Elmedin Mešić

Prof. Dr. Elmedin Mešić

University of Sarajevo, Faculty of Mechanical Engineering
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2023 in Polymers
Verified
Journal Article
Open access
PDF file
VJVedran Jakupović
Vedran Jakupović
NPNedim Pervan
Nedim Pervan
EMElmedin Mešić
Elmedin Mešić
AGAlma Gavranović-Glamoč
Alma Gavranović-Glamoč
ABAnita Bajsman
Anita Bajsman
AKAlma Kantardžić-Kovačević
Alma Kantardžić-Kovačević
(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm2) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm2) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.

28 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LVLejla Redzepagic - Vrazalica
Lejla Redzepagic - Vrazalica
EMElmedin Mešić
Elmedin Mešić
NPNedim Pervan
Nedim Pervan
VHVahidin Hadžiabdić
Vahidin Hadžiabdić
MDMuamer Delić
Muamer Delić
MGMirza Glusac
Mirza Glusac
This study investigated the correlation between bone characteristics, the design of orthodontic mini-implants, the pull-out force, and primary stability. This experimental in vitro study has examined commercial orthodontic mini-implants of different sizes and designs, produced by two manufacturers: Tomas-pin SD (Dentaurum, Ispringen, Germany) and Perfect Anchor (Hubit, Seoul, Korea). The total number of 40 mini-implants were tested. There are two properties that are common to all tested implants—one is the material of which they are made (titanium alloy Ti-6Al-4V), and the other is the method of their insertion. The main difference between the mini-implants, which is why they have been selected as the subject of research in the first place, is reflected in their geometry or design. Regardless of the type of implant, the average pull-out forces were found to be higher for a cortical bone thickness (CBTC) of 0.62–0.67 mm on average, compared to the CBTC < 0.62 mm, where the measured force averages were found to be lower. The analysis of variance tested the impact of the mini-implant geometry on the pull-out force and proved that there is a statistically significant impact (p < 0.015) of all three analyzed geometric factors on the pull-out force of the implant. The design of the mini-implant affects its primary stability. The design of the mini-implant affects the pulling force. The bone quality at the implant insertion point is important for primary stability; thus, the increase in the cortical bone thickness increases the value of the pulling force significantly.

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
EMElmedin Mešić
Elmedin Mešić
AVAvdić Vahid
Avdić Vahid
NPNedim Pervan
Nedim Pervan
RNRepčić Nedžad
Repčić Nedžad
This paper presents research results of a stiffness analysis of a Sarafix external fixation system. The stiffness property of the external fixator affects the local biomechanical and biological environment of fracture healing. The research has been conducted in a case when one of the Sarafix unilateral biplanar fixator configurations has been applied to a tibia with an open fracture. A stiffness analysis was performed using FEA and experimental testing under three types of loads: axial compression, AP (anterior-posterior) four-point bending and torsion. 3D geometrical and FEM model of the fixator configuration was formed using CATIA V5 software system and a structural analysis was performed afterwards. Verification of the results obtained from a structural analysis was carried out through experimental testing by comparing values of an appropriate component of displacement at the point of load

28 August 2019 in TEM Journal
Verified
Journal Article
Open access
Adis MuminovicAdis Muminovic
Adis Muminovic
AMAdil Muminovic
Adil Muminovic
EMElmedin Mešić
Elmedin Mešić
Isad ŠarićIsad Šarić
Isad Šarić
NPNedim Pervan
Nedim Pervan
There is a lot of papers concerning gears topology optimization, but all of them are limited to the topology optimization of gear body. Gear tooth is not taken into consideration so far. Gear tooth was not optimized before because optimised structure could not be produced. By advancing of additive manufacturing technology, now, gear tooth can be produced in a form of shell body with empty space inside. In this paper, mass of spur gear tooth is optimized in relation to Von- Misses stress on critical places on the gear tooth. Optimization goal is to find optimal shell thickness of shell body spur gear tooth.

27 June 2019 in Periodicals of Engineering and Natural Sciences (PEN)
Verified
Journal Article
Open access
PDF file
Adis MuminovicAdis Muminovic
Adis Muminovic
Isad ŠarićIsad Šarić
Isad Šarić
EMElmedin Mešić
Elmedin Mešić
NPNedim Pervan
Nedim Pervan
MDMuamer Delić
Muamer Delić
Research about characteristics of designs from industrial designers and product designers

26 November 2015 in TEM Journal
Verified
Journal Article
Open access
PDF file
NPNedim Pervan
Nedim Pervan
EMElmedin Mešić
Elmedin Mešić
MCMirsad Colic
Mirsad Colic
VAVahid Avdic
Vahid Avdic
This paper describes a structural analysis of the CAD model three versions fixators Sarafix which is to explore the possibility of introducing composite materials in the construction of the connecting rod fixators comparing values of displacement and stiffness at characteristic structure points. Namely, we have investigated the constructional performance of fixators Sarafix with a connecting rod formed from three different composite materials, the same matrix (epoxy resin) with three different types of fibers (E glass, kevlar 49 and carbonM55J). The results of the structural analysis fixators Sarafix with a connecting rod made of composite materials are compared with the results of tubular connecting rod fixators made of stainless steel. After comparing the results, from the aspect of stiffness, we gave the final considerations about composite material which provides an adequate substitution for the existing material.