The enormous advances in sensing and data processing technologies in combination with recent developments in nuclear radiation detection and imaging enable unprecedented and “smarter” ways to detect, map, and visualize nuclear radiation. The recently developed concept of three-dimensional (3-D) Scene-data fusion allows us now to “see” nuclear radiation in three dimensions, in real time, and specific to radionuclides. It is based on a multi-sensor instrument that is able to map a local scene and to fuse the scene data with nuclear radiation data in 3-D while the instrument is freely moving through the scene. This new concept is agnostic of the deployment platform and the specific radiation detection or imaging modality. We have demonstrated this 3-D Scene-data fusion concept in a range of configurations in locations, such as the Fukushima Prefecture in Japan or Chernobyl in Ukraine on unmanned and manned aerial and ground-based platforms. It provides new means in the detection, mapping, and visualization of radiological and nuclear materials relevant for the safe and secure operation of nuclear and radiological facilities or in the response to accidental or intentional releases of radioactive materials where a timely, accurate, and effective assessment is critical. In addition, the ability to visualize nuclear radiation in 3-D and in real time provides new means in the communication with public and facilitates to overcome one of the major public concerns of not being able to “see” nuclear radiation.
Exploiting the moderate Cherenkov yield from 511 keV photoelectric interactions in bismuth germanate (BGO) scintillators enables one to achieve a level of coincidence time resolution (CTR) appropriate for time-of-flight positron emission tomography (TOF-PET). For this approach, owing to the low number of promptly emitted light photons, single photon time resolution (SPTR) can have a stronger influence on achievable CTR. We have previously shown readout techniques that reduce effective device capacitance of large area silicon photomultipliers (SiPMs) can yield improvements in single photon response shape that minimize the influence of electronic noise on SPTR. With these techniques, sub-100 ps FWHM SPTR can be achieved with mm 2 FBK near-ultra-violet high density (NUV-HD) SiPMs. These sensors are also useful for detecting Cherenkov light due to relatively high photon detection efficiency for UV light. In this work, we measured CTR for BGO crystals coupled to FBK NUV-HD SiPMs with a passive bootstrapping readout circuit that effectively reduces the SiPM device capacitance. A range of CTR values between 200 3 and 277 7 ps FWHM were measured for 3 3 3 and 3 3 15 mm 3 crystals, respectively. This readout technique provides a relatively simple approach to achieve state-of-the-art CTR performance using BGO crystals for TOF-PET.
26 September 2022 in Physics in Medicine & Biology
State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.
27 September 2021 in IEEE Transactions on Nuclear Science
Using a series of detector measurements taken at different locations to localize a source of radiation is a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of the point source can be found using techniques such as maximum likelihood. Recent advancements have shown the ability to locate point sources in 2-D and even 3-D but few have studied the effect of intervening material on the problem. In this work, we examine gamma-ray data taken from a freely moving system and develop voxelized 3-D models of the scene using data from its onboard light detection and ranging (LiDAR) unit. Ray casting is used to compute the distance each gamma ray travels through the scene material, which is then used to calculate attenuation assuming a single attenuation coefficient for solids within the geometry. Parameter estimation using maximum likelihood is performed to simultaneously find the attenuation coefficient, source activity, and source position that best match the data. Using a simulation, we validate the ability of this method to reconstruct the true location and activity of a source, along with the true attenuation coefficient of the structure it is inside, and then we apply the method to measured data with sources and find good agreement.
2 November 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
We have evaluated the coincidence time resolution (CTR) performance of four different mixed-signal front-end electronic readout configurations with the goal to achieve 100 picoseconds (ps) CTR. The proposed TOF-PET detector elements are based on two $3{\times } 3{\times }10$ mm 3 “fast LGSO” crystal segments, side coupled to linear arrays of $3{\times }3$ mm 2 silicon photomultipliers (SiPMs), to form a total crystal length of 20 mm. We studied multiple configurations and components for the front-end readout: 1) high speed radio frequency (RF) amplifiers; 2) an ASIC-based discriminator; 3) a combination of RF amplifier, balun transformer, and discriminator ASIC; and 4) combination of balun transformer and discriminator ASIC. Using two $3{\times } 3{\times }10$ mm 3 fast LGSO crystals side coupled to a linear array of three SiPMs, coincidence data were experimentally acquired for each readout configuration in combination with a low jitter field-programmable gate array (FPGA)-based time-to-digital converter (TDC). After evaluating the timing performance of the three readout schemes, the best CTR value of 99.4 ± 1.9 ps FWHM was achieved for configuration (3), which is more than 20 ps better than the results achieved using configurations (1), (2), and (4).
Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.