View All Publications
1 January 2023 in Annals of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Open access
PDF file
GCGiorgia Colarossi
Giorgia Colarossi
FMFilippo Migliorini
Filippo Migliorini
MBMichael Becker
Michael Becker
JAJessica P Arias
Jessica P Arias
RARuediger Autschbach
Ruediger Autschbach
AAAli Aljalloud
Ali Aljalloud
Purpose: Perceval sutureless valves have gained popularity. Whether this implant performs superior to the traditional sutured prosthesis remains unclear. This meta- analysis compared the Perceval implants versus the sutured conventional valves for aortic valve replacement (AVR).Methods: This meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were accessed: PubMed, Google Scholar, Web of Science, Scopus, and EMBASE. All clinical investigations comparing Perceval versus the conventional prostheses for AVR were considered.Results: The Perceval group demonstrated higher rate of pacemaker implantation (P <0.00001). Aortic cross-clamp (ACC) time (P <0.00001) and cardiopulmonary bypass (CPB) time (P <0.00001) were shorter in the Perceval group. Similarity was found in mean and peak pressure gradient (P = 0.8 and P = 0.2, respectively), mean aortic valve area (P = 0.3), length of intensive care unit (P = 0.4) and hospital stay (P = 0.2), rate of revision (P = 0.11), hemorrhages (P = 0.05), paravalvular leak (P = 0.3), cerebrovascular complication (P = 0.7), and early mortality (P = 0.06).Conclusion: Given the shorter ACC time and CPB time, Perceval AVR can be an alternative in high-risk patients. The higher rate of pacemaker implantation following Perceval may limit its routine implantation.

24 February 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CFChristina Feldmann
Christina Feldmann
RZRashad Zayat
Rashad Zayat
AGAndreas Goetzenich
Andreas Goetzenich
AAAli Aljalloud
Ali Aljalloud
EWEva Woelke
Eva Woelke
AMAjay Moza
Ajay Moza
Acquired von Willebrand syndrome (AvWS) is associated with postoperative bleeding complications in patients with continuous flow left ventricular assist devices (CF-LVADs). The aim of this study is to analyze the perioperative vWF profile comparing an axial pump (HMII) to a centrifugal pump (HVAD) regarding the correlation between perioperative occurrence of AvWS, early- and late-postoperative bleeding events. From July 2013 until March 2015 blood samples of 33 patients (12 HMII/ 8 HVAD/ 13 controls) were prospectively collected at 12 different time points and analyzed for the vWF antigen (vWF:Ag), its activity (vWF:Ac) and the vWF:Ac/vWF:Ag-ratio (vWF:ratio). The follow up period for postoperative bleeding events was from July 2013 until July 2016. Postoperatively, there was no difference in the vWF-profile between HVAD and HMII groups. However, a subgroup of patients already had significantly lower vWF:ratios preoperatively. Postoperatively, both CF-LVAD groups presented significantly lower vWF:ratios compared to the control group. Bleeding events per patient-year did not differ between the two groups (HMII vs. HVAD: 0.67 vs. 0.85, p = 0.685). We detected a correlation between vWF:ratio <0.7at LVAD-start (r = -0.583, p = 0.006) or at the end of surgery (r = -0.461, p = 0.035) and the occurrence of pericardial tamponade. In the control group, the drop in both vWF:Ag and vWF:Ac recovered immediately postoperatively above preoperative values. A subgroup of patients with end-stage heart failure already suffers AvWS preoperatively. In both CF-LVAD groups, AvWS begins immediately after surgery. Intraoperative vWF:ratios <0.7 correlate with higher incidences of pericardial tamponade and re-operation. The presumably dilutive effect of the heart lung machine on vWF vanishes immediately at the end of surgery, possibly as part of an acute-phase response.

17 May 2018 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
AAAli Aljalloud
Ali Aljalloud
MSMohamed Shoaib
Mohamed Shoaib
SESandrine Egron
Sandrine Egron
JAJessica Arias
Jessica Arias
LTLachmandath Tewarie
Lachmandath Tewarie
RARuediger Autschbach
Ruediger Autschbach
Sutureless aortic valve prostheses are gaining popularity due to the substantial reduction in cross-clamp time. In this study, we report our observations on the cusp-fluttering phenomenon of the Perceval bioprosthesis (LivaNova, London, UK) using a combination of technical and medical perspectives. Between August 2014 and December 2016, a total of 108 patients (69% women) with a mean age of 78 years had aortic valve replacement using the Perceval bioprosthesis (34 combined procedures). All patients underwent transoesophageal echocardiography (TOE) intraoperatively. TOE was performed postoperatively to detect paravalvular leakage and to measure gradients, acceleration time, Doppler velocity indices (Vmax and LVOT/Vmax AV) and effective orifice area indices. In addition, a TOE examination was performed in 21 patients postoperatively. Data were collected retrospectively from our hospital database. The retrospective evaluation of the intraoperative TOE examinations revealed consistent fluttering in all patients with the Perceval bioprosthesis. The echocardiographic postoperative measurements showed a mean effective orifice area index of 0.91 ± 0.12 cm2/m2. The overall mean pressure and peak pressure gradients were in a higher range (13.5 ± 5.1 mmHg and 25.5 ± 8.6 mmHg, respectively), whereas acceleration time (62.8 ± 16.4 ms) and Doppler velocity indices (0.43 ± 0.11) were within the normal range according to the American Society of Echocardiography or european association of echocardiography (EAE) guidelines. The 2-dimensional TOE in Motion Mode (M-Mode) that was performed in patients with elevated lactate dehydrogenase (LDH) levels revealed remarkable fluttering of the cusps of the Perceval bioprosthesis. In our study cohort, we observed the fluttering phenomenon in all patients who received the Perceval bioprosthesis, which was correlated with elevated LDH levels and higher pressure gradients.

6 March 2024 in Clinical Cardiology
Verified
Journal Article
Open access
AEAngelika Eichelmann
Angelika Eichelmann
RKRalf Kubini
Ralf Kubini
DNDejan Nachoski
Dejan Nachoski
CKChristoph Kosinski
Christoph Kosinski
MBMichael Becker
Michael Becker
AAAli Aljalloud
Ali Aljalloud
Background: The advantages of patent foramen ovale (PFO) closure as protection from a recurrence of stroke remains controversial compared to drug therapy, especially in patients over 60 years.Hypothesis: The aim of the study is to compare recurrence of stroke in patients over 60 years old with PFO closure versus drug therapy alone.Methods: We included 342 patients over 60 years who suffered a crytopgenic stroke, and were also accepted for a PFO closure. 199 patients refused a PFO closure and were treated with medical therapy alone, whereas 143 patients underwent a PFO closure procedure.Results: The mean follow up time was 5.5 ± 1.5 years. All patients in Group B showed persistent shunt in the follow‐up period (n = 199, 100%). In Group A, seven patients were diagnosed with residual shunt during echocardiography examination (5%). A new onset of atrial fibrillation occurred in seven patients in Group A (5%) and six patients in Group B (3%), p = .117. Recurrent stroke occurred in 3 patients in Group A (2%) and 11 patients in Group B (6%), p = .021. One patient died of unknown reason (1%) and two patients were lost due to neurological death (1%) in Group B, whereas no patients in Group A died during the follow‐up period.Conclusion: Our results show that strict exclusion of patients over 60 years from PFO closure should be reconsidered. As life expectancies are increasing, patients should be considered for same treatment as younger patients, since the outcomes are improved compared to patients treated with medical therapy alone.

24 June 2014 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
NHNima Hatam
Nima Hatam
AAAli Aljalloud
Ali Aljalloud
KMKarl Mischke
Karl Mischke
EKElias A Karfis
Elias A Karfis
RARüdiger Autschbach
Rüdiger Autschbach
AGAndreas Goetzenich
Andreas Goetzenich
Disturbances of interatrial conduction have been proposed as one of the contributing mechanisms of postoperative atrial fibrillation (AF). P-wave dispersion has been recognized as a sensitive tool for detecting interatrial conduction disturbances. Doppler myocardial imaging (DMI) has been validated as a non-invasive tool to indirectly reflect electrical atrial activation and therefore is used in this study to detect possible interatrial electromechanical disturbances after cardiac surgery. 30 patients (23 men, age 62 ± 1 years) admitted for coronary bypass surgery with no prior history of AF were included in this investigation. Echocardiography and electrocardiograms (ECG) were obtained on the day before and after surgery. In addition to standard echocardiography, DMI-loops were acquired from the apical window. The following time intervals were derived off-line from the free right atrial (RA), left atrial (LA) lateral and LA posterior wall: onset P-wave to start (P to A'start), to peak (P to A'peak) and to end of atrial deformation (total electromechanical activity). These intervals were compared to each other and to P-wave dispersion derived from the recorded ECGs. All patients were in sinus rhythm during their postoperative assessment, but 11 patients presented episodes of AF within the first three postoperative days. Atrial electromechanical activation was earliest in the RA and latest in the lateral LA. In patients with AF, P-wave dispersion was significantly prolonged postoperatively (mean: +18.6 ms; 95% confidence interval (CI): 12.1-25.2 ms; p < 0.001) compared to non-AF patients (mean: -2.4 ms; CI: -6.6-1.9 ms). P dispersion was closely correlated to P to A'start intervals (from RA to LA lat.: preop.: rho = 0.74, postop.: rho = 0.87; p < 0.001). Prolonged right to left conduction interval was associated with an elevated risk for AF (from RA to LA lat.: odds ratio 1.13 (CI:1.03-1.24); p: 0.007. DMI enabled detection of interatrial conduction disturbances in concordance to findings of prolonged postoperative P-wave dispersion. Equally effective to P-wave dispersion, this simple and reproducible tool might help to early identify the risk for postoperative AF, thus extending the informative value of routine postoperative echocardiography.

Verified
Journal Article
Open access
PDF file
AAAli Aljalloud
Ali Aljalloud
AMAjay Moza
Ajay Moza
JAJessica Paola Arias
Jessica Paola Arias
MMMatthias Menne
Matthias Menne
MBMichael Becker
Michael Becker
KSKonstantina Spetsotaki
Konstantina Spetsotaki
Purpose: The benefits of sutureless compared to conventional aortic valve prosthesis replacement remain controversial. Supposed advantages of sutureless aortic valve replacement include shortened cross-clamp and implantation time, as well as improved overall safety and good post-operative performance. We aimed to compare the early outcomes and performance of sutureless aortic valve replacement (su-AVR) with the sutureless Perceval (Corcym, Milan, Italy) vs. the conventional AVR with a conventional counterpart, in this case, the Labcor Dokimos Plus (LDP) aortic bioprosthesis. Methods: We compared two types of aortic valve prostheses, the sutureless (Corcym, Milan, Italy) and the conventional valve Labcor Dokimos Plus (LDP), implanted between August 2014 and May 2019 in our Department of Cardiac Surgery at RWTH Aachen University Hospital. Data were collected from 141 patients who received the Perceval (Corcym, Milan, Italy) and 138 who received the Labcor Dokimos Plus (LDP) aortic bioprosthesis. After matching the two groups considering STS mortality risk and pre-operative LDH levels, 201 patients were included in our final study cohort. Seventy-one patients (17 from the Perceval group and 54 from the Dokimos group) were excluded due to the lack of complete data, particularly standardized echocardiographic data (n = 71). Primary endpoints were 30-day mortality, length of hospital stay, and pacemaker implantation. Secondary endpoints were echocardiographic parameters, major adverse cardiovascular events, and prosthesis failure (grade II aortic regurgitation, paravalvular leak with reintervention). Results: Bypass and cross-clamp time proved to be shorter in the Perceval group, while hospital stays were longer. The faster implantation had no effect on the 30-day mortality primary endpoint. Transvalvular gradients were significantly higher in the Perceval group, in addition to a smaller effective orifice area. The LDH values were remarkably higher post-operatively in the Perceval group. Conclusions: Regarding the clinical outcomes, Perceval was equivalent and not superior to the Dokimus bioprosthesis. The suitability of a Perceval prosthesis implantation must be determined on a case-by-case basis and reserved for elderly patients with increased comorbidity.