Spectral imaging has many applications, from methane detection using satellites to disease detection on crops. However, spectral cameras remain a costly solution ranging from 10 thousand to 100 thousand euros for the hardware alone. Here, we present a low-cost multispectral camera (LC-MSC) with 64 LEDs in eight different colors and a monochrome camera with a hardware cost of 340 euros. Our prototype reproduces spectra accurately when compared to a reference spectrometer to within the spectral width of the LEDs used and the ±1 variation over the surface of ceramic reference tiles. The mean absolute difference in reflectance is an overestimate of 0.03 for the LC-MSC as compared to a spectrometer, due to the spectral shape of the tiles. In environmental light levels of 0.5 W m−2 (bright artificial indoor lighting) our approach shows an increase in noise, but still faithfully reproduces discrete reflectance spectra over 400 nm–1000 nm. Our approach is limited in its application by LED bandwidth and availability of specific LED wavelengths. However, unlike with conventional spectral cameras, the pixel pitch of the camera itself is not limited, providing higher image resolution than typical high-end multi- and hyperspectral cameras. For sample conditions where LED illumination bands provide suitable spectral information, our LC-MSC is an interesting low-cost alternative approach to spectral imaging.
We report on the calibration and testing of a fiber Bragg grating (FBG)-based 2D-shape sensing strip for real-time monitoring of the position and orientation of the human spine during gait. The strip is evaluated for its use as an input for control of an exoskeleton for patients with spinal cord injury. By measuring the torsion and bending of the back, walking movements can be reconstructed. The 3D-printed strip has nine embedded fiber Bragg gratings that are located at specific places with respect to the vertebral column. Three FBGs are placed opposite to the thoracic vertebrae T6–T9, these FBGs are sensitive for measuring the bending of the spine during the gait cycle. Torsion is measured at two locations: at thoracic vertebra, T3 and at lumbar vertebra, L3. At these locations, the width of the strip is reduced to have a larger sensitivity for torsion. The strain at each FBG is measured using an interrogator. This leads to the radius of curvature and torsion as a function of time. The Frenet-Serret formulae are used to calculate the shape of the strip during the gait cycle. We have calibrated this FBG strip for curvature by bending it at known radius of different curvatures. We found a linear dependence between the strain and curvature. For torsion calibration we have rotated the strip with a stepper motor at different angles and monitored the strain. We, again, found a linear dependence with a small hysteresis. We mounted the strip on a healthy test subject and monitored their gait cycle. The FBG strip shows similar results when compared to a motion capture system based on multiple cameras. Although the fixation of the strip to a garment or on the back directly strongly influences the measured response, it does show a periodic and reproducible signal during the gait cycle.