Vahidin Hadžiabdić

Prof. Dr. Vahidin Hadžiabdić

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LVLejla Redzepagic - Vrazalica
Lejla Redzepagic - Vrazalica
EMElmedin Mešić
Elmedin Mešić
NPNedim Pervan
Nedim Pervan
VHVahidin Hadžiabdić
Vahidin Hadžiabdić
MDMuamer Delić
Muamer Delić
MGMirza Glusac
Mirza Glusac
This study investigated the correlation between bone characteristics, the design of orthodontic mini-implants, the pull-out force, and primary stability. This experimental in vitro study has examined commercial orthodontic mini-implants of different sizes and designs, produced by two manufacturers: Tomas-pin SD (Dentaurum, Ispringen, Germany) and Perfect Anchor (Hubit, Seoul, Korea). The total number of 40 mini-implants were tested. There are two properties that are common to all tested implants—one is the material of which they are made (titanium alloy Ti-6Al-4V), and the other is the method of their insertion. The main difference between the mini-implants, which is why they have been selected as the subject of research in the first place, is reflected in their geometry or design. Regardless of the type of implant, the average pull-out forces were found to be higher for a cortical bone thickness (CBTC) of 0.62–0.67 mm on average, compared to the CBTC < 0.62 mm, where the measured force averages were found to be lower. The analysis of variance tested the impact of the mini-implant geometry on the pull-out force and proved that there is a statistically significant impact (p < 0.015) of all three analyzed geometric factors on the pull-out force of the implant. The design of the mini-implant affects its primary stability. The design of the mini-implant affects the pulling force. The bone quality at the implant insertion point is important for primary stability; thus, the increase in the cortical bone thickness increases the value of the pulling force significantly.

1 December 2014 in Advances in Difference Equations
Verified
Journal Article
Open access
PDF file
VHVahidin Hadžiabdić
Vahidin Hadžiabdić
Mustafa KulenovicMustafa Kulenovic
Mustafa Kulenovic
EPEsmir Pilav
Esmir Pilav
We investigate global dynamics of the following systems of difference equations:{xn+1=b1xn2A1+yn2,yn+1=a2+c2yn2xn2,n=0,1,2,…,where the parametersb1,a2,A1,c2are positive numbers and the initial conditiony0is an arbitrary nonnegative number andx0is a positive number. We show that this system has rich dynamics which depends on the part of a parametric space. We find precisely the basins of attraction of all attractors including the points at ∞.MSC:39A10, 39A30, 37E99, 37D10.

12 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Adis MuminovicAdis Muminovic
Adis Muminovic
Łukasz GierzŁukasz Gierz
Łukasz Gierz
HRHasan Rebihić
Hasan Rebihić
JSJasmin Smajic
Jasmin Smajic
NPNedim Pervan
Nedim Pervan
MSMaciej Sydor
Maciej Sydor
Product design and manufacturing leverage 3D scanning for various applications. This study aims to investigate the effectiveness of 3D scanning in furniture production by surveying the literature and showcasing four real-world case studies. The literature review reveals that 3D data acquired from real-world objects have applications in research, rapid prototyping, restoration, and preservation of antique furniture, optimizing CNC machining processes, and measuring furniture components for quality control. The case study descriptions demonstrated the circumstances, rationale, and methodology for 3D scanning. All the case studies analyzed stem from the collaboration between the Laboratory for Product Development and Design at the Faculty of Mechanical Engineering at the University of Sarajevo and various furniture production enterprises from Bosnia and Herzegovina. The conclusions highlight that 3D scanning in the furniture sector is advantageous for developing computer-aided design models from early-stage design prototypes, validating the dimensional accuracy of manufactured components by comparing with CAD models, safeguarding and reconstructing vintage furniture, and remanufacturing formerly produced goods that lack complete technical records (reverse engineering).

12 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NPNedim Pervan
Nedim Pervan
EMElmedin Mešić
Elmedin Mešić
Adis MuminovicAdis Muminovic
Adis Muminovic
MDMuamer Delić
Muamer Delić
Enis MuratovićEnis Muratović
Enis Muratović
VHVahidin Hadžiabdić
Vahidin Hadžiabdić
This paper describes comparative analysis of the biomechanical performances conducted on the external fixation devices whose frames are made out of two different material (stainless steel and composite material). Biomechanical properties were determined with experimental and FEM (finite element method) models which are used to study the movement of the fracture crack, establish stiffness of the design solutions and monitor generated stresses on the zones of interest. Geometric modeling of two fixation devices configurations B50 and C50 is used as a basis for structural analysis under the impact of axial load. Structural analysis results are confirmed with an experimental setup. Analyzed deflection values in the load and fracture zones are used to define the exact values of the stiffness for the construction design and fracture, respectively. The carbon frame device configuration has 28% lower construction stiffness than the one with the steel frame (for B50 configuration), i.e., 9% (for C50 configuration). In addition, fracture stiffness values for the composite frame application are approximately 23% lower (B50 configuration), i.e., 13% lower (C50 configuration), compared to steel frame. The carbon frame device has about 33% lower stresses at the critical zones compared to the steel frame at the control zone MM+ and, similarly, 35% lower stresses at the control zone MM-. With an exhausting analysis of the biomechanical properties of the fixation devices, it can be concluded that steel frame fixation device is superior, meaning it has better biomechanical characteristics compared to carbon frame fixation device, regarding obtained data for stresses and stiffnesses of the frame construction and fracture. Considering stresses at the critical zones of the fixation device construction, the carbon frame device has better biomechanical performances compared to steel frame devices.

12 May 2021
Verified
Book Chapter
Closed access
PDF file
ZIZejd Imamović
Zejd Imamović
VHVahidin Hadžiabdić
Vahidin Hadžiabdić
MMMidhat Mehuljić
Midhat Mehuljić
JBJasmin Bektešević
Jasmin Bektešević
DBDževad Burgić
Dževad Burgić

26 May 2022
Verified
Book Chapter
Closed access
PDF file
JBJasmin Bektešević
Jasmin Bektešević
VHVahidin Hadžiabdić
Vahidin Hadžiabdić
MMMidhat Mehuljić
Midhat Mehuljić
AMAdnan Mašić
Adnan Mašić