28 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
CBCésar Augusto Santana Castelo Branco
César Augusto Santana Castelo Branco
FMFabricio Pereira Moraes
Fabricio Pereira Moraes
HOHercules Araujo Oliveira
Hercules Araujo Oliveira
Pedro BezerraPedro Bezerra
Pedro Bezerra
Osvaldo Ronald SaavedraOsvaldo Ronald Saavedra
Osvaldo Ronald Saavedra
RCRogério Moreira Cazo
Rogério Moreira Cazo
This article reports the conception and design of a mission critical microgrid to serve a critical infrastructure application, namely, the Alcântara Space Launch Center, a government military facility in Brazil. The assumptions, general characteristics, requirements and particularities arising from the application are established and discussed in detail. High resilience and energy security are required in critical periods of operation, demanding a power supply infrastructure composed of redundant and dispachable sources capable of supporting n−1 generation contingencies. Whereas, in the remaining time, economic and environmental aspects take place as main requests. Operation scenarios, on both grid-connected (on-grid) and isolated (off-grid) modes, are formulated as optimization problems and simulations have been performed to analyze these scenarios, which are reported and analyzed here. The off-grid operation, which is clearly more complex, is preferentially addressed, especially in scenarios with contingencies. In this context, the proposed microgrid is conceived to satisfactorily balance requirements such as the economy, pollutant emission reduction, high reliability, resilience and operational security, which are requested by this critical infrastructure application.

21 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
HOHercules Araujo Oliveira
Hercules Araujo Oliveira
JMJose Gomes de Matos
Jose Gomes de Matos
LRLuiz Antonio De Souza Ribeiro
Luiz Antonio De Souza Ribeiro
Osvaldo Ronald SaavedraOsvaldo Ronald Saavedra
Osvaldo Ronald Saavedra
Jerson VazJerson Vaz
Jerson Vaz
Blade Element Momentum Theory (BEMT) is the most used method to design horizontal-axis wind turbines worldwide. This is because BEMT has a low computational cost and easy numerical implementation. Additionally, it is demonstrated in the literature that the prediction of output power using BEMT agrees well with experimental data. Another important feature of the BEMT is its applicability to small, medium, and large-sized turbines. However, BEMT models are usually implemented and adjusted for a specific power range turbine, and they are not applied in a more general form. Thus, this article presents an analysis of additional correction methods for tip and root losses, high values of the axial induction factor, and high angle of attack to better represent horizontal-axis turbines in terms of numerical stability. The approach has the intention of combining several complementary correction methods strategically inserted in the BEMT in order to compile an algorithm that is more general, stable, and workable for any turbine size. The main contribution of this work is to propose a stable BEMT numerical algorithm through the assessment of the combination of the correction methods available in the literature, i.e., classical and modern ones. The algorithm ensures applicability for small, medium, and large-sized wind turbines, as well as being fast and easy to implement in any computer and extendable even to turbines with a diffuser. This approach is validated by comparing the results with experimental data from four turbines of different power ranges (1.9 kW to 7.3 MW). The results show the best approximations for performance power curves against the measured values of all turbines. Moreover, it is effective, less complex, and quick in analyzing the performance of those turbines. Furthermore, the need for high-performance computers to analyze the performance of horizontal-axis turbines is avoided.

29 April 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
HOHercules Araujo Oliveira
Hercules Araujo Oliveira
JMJose Gomes de Matos
Jose Gomes de Matos
LRLuiz Antonio De Souza Ribeiro
Luiz Antonio De Souza Ribeiro
Osvaldo Ronald SaavedraOsvaldo Ronald Saavedra
Osvaldo Ronald Saavedra
ALAlexandre de Andrade Lorencato
Alexandre de Andrade Lorencato
LPLucas de Paula Assuncao Pinheiro
Lucas de Paula Assuncao Pinheiro
Isolated microgrids need dispatchable energy sources to ensure continuity of service during lack of the renewable energy sources. One common source is the diesel generator which is used as a backup and for battery charges. Practical experiences have shown that microgrids have operation problems when diesel generators and rectifiers work together to charge battery banks. This is because of resulting diesel generator voltage distortions caused by the interaction of line currents harmonics with equivalent series reactance of the AC source and the notches introduced during the current commutation between 2 SCRs of the bridge rectifier. These distortions eventually inhibit the rectifier operation, causing malfunctioning of the system. One solution is to use generators with rated power greater than the rectifiers, which results in oversized installation and high operating costs. This work proposes a solution to avoid generator oversizing by using resonant filters, notch filter and a capacitive reactive compensation circuit to avoid self-excitation of the generator. Soft-start operation of the rectifier, and disturbance decoupling in the generator are also proposed. The design allows the use of generators and rectifiers of similar power, reducing the installation and operation costs of microgrids. It has been used successfully in two real-life microgrids.

23 January 2025 in Eletrônica de Potência
Verified
Journal Article
Open access
PDF file
HOHercules Araujo Oliveira
Hercules Araujo Oliveira
LSLuiza H. S. Santos
Luiza H. S. Santos
LRLuiz Antonio De Souza Ribeiro
Luiz Antonio De Souza Ribeiro
JMJose Gomes de Matos
Jose Gomes de Matos
LPLucas de P. A. Pinheiro
Lucas de P. A. Pinheiro
This paper presents and discusses challenges in microgrids (uGrid) that arise when they operate isolated from the main grid. Specifically, these challenges occur because the system becomes an ungrounded delta configuration, and the microgrid power sources exhibit low short-circuit capacity. The important issues addressed include the failure to detect ground overcurrent during an earth fault event, voltage imbalances recorded by voltage transformers (VTs) connected between phases and earth, and the phenomenon of ferroresonance. These issues directly impact the coordination of electrical protection, component integrity, and synchronization checks between different power sources within the uGrid. Therefore, the Energy Management System (EMS) is tasked with managing protection devices and systematically responding to minimize disruptions, thereby ensuring operational security. This paper examines the protection functions within devices for both operational modes (on-grid and off-grid) and the corresponding decisions implemented as rules within the EMS. Effective coordination between protection devices and management systems ensures a rapid and selective response to faults, thereby enhancing microgrid security and facilitating efficient problem detection and resolution.