This work presents a droop-based control strategy for a dc nanogrid designed to operate under the Net Zero Energy (NZE) concept, enabling seamless transitions between grid-connected and islanded modes. The nanogrid integrates photovoltaic (PV) generation, a fast electric vehicle charging station (EVSE), and a battery energy storage system (BESS) into a $700~$V dc bus interfacing with the ac grid via a bidirectional three-phase AC-DC converter. An isolated DC-DC converter establishes a secondary $48~$V dc bus for powering dc loads. An energy management system (EMS) defines an optimal day-ahead power dispatch for the BESS to meet NZE objectives. At the primary control level, a modified power-to-voltage droop strategy ensures accurate power tracking and parallel operation with the AC-DC converter. This approach enables continuous voltage regulation of the main bus under instantaneous power imbalances caused by schedule deviations or operational mode transitions. Additionally, the proposed strategy eliminates the need for secondary control or high-bandwidth communication. The system is validated through hardware-in-the-loop (HIL) simulations using the Typhoon HIL 604 platform, with the control strategy implemented on a DSP. Real-time simulation results confirm stable performance under various operating conditions, including transitions between modes.
This paper presents and discusses challenges in microgrids (uGrid) that arise when they operate isolated from the main grid. Specifically, these challenges occur because the system becomes an ungrounded delta configuration, and the microgrid power sources exhibit low short-circuit capacity. The important issues addressed include the failure to detect ground overcurrent during an earth fault event, voltage imbalances recorded by voltage transformers (VTs) connected between phases and earth, and the phenomenon of ferroresonance. These issues directly impact the coordination of electrical protection, component integrity, and synchronization checks between different power sources within the uGrid. Therefore, the Energy Management System (EMS) is tasked with managing protection devices and systematically responding to minimize disruptions, thereby ensuring operational security. This paper examines the protection functions within devices for both operational modes (on-grid and off-grid) and the corresponding decisions implemented as rules within the EMS. Effective coordination between protection devices and management systems ensures a rapid and selective response to faults, thereby enhancing microgrid security and facilitating efficient problem detection and resolution.
11 August 2022 in Journal of Control, Automation and Electrical Systems
This paper presents GridFlexPy, an open-source Python framework that enables user-friendly power flow analysis and Battery Energy Storage System (BESS) operation in microgrids, leveraging direct integration with OpenDSS through the OpenDSSDirect library. The framework supports both standalone simulations and seamless integration with optimization workflows. GridFlexPy facilitates the strategic allocation and operation of BESSs to address challenges such as demand curve smoothing and loss reduction associated with the intermittency of renewable generation. The framework is validated on a 14-bus microgrid test case, in which different BESS allocations are analyzed for their impact on key performance indicators related to demand smoothing and energy losses. Results show that the optimal allocation led to a 53 % reduction in the demand fluctuation index and a 14 % reduction in total annual energy losses. These results demonstrate that GridFlexPy efficiently supports BESS studies and provides a flexible platform for researchers and practitioners in power system analysis and planning.