Xuesen Li

Dr. Xuesen Li


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2022 in Crystals
Verified
Journal Article
Open access
PDF file
JDJie Dai
Jie Dai
XLXuesen Li
Xuesen Li
YZYadi Zhao
Yadi Zhao
QXQikeng Xu
Qikeng Xu
To improve the thermal insulation properties and toughness of concrete, the glazed hollow bead (GHB) and polyvinyl alcohol (PVA) fiber reinforced cementitious composites (GPCC) were investigated by orthogonal test, which includes six GHB mass percentage (20%, 40%, 60%, 80%,100%, 120%), three PVA volume fraction (1%, 1.5%, 2%) and water binder ratio (0.26, 0.30, 0.34). Compressive, split tensile strengths and thermal conductivity of GHB-PVA reinforced cementitious composites (GPCC) were tested, and the mechanism of fibers was analyzed from a microscopic perspective. The results revealed that the thermal insulation will be significantly improved with the increased content of GHB, but the compressive and split tensile strength will be decreased simultaneously. No obvious effect was found by the PVA fiber addition on its strength indexes, and the presence of GHB will affect the bridging action of PVA fibers. The water binder ratio has more effect on strengths than thermal conductivity. Based on the mechanical performance rather than the thermal insulation analysis test, the optimal mix proportions were proposed: mass percentage of 40% GHB, a volume fraction of 1.5% PVA fiber, and 0.26 water-binder ratio. Moreover, the anchoring and bridging effect of PVA fibers will effectively balance the stress generated by the shrinkage of cement paste, and inhibits or even prevents the development of cracks. However, a certain number of tiny cracks will be formed near the GHB, and between GHB and PVA fibers, which will cause local stretching and peeling of PVA, and shattering inside the GHB with the increase of external force. The findings of this study can provide a useful reference for the application of an insulated-bearing material with GHB and PVA fiber.

1 January 2022 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
XLXuesen Li
Xuesen Li
YDYonggang Ding
Yonggang Ding
XLXuesen Li
Xuesen Li
QXQikeng Xu
Qikeng Xu
The walls of grain cottage silos are still being built by clay brick masonry featured with single‐structure form, poor air tightness, large workload of manual masonry on site, and huge consumption of raw materials and burning materials, which is not conducive to energy saving and environmental protection. In order to study the mechanical function of the new wall under the action of grain side pressure, the static loading test was conducted on the model of scaled‐down wall panel under the action of side pressure. The damage process, the damage pattern, and the bearing capacity of the wall panel were studied through the analysis of the crack development process and distribution law to reveal the force characteristics of the wall panel. The test results show that the span deflection of the “structure‐insulation” integrated wall panel under the lateral pressure meets the requirement of the limit state of normal use; the inner and outer leaf wall panels can work together under the action of the joint; the ratio of the load borne by the inner and outer leaf wall panels is equal to the ratio of their stiffness; the flexural stiffness of the wall panels after cracking is proposed based on the combined effect analysis. Based on the analysis of the combined effect, the degradation factor of the wall panel after cracking is proposed, and the deflection calculation formula of the inner and outer leaf wall panel is established, which provides a theoretical basis for the design and the promotion of the “structure‐insulation” integrated wall panel.

7 May 2024 in Buildings
Verified
Journal Article
Open access
PDF file
ZXZhen-Hua Xu
Zhen-Hua Xu
XLXuesen Li
Xuesen Li
GBGuoliang Bai
Guoliang Bai
YDYonggang Ding
Yonggang Ding
Irregularity in the plane layout of a building structure and the vertical discontinuity of lateral resistance components could lead to torsion and result in the brittle failure of a structure. According to the characteristics of the conventional island main building of nuclear power plants, this paper focuses on the conventional island main building of the CAP1400 nuclear power plant (NPP) in Shidaowan as the research object. A prototype structure model of the main building was developed using ABAQUS software. The seismic response of the structure under multidimensional ground motion was studied by inputting the X-direction and Y-direction translational and torsional components of ground motion in ABAQUS. The results demonstrate that the overall transverse displacement of the structure under bidirectional ground motion was significantly higher than that under unidirectional earthquakes, which was about 20%. Under a multidimensional frequent earthquake, the transverse displacement of the structure increased by about 13% on average compared with that under a bidirectional earthquake; the longitudinal increase was the largest, at about 28%. Finally, the lateral displacement of each layer of the steel-reinforced concrete (SRC) frame-bent main building structure with few walls proposed in this article decreased by an average of about 17% compared to the traditional SRC frame-bent main building structure. The longitudinal displacement was reduced by about 14% compared to the traditional SRC frame-bent main building structure.

29 March 2026 in Buildings
Verified
Journal Article
Open access
PDF file
LYLinna Yin
Linna Yin
HSHaili Shi
Haili Shi
QNQiujun Ning
Qiujun Ning
JLJiawei Lu
Jiawei Lu
XLXuesen Li
Xuesen Li
In this study, experimental, numerical, and theoretical approaches were conducted to investigate the stability bearing capacity of the 6061-T6 aluminum alloy thin-walled tubular members under axial compression. Initially, a total of 12 6061-T6 aluminum alloy thin-walled tubular members were tested under axial compression, together with initial geometric imperfection measurements. Subsequently, the experimentally validated finite element (FE) model was established using ABAQUS, and a large number of parametric analyses were carried out via this model to investigate the effects of the initial imperfection, the cross-section size and the strain-hardening exponent on the overall stability of the component. Finally, a calculating formula for the strength and overall stability of aluminum alloy axial compression members is proposed based on the continuous strength method (CSM). The analysis results showed that the initial geometric imperfection and strain-hardening exponent have a significant effect on the axial compression stability coefficient of the small slenderness ratio aluminum alloy members. When the relative slenderness ratio is greater than 0.75 and less than 2, the strain-hardening exponent has a great influence on the aluminum alloy axial compression stability coefficient. The proposed strength and overall stability calculation formula of aluminum alloy axial compression members, which is based on CSM, can accurately predict the stability bearing capacity of the aluminum alloy.

15 July 2025 in Structural Concrete
Verified
Journal Article
Closed access
XLXuesen Li
Xuesen Li
CYChao‐Hui Yang
Chao‐Hui Yang
ZXZhen-Hua Xu
Zhen-Hua Xu
CGCheng‐Zhou Guo
Cheng‐Zhou Guo
LZLong Zhou
Long Zhou

26 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZLZidan Li
Zidan Li
YDYonggang Ding
Yonggang Ding
XLXuesen Li
Xuesen Li
CGChengzhou Guo
Chengzhou Guo
ZXZhenhua Xu
Zhenhua Xu
RYRongyu Yang
Rongyu Yang
Multi-floored grain warehouses are widely used in China due to their efficient space utilization and high storage capacity. This study evaluates the seismic performance of such structures using a Composite Structure of Steel and Concrete (CSSC) system under various grain-loading conditions. A finite element model was developed in OpenSees based on actual loading scenarios, with both pushover and time history analyses conducted. Results show that the EEF condition (E = Empty, F = Full; top–middle–bottom = Empty–Empty–Full) leads to a 35.14% increase in peak base shear compared to the FEE condition (grain on the top floor only). Capacity spectrum analysis indicates that EEF provides higher initial stiffness and lower displacement across all performance points. Time history results reveal that configurations with lighter upper mass (EFF, EEE) are more prone to top-floor acceleration amplification, while FFF and FFE demonstrate more stable responses due to balanced mass distribution. The maximum inter-story drift consistently occurs at the second floor, with FFF and FFE showing the most significant deformation. All drift ratios meet code limits, confirming the safety and applicability of the CSSC system under various storage scenarios.