Qikeng Xu

Dr. Qikeng Xu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2024 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
YDYonggang Ding
Yonggang Ding
HSHuan Suo
Huan Suo
QXQikeng Xu
Qikeng Xu
JCJia Chen
Jia Chen
QLQiang Liu
Qiang Liu
Under earthquake action, the storage material has the shock absorption and energy consumption effect on the silo due to the friction of the particles-particles and the interaction of grains–silo wall. In order to quantify the magnitude of this energy dissipating effect, a method for calculating the effective mass coefficient of column-supported silos under earthquake action has been proposed. In this paper, based on the experimental analysis, the effective mass calculation formula is derived by using the quasi-static equilibrium equation for the storage unit (micrometric layer). In addition, shaking table tests were conducted to verify the validity of the method. The results show that the proposed method can be used to assess the effective mass of stored materials under earthquakes. The effective mass coefficient increases with the peak acceleration and shows an almost non-linear increasing trend with the silo height. The results obtained from the proposed method and experiments in this paper are significantly less than the 0.8 specified by Eurocode 8. Finally, the values range of effective mass coefficient from in the case of three particle filling heights are determined to facilitate engineering applications, including 0.64 – 0.77 for full particles, 0.51 – 0.78 for three-quarter particles, and 0.56 – 0.77 for half particles.

15 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WGWang Guiling
Wang Guiling
QXQikeng Xu
Qikeng Xu
YDYonggang Ding
Yonggang Ding
JLJianye Li
Jianye Li
QLQiang Liu
Qiang Liu
Under earthquake action, concrete silos can undergo damage over a vast area or may even collapse. To aid seismic design, a numerical simulation of the seismic performance of column-supported reinforced concrete silos was performed, and the performance was quantitatively described. The focus of the research was on determining the damage levels of these silos by adopting an incremental dynamic analysis. The focus of the research was on determining the damage levels of these silos by adopting an incremental dynamic analysis. Four limit states were defined for the first time so as to better determine the damage states of column-supported reinforced concrete silos in the event of earthquakes and the vulnerability analysis of the silo structures was carried out. The analysis results show that volume of the stored grain directly determined its damage behavior. The silo with a greater amount of stored grain entered the plastic state earlier, and the damage effect was more evident. Under the most dangerous working conditions, i.e., the full state of the silo, the 50-year collapse exceedance probability of the silo reaching collapse (LS4) was less than 1% of the 50-year failure risk limit defined in the US seismic design code FEMA P750. This demonstrated that a column-supported reinforced concrete silo can maintain its high anti-collapse reserve capacity under the effect of rare earthquakes.

24 March 2022 in Crystals
Verified
Journal Article
Open access
PDF file
JDJie Dai
Jie Dai
XLXuesen Li
Xuesen Li
YZYadi Zhao
Yadi Zhao
QXQikeng Xu
Qikeng Xu
To improve the thermal insulation properties and toughness of concrete, the glazed hollow bead (GHB) and polyvinyl alcohol (PVA) fiber reinforced cementitious composites (GPCC) were investigated by orthogonal test, which includes six GHB mass percentage (20%, 40%, 60%, 80%,100%, 120%), three PVA volume fraction (1%, 1.5%, 2%) and water binder ratio (0.26, 0.30, 0.34). Compressive, split tensile strengths and thermal conductivity of GHB-PVA reinforced cementitious composites (GPCC) were tested, and the mechanism of fibers was analyzed from a microscopic perspective. The results revealed that the thermal insulation will be significantly improved with the increased content of GHB, but the compressive and split tensile strength will be decreased simultaneously. No obvious effect was found by the PVA fiber addition on its strength indexes, and the presence of GHB will affect the bridging action of PVA fibers. The water binder ratio has more effect on strengths than thermal conductivity. Based on the mechanical performance rather than the thermal insulation analysis test, the optimal mix proportions were proposed: mass percentage of 40% GHB, a volume fraction of 1.5% PVA fiber, and 0.26 water-binder ratio. Moreover, the anchoring and bridging effect of PVA fibers will effectively balance the stress generated by the shrinkage of cement paste, and inhibits or even prevents the development of cracks. However, a certain number of tiny cracks will be formed near the GHB, and between GHB and PVA fibers, which will cause local stretching and peeling of PVA, and shattering inside the GHB with the increase of external force. The findings of this study can provide a useful reference for the application of an insulated-bearing material with GHB and PVA fiber.

8 August 2025 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
ZYZhang Yanan
Zhang Yanan
QXQikeng Xu
Qikeng Xu
HYHuang Yilin
Huang Yilin
DYDing Yonggang
Ding Yonggang
WGWang Guiling
Wang Guiling

28 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
WHWang Huifen
Wang Huifen
YDYonggang Ding
Yonggang Ding
XLXuesen Li
Xuesen Li
GRGuo Qi Ren
Guo Qi Ren
ZZZhiyao Zhou
Zhiyao Zhou
QXQikeng Xu
Qikeng Xu
Food security is a critical component of national security. Grain silos, as key infrastructure for food storage, must remain structurally resilient under seismic actions to ensure the stability of grain reserves. However, column-supported vertical-group silo structures are prone to spatial torsional effects during earthquakes due to eccentricities between the mass center and the stiffness center after grain loading, which can lead to serious structural damage or collapse. Based on this background, shaking table tests were conducted on a column-supported vertical-group silo structure as the research subject, with a scale ratio of 1/25 and in the 1 row × 3 column combination form. The dynamic response and spatial torsional effect of the structure under different grain storage conditions and seismic intensity effects were studied. To thoroughly analyze the factors influencing the spatial torsion in the structure, finite element–discrete element numerical analysis models of the structure were established based on experiments in Abaqus (6.14) software. The results indicate that in the column-supported vertical-group silo structure, the mass center of the group silo structure deviates from its center of rigidity after grain storage, resulting in significant and irregular spatial torsional effects under earthquake motion. The torsional displacement ratio and inter-story horizontal torsional angle of the structure gradually increased with an increase in the seismic intensity, reaching maximum values of 1.34 and 0.035 rad, respectively, when the peak acceleration input on the table was 0.4 g and under the full–full–empty storage condition. The effects of the void distribution, mass void ratio, and combination form of the group silo structure on the spatial torsional effect of the structure were studied to provide a scientific reference for the seismic design of column-supported silo structures for grain storage.

19 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WHWang Huifen
Wang Huifen
YDYonggang Ding
Yonggang Ding
WGWang Guiling
Wang Guiling
QXQikeng Xu
Qikeng Xu
YZYanan Zhang
Yanan Zhang
The storage conditions of multi-floor grain warehouses change frequently during grain circulation. This paper investigates the effects of various storage conditions on the seismic performance of multi-floor grain warehouses. The numerical results indicate that the higher the storage material distribution position, the greater the damping ratio of the structural model and the more obvious the contribution of storage material movement to the damping of the structure. The intensity of earthquake action and the spatial height of the floor where the storage material is located are negatively correlated with the acceleration response of the structure. Under full-silo conditions, when the peak ground acceleration (PGA) is 0.4 g, the acceleration amplification factor at the top of the structure is 69.7% of the corresponding parameter at 0.1 g. The discontinuity in the storage space of the structure results in a torsional effect on the structure. When PGA = 0.22 g, the peak inter-story displacement angle of the first floor differs by nearly 1.7 times under different operating conditions, and the peak inter-story displacement angle of the second floor during an earthquake with PGA = 0.40 g differs by about 1.5 times under different operating conditions. The lateral pressure of the silo wall at different burial depths under earthquake action shows a highly nonlinear distribution trend, and the overpressure coefficient at the same burial depth of the warehouse wall is proportional to the PGA of the earthquake action. During 0.1 g, 0.22 g, and 0.40 g earthquakes, the maximum overpressure coefficients at the bottom of the warehouse wall on different floors are 1.13, 1.21, and 1.66, respectively.