Plastic waste and pollution is growing rapidly worldwide and most plastics end up in landfill or are incinerated because high-quality recycling is not possible. Plastic-type identification with a low-cost, handheld spectral approach could help in parts of the world where high-end spectral imaging systems on conveyor belts cannot be implemented. Here, we investigate how two fundamentally different handheld infrared spectral devices can identify plastic types by benchmarking the same analysis against a high-resolution bench-top spectral approach. We used the handheld Plastic Scanner, which measures a discrete infrared spectrum using LED illumination at different wavelengths, and the SpectraPod, which has an integrated photonics chip which has varying responsivity in different channels in the near-infrared. We employ machine learning using SVM, XGBoost, Random Forest and Gaussian Naïve Bayes models on a full dataset of plastic samples of PET, HDPE, PVC, LDPE, PP and PS, with samples of varying shape, color and opacity, as measured with three different experimental approaches. The high-resolution spectral approach can obtain an accuracy (mean ± standard deviation) of (0.97 ± 0.01), whereas we obtain (0.93 ± 0.01) for the SpectraPod and (0.70 ± 0.03) for the Plastic Scanner. Differences of reflectance at subsequent wavelengths prove to be the most important features in the plastic-type classification model when using high-resolution spectroscopy, which is not possible with the other two devices. Lower accuracy for the handheld devices is caused by their limitations, as the spectral range of both devices is limited—up to 1600 nm for the SpectraPod, while the Plastic Scanner has limited sensitivity to reflectance at wavelengths of 1100 and 1350 nm, where certain plastic types show characteristic absorbance bands. We suggest that combining selective sensitivity channels (as in the SpectraPod) and illuminating the sample with varying LEDs (as with the Plastic Scanner) could increase the accuracy in plastic-type identification with a handheld device.
We have developed an SI-traceable narrow-band tunable radiance source based on an optical parametric oscillator (OPO) and an integrating sphere for the calibration of spectroradiometers. The source is calibrated with a reference detector over the ultraviolet/visible spectral range with an uncertainty of . As a case study, a CubeSat spectroradiometer has been calibrated for radiance over its operating range from 370 nm to 480 nm. To validate the results, the instrument has also been calibrated with a traditional setup based on a diffuser and an FEL lamp. Both routes show good agreement within the combined measurement uncertainty. The OPO-based approach could be an interesting alternative to the traditional method, not only because of reduced measurement uncertainty, but also because it directly allows for wavelength calibration and characterization of the instrumental spectral response function and stray light effects, which could reduce calibration time and cost.
Spectral imaging has many applications, from methane detection using satellites to disease detection on crops. However, spectral cameras remain a costly solution ranging from 10 thousand to 100 thousand euros for the hardware alone. Here, we present a low-cost multispectral camera (LC-MSC) with 64 LEDs in eight different colors and a monochrome camera with a hardware cost of 340 euros. Our prototype reproduces spectra accurately when compared to a reference spectrometer to within the spectral width of the LEDs used and the ±1 variation over the surface of ceramic reference tiles. The mean absolute difference in reflectance is an overestimate of 0.03 for the LC-MSC as compared to a spectrometer, due to the spectral shape of the tiles. In environmental light levels of 0.5 W m−2 (bright artificial indoor lighting) our approach shows an increase in noise, but still faithfully reproduces discrete reflectance spectra over 400 nm–1000 nm. Our approach is limited in its application by LED bandwidth and availability of specific LED wavelengths. However, unlike with conventional spectral cameras, the pixel pitch of the camera itself is not limited, providing higher image resolution than typical high-end multi- and hyperspectral cameras. For sample conditions where LED illumination bands provide suitable spectral information, our LC-MSC is an interesting low-cost alternative approach to spectral imaging.
A spectral imager is calibrated for radiance with an uncertainty < 1 % using an SI-traceable narrow-band tunable radiance source, which is based on an optical parametric oscillator and an integrating sphere.
We report on the calibration and testing of a fiber Bragg grating (FBG)-based 2D-shape sensing strip for real-time monitoring of the position and orientation of the human spine during gait. The strip is evaluated for its use as an input for control of an exoskeleton for patients with spinal cord injury. By measuring the torsion and bending of the back, walking movements can be reconstructed. The 3D-printed strip has nine embedded fiber Bragg gratings that are located at specific places with respect to the vertebral column. Three FBGs are placed opposite to the thoracic vertebrae T6–T9, these FBGs are sensitive for measuring the bending of the spine during the gait cycle. Torsion is measured at two locations: at thoracic vertebra, T3 and at lumbar vertebra, L3. At these locations, the width of the strip is reduced to have a larger sensitivity for torsion. The strain at each FBG is measured using an interrogator. This leads to the radius of curvature and torsion as a function of time. The Frenet-Serret formulae are used to calculate the shape of the strip during the gait cycle. We have calibrated this FBG strip for curvature by bending it at known radius of different curvatures. We found a linear dependence between the strain and curvature. For torsion calibration we have rotated the strip with a stepper motor at different angles and monitored the strain. We, again, found a linear dependence with a small hysteresis. We mounted the strip on a healthy test subject and monitored their gait cycle. The FBG strip shows similar results when compared to a motion capture system based on multiple cameras. Although the fixation of the strip to a garment or on the back directly strongly influences the measured response, it does show a periodic and reproducible signal during the gait cycle.
Precision greenhouse agriculture enhances plant health and crop yields by continuously monitoring key plant parameters. Stem diameter is such a parameter and is monitored to support decisions on plant care. However, traditional contact-based methods induce thigmomorphogenic effects that impact plant growth. Here, we introduce the Optical Caliper (OC), a novel contactless device for precise, non-invasive stem diameter measurement. The OC operates by projecting a collimated light beam to cast a shadow of the stem onto a high-resolution image sensor. The shadow size is a measure for the stem diameter. Controlled laboratory tests show the OC offers an accuracy comparable to that of a Digital Caliper (DC). Field trials on irregular tomato and cucumber stems demonstrate a repeatability of 0.1–0.2 mm. The OC’s non-invasive design and high repeatability exceed the performance of a DC, making it particularly suited for accurately monitoring soft, variable plant structures. Bringing the advantage of avoiding thigmomophogenic effects and thus optimizing crop yield, the OC is a promising tool for high-throughput plant phenotyping and precision agriculture applications.