Today, increasing numbers of batteries are installed in residential and commercial buildings; by coordinating their operation, it is possible to favor both the exploitation of renewable sources and the safe operation of electricity grids. However, how can this multitude of battery storage systems be coordinated? Using the Application Programming Interfaces of the storage systems’ manufacturers is a feasible solution, but it has a huge limitation: communication to and from storage systems must necessarily pass through the manufacturers’ cloud infrastructure. Therefore, this article presents an IoT-based solution which allows monitoring/controlling battery storage systems, independently from the manufacturers’ cloud infrastructure. More specifically, a home gateway locally controls the battery storage using local APIs via Wi-Fi on the condition that the manufacturer enables them. If not, an auxiliary device allows the home gateway to establish a wired communication with the battery storage via the SunSpec protocol. Validations tests demonstrate the effectiveness of the proposed IoT solution in monitoring and controlling ABB, Sonnen and SolarEdge storage systems.
The massive expansion of Distributed Energy Resources and schedulable loads have forced a variation of generation, transmission, and final usage of electricity towards the paradigm of Smart Communities microgrids and of Renewable Energy Communities. In the paper, the use of multiple DC microgrids for residential applications, i.e., the nanogrids, in order to compose and create a renewable energy community, is hypothesized. The DC Bus Signaling distributed control strategy for the power management of each individual nanogrid is applied to satisfy the power flow requests sent from an aggregator. It is important to underline that this is an adaptive control strategy, i.e., it is used when the nanogrid provides a service to the aggregator and when not. In addition, the value of the DC bus voltage of each nanogrid is communicated to the aggregator. In this way, the aggregator is aware of the regulation capacity that each nanogrid can provide and which flexible resources are used to provide this capacity. The effectiveness of the proposed control strategy is demonstrated via numerical experiments. The energy community considered in the paper consists of five nanogrids, interfaced to a common ML-LV substation. The nanogrids, equipped with a photovoltaic plant and a set of lithium-ion batteries, participate in the balancing service depending on its local generation and storage capacity.
In islanded operation, precise power sharing is an immensely critical challenge when there are different line impedance values among the different-rated inverters connected to the same electrical network. Issues in power sharing and voltage compensation at the point of common coupling, as well as the reverse circulating current between inverters, are problems in existing control strategies for parallel-connected inverters if mismatched line impedances are not addressed. Therefore, this study aims to develop an improved decentralized controller for good power sharing with voltage compensation using the predictive control scheme and circulating current minimization between the inverters’ current flow. The controller was developed based on adaptive virtual impedance (AVI) control, combined with finite control set–model predictive control (FCS-MPC). The AVI was used for the generation of reference voltage, which responded to the parameters from the virtual impedance loop control to be the input to the FCS-MPC for a faster tracking response and to have minimum tracking error for better pulse-width modulation generation in the space-vector form. As a result, the circulating current was maintained at below 5% and the inverters were able to share an equal power based on the load required. At the end, the performance of the AVI-based control scheme was compared with those of the conventional and static-virtual-impedance-based methods, which have also been tested in simulation using MATLAB/Simulink software 2021a version. The comparison results show that the AVI FCS MPC give 5% error compared to SVI at 10% and conventional PI at 20%, in which AVI is able to minimize the circulating current when mismatch impedance is applied to the DGs.