Julia Behnsen

Dr. Julia Behnsen

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Journal of Geophysical Research: Solid Earth
Verified
Journal Article
Open access
PDF file
JBJulia Behnsen
Julia Behnsen
DFD. R. Faulkner
D. R. Faulkner
Smectites, such as montmorillonite, are abundant throughout the upper crust and are commonly found in fault gouge. They are known for their weak frictional strength and low permeability. Smectites are swellable clays in which the interlayer cation can easily be exchanged. In this study, we measure permeability and frictional strength of montmorillonite exchanged with Na+, K+, Ca2+, and Mg2+ using a triaxial shear apparatus. We find that the interlayer cation influences both permeability and the friction coefficient. K‐montmorillonite is significantly stronger (μ=0.26) than Na‐montmorillonite (μ=0.15) and Ca‐ or Mg‐montmorillonite (μ=0.11). Permeability for all four clays is between 10−21 and 10−23 m2 in the pressure range between 10 MPa and 100 MPa, with K‐montmorillonite the most permeable clay gouge. Mg‐, Ca‐, and Na‐montmorillonite show relative similar permeabilities of which Na‐montmorillonite is least permeable. We relate the higher frictional strength and permeability of K‐montmorillonite to reduce interlayer water content caused by differences in cation hydration and adsorption. The results show that the rapid cation exchange process in montmorillonite can influence macroscale parameters, such as permeability and strength, which can contribute to changes in local pressure conditions and frictional strength of shallow fault zones.

1 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
JBJulia Behnsen
Julia Behnsen
KBKate Black
Kate Black
JHJames Houghton
James Houghton
RWRichard H. Worden
Richard H. Worden
Particle size and morphology analysis is a problem common to a wide range of applications, including additive manufacturing, geological and agricultural materials’ characterisation, food manufacturing and pharmaceuticals. Here, we review the use of microfocus X-ray computed tomography (X-ray CT) for particle analysis. We give an overview of different sample preparation methods, image processing protocols, the morphology parameters that can be determined, and types of materials that are suitable for analysis of particle sizes using X-ray CT. The main conclusion is that size and shape parameters can be determined for particles larger than approximately 2 to 3 μm, given adequate resolution of the X-ray CT setup. Particles composed of high atomic number materials (Z > 40) require careful sample preparation to ensure X-ray transmission. Problems occur when particles with a broad range of sizes are closely packed together, or when particles are fused (sintered or cemented). The use of X-ray CT for particle size analysis promises to become increasingly widespread, offering measurements of size, shape, and porosity of large numbers of particles within one X-ray CT scan.

1 May 2021 in Composites Part B: Engineering
Verified
Journal Article
Closed access
MAMonica Alberto
Monica Alberto
MIMaria Iliut
Maria Iliut
MPMohan Kumar Pitchan
Mohan Kumar Pitchan
JBJulia Behnsen
Julia Behnsen
AVAravind Vijayaraghavan
Aravind Vijayaraghavan

15 March 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
AKAlireza Karimi
Alireza Karimi
DCDevon Jacob Crouch
Devon Jacob Crouch
RRReza Razaghi
Reza Razaghi
JDJ. Crawford Downs
J. Crawford Downs
TATed S. Acott
Ted S. Acott
Carl SheridanCarl Sheridan
Carl Sheridan
Intraocular pressure (IOP) is maintained via a dynamic balance between the production of aqueous humor and its drainage through the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) endothelium of the conventional outflow pathway. Primary open angle glaucoma (POAG) is often associated with IOP elevation that occurs due to an abnormally high outflow resistance across the outflow pathway. Outflow tissues are viscoelastic and actively interact with aqueous humor dynamics through a two-way fluid-structure interaction coupling. While glaucoma affects the morphology and stiffness of the outflow tissues, their biomechanics and hydrodynamics in glaucoma eyes remain largely unknown. This research aims to develop an image-to-model method allowing the biomechanics and hydrodynamics of the conventional aqueous outflow pathway to be studied. We used a combination of X-ray computed tomography and scanning electron microscopy to reconstruct high-fidelity, eye-specific, 3D microstructural finite element models of the healthy and glaucoma outflow tissues in cellularized and decellularized conditions. The viscoelastic TM/JCT/SC complex finite element models with embedded viscoelastic beam elements were subjected to a physiological IOP load boundary; the stresses/strains and the flow state were calculated using fluid-structure interaction and computational fluid dynamics. Based on the resultant hydrodynamics parameters across the outflow pathway, the primary site of outflow resistance in healthy eyes was in the JCT and immediate vicinity of the SC inner wall, while the majority of the outflow resistance in the glaucoma eyes occurred in the TM. The TM and JCT in the glaucoma eyes showed 1.32-fold and 1.13-fold larger beam thickness and smaller trabecular space size (2.24-fold and 1.50-fold) compared to the healthy eyes. Characterizing the accurate morphology of the outflow tissues may significantly contribute to constructing more accurate, robust, and reliable models, that can eventually help to better understand the dynamic IOP regulation, hydrodynamics of the aqueous humor, and outflow resistance dynamic in the human eyes. This model demonstrates proof of concept for determining changes to outflow resistance in healthy and glaucomatous tissues and thus may be utilized in larger cohorts of donor tissues where disease specificity, race, age, and gender of the eye donors may be accounted for.

Verified
Journal Article
Open access
PDF file
SBSamantha Borland
Samantha Borland
JBJulia Behnsen
Julia Behnsen
NANick Ashton
Nick Ashton
SFSheila E. Francis
Sheila E. Francis
KBKeith Brennan
Keith Brennan
ACAnn E. Canfield
Ann E. Canfield
Vascular calcification describes the formation of mineralized tissue within the blood vessel wall, and it is highly associated with increased cardiovascular morbidity and mortality in patients with chronic kidney disease, diabetes, and atherosclerosis. In this article, we briefly review different rodent models used to study vascular calcification in vivo, and critically assess the strengths and weaknesses of the current techniques used to analyze and quantify calcification in these models, namely 2-D histology and the o-cresolphthalein assay. In light of this, we examine X-ray micro-computed tomography (µCT) as an emerging complementary tool for the analysis of vascular calcification in animal models. We demonstrate that this non-destructive technique allows us to simultaneously quantify and localize calcification in an intact vessel in 3-D, and we consider recent advances in µCT sample preparation techniques. This review also discusses the potential to combine 3-D µCT analyses with subsequent 2-D histological, immunohistochemical, and proteomic approaches in correlative microscopy workflows to obtain rich, multifaceted information on calcification volume, calcification load, and signaling mechanisms from within the same arterial segment. In conclusion we briefly discuss the potential use of µCT to visualize and measure vascular calcification in vivo in real-time.

22 September 2023 in Journal of Functional Biomaterials
Verified
Journal Article
Open access
PDF file
DCDevon Jacob Crouch
Devon Jacob Crouch
Carl SheridanCarl Sheridan
Carl Sheridan
JBJulia Behnsen
Julia Behnsen
RDRaechelle A. D’sa
Raechelle A. D’sa
LBLucy Bosworth
Lucy Bosworth
Human trabecular meshwork is a sieve-like tissue with large pores, which plays a vital role in aqueous humor outflow. Dysfunction of this tissue can occur, which leads to glaucoma and permanent vision loss. Replacement of trabecular meshwork with a tissue-engineered device is the ultimate objective. This study aimed to create a biomimetic structure of trabecular meshwork using electrospinning. Conventional electrospinning was compared to cryogenic electrospinning, the latter being an adaptation of conventional electrospinning whereby dry ice is incorporated in the fiber collector system. The dry ice causes ice crystals to form in-between the fibers, increasing the inter-fiber spacing, which is retained following sublimation. Structural characterization demonstrated cryo-scaffolds to have closer recapitulation of the trabecular meshwork, in terms of pore size, porosity, and thickness. The attachment of a healthy, human trabecular meshwork cell line (NTM5) to the scaffold was not influenced by the fabrication method. The main objective was to assess cell infiltration. Cryo-scaffolds supported cell penetration deep within their structure after seven days, whereas cells remained on the outer surface for conventional scaffolds. This study demonstrates the suitability of cryogenic electrospinning for the close recapitulation of trabecular meshwork and its potential as a 3D in vitro model and, in time, a tissue-engineered device.