to residential customers and utilities for the achievement of the goal, and they are feasible for a wide-range applications of home energy management systems.

8 January 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
Nedim TutkunNedim Tutkun
Nedim Tutkun
ABAlessandro Burgio
Alessandro Burgio
More and more distributed generations (DGs), such as wind, PV or battery bank sources, are connected to electric systems or customer loads. However, the locations of these DGs are based on the highest energy that can be potentially harvested for electric power generation. Therefore, these locations create different line impedances based on the distance from the DGs to the loads or the point of common coupling (PCC). This paper presents an adaptive virtual impedance (AVI) in the predictive control scheme in order to ensure power sharing accuracy and voltage stability at the PCC in a microgrid network. The reference voltage from mismatched feeder impedances was modified by utilizing the suggested AVI-based predictive control for creating equal power sharing between the DGs in order to avoid overburdening any individual DG with low-rated power. The AVI strategy used droop control as the input control for generating equal power sharing, while the AVI output was used as the reference voltage for the finite control set–model predictive control (FCS-MPC) for creating a minimum voltage error deviation for the cost function (CF) for the inverter’s vector switching pattern in order to improve voltage stability at the PCC. The proposed AVI-based controller was tested using two DG inverter circuits in a decentralized control mode with different values of line impedance and rated power. The performance of the suggested controller was compared via MATLAB/Simulink with that of a controller based on static virtual impedance (SVI) in terms of efficiency of power sharing and voltage stability at the PCC. From the results, it was found that (1) the voltage transient magnitude for the AVI-based controller was reduced within less than 0.02 s, and the voltage at the PCC was maintained with about 0.9% error which is the least as compared with those for the SVI-based controller and (2) equal power sharing between the DGs increased during the change in the load demand when using the AVI-based controller as compared with using the SVI-based controller. The proposed controller was capable of giving more accurate power sharing between the DGs, as well as maintaining the voltage at the PCC, which makes it suitable for the power generation of consumer loads based on DG locations for future energy communities.

30 May 2024 in Electronics
Verified
Journal Article
Open access
PDF file
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
Nedim TutkunNedim Tutkun
Nedim Tutkun
Ismail EkmekciIsmail Ekmekci
Ismail Ekmekci
ABAlessandro Burgio
Alessandro Burgio
In islanded operation, precise power sharing is an immensely critical challenge when there are different line impedance values among the different-rated inverters connected to the same electrical network. Issues in power sharing and voltage compensation at the point of common coupling, as well as the reverse circulating current between inverters, are problems in existing control strategies for parallel-connected inverters if mismatched line impedances are not addressed. Therefore, this study aims to develop an improved decentralized controller for good power sharing with voltage compensation using the predictive control scheme and circulating current minimization between the inverters’ current flow. The controller was developed based on adaptive virtual impedance (AVI) control, combined with finite control set–model predictive control (FCS-MPC). The AVI was used for the generation of reference voltage, which responded to the parameters from the virtual impedance loop control to be the input to the FCS-MPC for a faster tracking response and to have minimum tracking error for better pulse-width modulation generation in the space-vector form. As a result, the circulating current was maintained at below 5% and the inverters were able to share an equal power based on the load required. At the end, the performance of the AVI-based control scheme was compared with those of the conventional and static-virtual-impedance-based methods, which have also been tested in simulation using MATLAB/Simulink software 2021a version. The comparison results show that the AVI FCS MPC give 5% error compared to SVI at 10% and conventional PI at 20%, in which AVI is able to minimize the circulating current when mismatch impedance is applied to the DGs.

8 May 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
Nedim TutkunNedim Tutkun
Nedim Tutkun
MŞMehmet Şimşir
Mehmet Şimşir
Parallel-connected inverters play a crucial role in the grid interface of distributed generation. The world is now moving towards sustainability, while shifting from traditional power systems to renewable energies. With the emergence of microgrids as an alternative for an uninterruptable power supply, there are significant challenges in terms of control strategies. Ensuring stability and reliability in electrical systems amidst the integration of diverse energy sources with varying power ratings into a distribution network presents the need for advanced control techniques. These techniques must effectively maintain power system quality, stability, and reliability when operating in microgrids with parallel-connected inverters. Achieving accurate power sharing under different operating conditions, compensating for voltage and frequency deviations, and maintaining a well-controlled microgrid system are essential objectives. This paper focuses on the categorization of droop-based control with multi-loop insertion approaches. Additionally, it provides a comprehensive analysis of inverter-based microgrid control techniques, emphasizing power-sharing accuracy in various conditions, and presents a detailed comparison of different control strategies.

29 May 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Nedim TutkunNedim Tutkun
Nedim Tutkun
Luigi ScarcelloLuigi Scarcello
Luigi Scarcello
Carlo MastroianniCarlo Mastroianni
Carlo Mastroianni
With smart appliances, it has been possible to achieve low-cost electricity bills in smart-grid-tied homes including photovoltaic panels and an energy-storage system. Apparently, many factors are important in achieving this and the minimization problem formulated requires a solution depending on a certain number of constraints. It should also be emphasized that electricity tariffs and the appliance operation type and range play a major role in this cost reduction, in particular, with dynamic electricity pricing usually available in a smart-grid environment. A limited number of metaheuristic methods are used to solve such a minimization problem, in which the start time of a controllable smart home appliance is the variable. However, the datasets used in many studies are different from each other and it is mostly unclear which of the proposed methods is better in this regard. In this study, we aim to minimize the daily energy consumption cost in a typical smart home with an energy-storage system integrated into a photovoltaic system under dynamic electricity pricing. While minimizing the daily energy consumption cost only, the user’s discomfort and the peak-to-average ratio inevitably tend to increase, as expected. Therefore, a balance can be established among the objectives using multi-objective optimization. Solving this problem helps comparatively reduce the daily energy consumption cost, the peak-to-average ratio and the user’s discomfort. The results are meaningful and encouraging for the optimization problem under consideration.

26 June 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
SLShasha Li
Shasha Li
CTChee Wei Tan
Chee Wei Tan
Nedim TutkunNedim Tutkun
Nedim Tutkun
This study investigates the optimal sizing of a grid-connected hybrid renewable energy microgrid. The optimization, employing a multi-objective artificial hummingbird algorithm (MOAHA) combined with fuzzy decision-making (FDM), aims to minimize the cost of energy while maximizing renewable energy utilization. MOAHA is used to generate a well-distributed Pareto front, while FDM identifies the preferred configuration under the specified decision preference. However, the preferred solution obtained is a static configuration. Most existing studies focus on such static planning, with limited attention to dynamic mapping and validation of the optimized configuration. To bridge this gap, a digital twin architecture is further proposed for hybrid renewable energy microgrids, and a corresponding digital twin system is also developed to achieve virtual representation, dynamic state mapping, operational visualization, and configuration validation. An industrial park microgrid in Urumqi is selected as the case study. The results indicate that the preferred configuration achieves a cost of energy of 0.065 $/kWh and a renewable energy utilization of 0.675. Comparative results demonstrate that the proposed framework outperforms benchmark methods in terms of convergence, solution diversity, and computational efficiency. Meanwhile, the developed digital twin system effectively supports time-series state visualization and feasibility checking of the optimized configuration.