Pratik Joshi

Dr. Pratik Joshi

Department of Materials Science and Engineering, NC State University, Raleigh, NC 27695, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2021 in Crystals
Verified
Journal Article
Open access
PDF file
PRParand R. Riley
Parand R. Riley
PJPratik Joshi
Pratik Joshi
Hristo PenchevHristo Penchev
Hristo Penchev
JNJagdish Narayan
Jagdish Narayan
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Finding a low-cost and effective method at low temperatures for producing reduced graphene oxide (rGO) has been the focus of many efforts in the research community for almost two decades. Overall, rGO is a promising candidate for use in supercapacitors, batteries, biosensors, photovoltaic devices, corrosion inhibitors, and optical devices. Herein, we report the formation of rGO from two electrically insulating polymers, polytetrafluoroethylene (PTFE) and meta-polybenzimidazole fiber (m-PBI), using an excimer pulsed laser annealing (PLA) method. The results from X-ray diffraction, scanning electron microscopy, electron backscattered diffraction, Raman spectroscopy, and Fourier-transform infrared spectroscopy confirm the successful generation of rGO with the formation of a multilayered structure. We investigated the mechanisms for the transformation of PTFE and PBI into rGO. The PTFE transition occurs by both a photochemical mechanism and a photothermal mechanism. The transition of PBI is dominated by a photo-oxidation mechanism and stepwise thermal degradation. After degradation and degassing procedures, both the polymers leave behind free molten carbon with some oxygen and hydrogen content. The free molten carbon undergoes an undercooling process with a regrowth velocity (<4 m·s−1) that is necessary for the formation of rGO structures. This approach has the potential for use in creating future selective polymer-written electronics.

13 January 2022 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
PJPratik Joshi
Pratik Joshi
PRParand R. Riley
Parand R. Riley
WDWarren Denning
Warren Denning
SSShubhangi shukla
Shubhangi shukla
NKNayna Khosla
Nayna Khosla
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Medical grade polyethylene-based skeletal implants exhibit osteo-disintegration, erosion, and modest hemocompatibility. Herein, we report on the fabrication of highly adherent undoped and Si-containing DLC (Si-DLC) coatings for biomedical implant applications by utilizing plasma and laser-based processing techniques on thermally sensitive polyethylene (PE) substrates. Scratch testing reveals a strong interfacial shear strength of 620 MPa for DLC coatings deposited on PE. A contact stress of ∼32 MPa induced cracking of the DLC thin film. The Si-DLC films demonstrated a higher critical failure load and less cracking compared to undoped DLC films. The contact angle for PE increased from 90° to 110° when it was coated with the Si-DLC thin film. A high optical bandgap of 2.5 eV was calculated for the 21 at% Si-DLC thin films. Pulsed laser annealing (PLA) of Si-DLC films at 0.3 J cm−2 increased the amount of sp2 bonded carbon, resulting in an improvement in lubricity, hydrophobicity, and electrical conductivity properties. In addition, the laser patterned pristine DLC films showed the formation of reduced graphene oxide, which possessed sizeable properties for wearable electronics and biosensing applications (Rs = 0.6 kΩ □−1). This study indicates that PLA is a useful technique for modifying the properties of DLC thin films on flexible polymeric substrates for state-of-the-art biomedical and electronic sensing applications.

27 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
PJPratik Joshi
Pratik Joshi
PRParand R. Riley
Parand R. Riley
RMRupesh Mishra
Rupesh Mishra
SMSina Azizi Machekposhti
Sina Azizi Machekposhti
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Opioid drugs are extremely potent synthetic analytes, and their abuse is common around the world. Hence, a rapid and point-of-need device is necessary to assess the presence of this compound in body fluid so that a timely countermeasure can be provided to the exposed individuals. Herein, we present an attractive microneedle sensing platform for the detection of the opioid drug fentanyl in real serum samples using an electrochemical detection method. The device contained an array of pyramidal microneedle structures that were integrated with platinum (Pt) and silver (Ag) wires, each with a microcavity opening. The working sensor was modified by graphene ink and subsequently with 4 (3-Butyl-1-imidazolio)-1-butanesulfonate) ionic liquid. The microneedle sensor showed direct oxidation of fentanyl in liquid samples with a detection limit of 27.8 μM by employing a highly sensitive square-wave voltammetry technique. The resulting microneedle-based sensing platform displayed an interference-free fentanyl detection in diluted serum without conceding its sensitivity, stability, and response time. The obtained results revealed that the microneedle sensor holds considerable promise for point-of-need fentanyl detection and opens additional opportunities for detecting substances of abuse in emergencies.

1 January 2021 in Carbon
Verified
Journal Article
Closed access
PJPratik Joshi
Pratik Joshi
AHAriful Haque
Ariful Haque
SGSiddharth Gupta
Siddharth Gupta
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
JNJagdish Narayan
Jagdish Narayan

1 July 2020 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
PJPratik Joshi
Pratik Joshi
BKB. Kombaiah
B. Kombaiah
MCM.N. Cinbiz
M.N. Cinbiz
KMK.L. Murty
K.L. Murty

1 April 2020 in Diamond and Related Materials
Verified
Journal Article
Closed access
PJPratik Joshi
Pratik Joshi
SGSiddharth Gupta
Siddharth Gupta
AHAriful Haque
Ariful Haque
JNJagdish Narayan
Jagdish Narayan