Medical grade polyethylene-based skeletal implants exhibit osteo-disintegration, erosion, and modest hemocompatibility. Herein, we report on the fabrication of highly adherent undoped and Si-containing DLC (Si-DLC) coatings for biomedical implant applications by utilizing plasma and laser-based processing techniques on thermally sensitive polyethylene (PE) substrates. Scratch testing reveals a strong interfacial shear strength of 620 MPa for DLC coatings deposited on PE. A contact stress of ∼32 MPa induced cracking of the DLC thin film. The Si-DLC films demonstrated a higher critical failure load and less cracking compared to undoped DLC films. The contact angle for PE increased from 90° to 110° when it was coated with the Si-DLC thin film. A high optical bandgap of 2.5 eV was calculated for the 21 at% Si-DLC thin films. Pulsed laser annealing (PLA) of Si-DLC films at 0.3 J cm−2 increased the amount of sp2 bonded carbon, resulting in an improvement in lubricity, hydrophobicity, and electrical conductivity properties. In addition, the laser patterned pristine DLC films showed the formation of reduced graphene oxide, which possessed sizeable properties for wearable electronics and biosensing applications (Rs = 0.6 kΩ □−1). This study indicates that PLA is a useful technique for modifying the properties of DLC thin films on flexible polymeric substrates for state-of-the-art biomedical and electronic sensing applications.
Organotrialkoxysilanes like 3-aminopropyltrimethoxysilane (3-APTMS)-treated noble metal cations were rapidly converted into their respective nanoparticles in the presence of 3-glycidoxypropylytrimethoxysilane (3-GPTMS). The micellar activity of 3-APTMS also allowed us to replace 3-GPTMS with other suitable organic reagents (e.g., formaldehyde); this approach has significant advantages for preparing bimetallic and trimetallic analogs of noble metal nanoparticles that display efficient activity in many practical applications. The formation of monometallic gold, silver, and palladium nanoparticles, bimetallic Ag-Pd, and Au-Pd nanoparticles at various ratios of noble metal cations, and trimetallic Ag-Au-Pd nanoparticles were studied; their biocatalytic activity in non-enzymatic sensing of glucose based on monitoring synchronous fluorescence spectroscopy (SFS) was assessed. Of these nanoparticles, Au-Pd made with an 80:20 Au:Pd ratio displayed excellent catalytic activity for glucose sensing. These nanoparticles could also be homogenized with Nafion to enhance the resonance Rayleigh scattering (RRS) signal. In this study, the structural characterization of noble metal nanoparticles as well as bi- and tri-metallic nanoparticles in addition to their use in non-enzymatic sensing of glucose are reported.
Nitric oxide (NO) signaling plays many pivotal roles impacting almost every organ function in mammalian physiology, most notably in cardiovascular homeostasis, inflammation, and neurological regulation. Consequently, the ability to make real-time and continuous measurements of NO is a prerequisite research tool to understand fundamental biology in health and disease. Despite considerable success in the electrochemical sensing of NO, challenges remain to optimize rapid and highly sensitive detection, without interference from other species, in both cultured cells and in vivo. Achieving these goals depends on the choice of electrode material and the electrode surface modification, with graphene nanostructures recently reported to enhance the electrocatalytic detection of NO. Due to its single-atom thickness, high specific surface area, and highest electron mobility, graphene holds promise for electrochemical sensing of NO with unprecedented sensitivity and specificity even at sub-nanomolar concentrations. The non-covalent functionalization of graphene through supermolecular interactions, including π–π stacking and electrostatic interaction, facilitates the successful immobilization of other high electrolytic materials and heme biomolecules on graphene while maintaining the structural integrity and morphology of graphene sheets. Such nanocomposites have been optimized for the highly sensitive and specific detection of NO under physiologically relevant conditions. In this review, we examine the building blocks of these graphene-based electrochemical sensors, including the conjugation of different electrolytic materials and biomolecules on graphene, and sensing mechanisms, by reflecting on the recent developments in materials and engineering for real-time detection of NO in biological systems.
Selective screening followed by the sensing of cesium radionuclides from contaminated water is a challenging technical issue. In this study, the adsorption functionality of Prussian blue (PB) nanoparticles was utilized for the detection and efficient removal of cesium cations. An efficient PB nanoparticle-modified screen-printed electrode (SPE) in the three-electrode configuration was developed for the electrochemical sensing and removal of Cs+. PB nanoparticles inks were obtained using a facile two-step process that was previously described as suitable for dispensing over freshly prepared screen-printed electrodes. The PB nanoparticle-modified SPE induced a cesium adsorption-dependent chronoamperometric signal based on ion exchange as a function of cesium concentration. This ion exchange, which is reversible and rapid, is associated with electron transfer in the PB nanoparticle-modified SPE. Using this electrochemical adsorption system (EAS) based on chronoamperometry, the maximum adsorption capacity (Qmax) of Cs+ ions in the PB nanoparticle-modified SPE reached up to 325 ± 1 mg·g−1 in a 50 ± 0.5 μM Cs+ solution, with a distribution coefficient (Kd) of 580 ± 5 L·g−1 for Cs+ removal. The cesium concentration-dependent adsorption of PB nanoparticles was also demonstrated by fluorescence spectroscopy based on fluorescence quenching of PB nanoparticles as a function of cesium concentration using a standard fluorophore like fluorescein in a manner analogous to that previously reported for As(III).
Prussian blue nanoparticles (PBN) exhibit selective fluorescence quenching behavior with heavy metal ions; in addition, they possess characteristic oxidant properties both for liquid–liquid and liquid–solid interface catalysis. Here, we propose to study the detection and efficient removal of toxic arsenic(III) species by materializing these dual functions of PBN. A sophisticated PBN-sensitized fluorometric switching system for dosage-dependent detection of As3+ along with PBN-integrated SiO2 platforms as a column adsorbent for biphasic oxidation and elimination of As3+ have been developed. Colloidal PBN were obtained by a facile two-step process involving chemical reduction in the presence of 2-(3,4-epoxycyclohexyl)ethyl trimethoxysilane (EETMSi) and cyclohexanone as reducing agents, while heterogeneous systems were formulated via EETMSi, which triggered in situ growth of PBN inside the three-dimensional framework of silica gel and silica nanoparticles (SiO2). PBN-induced quenching of the emission signal was recorded with an As3+ concentration (0.05–1.6 ppm)-dependent fluorometric titration system, owing to the potential excitation window of PBN (at 480–500 nm), which ultimately restricts the radiative energy transfer. The detection limit for this arrangement is estimated around 0.025 ppm. Furthermore, the mesoporous and macroporous PBN-integrated SiO2 arrangements might act as stationary phase in chromatographic studies to significantly remove As3+. Besides physisorption, significant electron exchange between Fe3+/Fe2+ lattice points and As3+ ions enable complete conversion to less toxic As5+ ions with the repeated influx of mobile phase. PBN-integrated SiO2 matrices were successfully restored after segregating the target ions. This study indicates that PBN and PBN-integrated SiO2 platforms may enable straightforward and low-cost removal of arsenic from contaminated water.