Felipe Pauchard

Dr. Felipe Pauchard

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
FPFelipe Pauchard
Felipe Pauchard
Eugenio VentimigliaEugenio Ventimiglia
Eugenio Ventimiglia
MCMariela Corrales
Mariela Corrales
Olivier TraxerOlivier Traxer
Olivier Traxer
Introduction: One of the main limitations of Ho:YAG lithotripsy is represented by its advancement speed. The need for faster lithotripsy has led to the introduction of high-power laser equipment. This general trend in increasing Ho:YAG lithotripsy power has certain points that deserve to be considered and analyzed. The objective is to carry out a narrative review on intrarenal temperature and pressure during ureteroscopy. Methods: A literature search using PUBMED database from inception to December 2021 was performed. The analysis involved a narrative synthesis. Results: Using more power in the laser correlates with an increase in temperature that can be harmful to the kidney. This potential risk can be overcome by increasing either the irrigation inflow or outflow. Increasing irrigant flow can lead to high intrarenal temperature (IRP). The factors that allow the reduction of intrarenal pressure are a low irrigation flow, the use of a ureteral access sheath of adequate diameter according to the equipment used, and the occupation of the working channel by the laser or basket. Conclusion: To maintain a safe temperature profile, it has been proposed to use chilled irrigation fluid, intermittent laser activation or to increase irrigation flow. This last recommendation can lead to increased IRP, which can be overcome by using a UAS. Another option is to use low power laser configurations in order to avoid temperature increases and not require high irrigation flows.

1 August 2021 in Journal of Endourology
Verified
Journal Article
Closed access
Eugenio VentimigliaEugenio Ventimiglia
Eugenio Ventimiglia
FPFelipe Pauchard
Felipe Pauchard
FQFrancesca Quadrini
Francesca Quadrini
SSSermsin Sindhubodee
Sermsin Sindhubodee
HKHatem Kamkoum
Hatem Kamkoum
Olivier TraxerOlivier Traxer
Olivier Traxer
Purpose: There is no clear evidence that high-power (HP) laser generators perform better than low-power (LP) ones in terms of lithotripsy outcomes. We aimed to perform a systematic review of literature to compare the efficacy outcomes of both HP and LP during ureteroscopic lithotripsy. Materials and Methods: A computerized bibliographic search of the Medline, Embase, and Cochrane databases was performed for all studies reporting perioperative outcomes of HP and LP lithotripsy. Using the methodology recommended by the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines, we identified 22 nonrandomized noncomparative retrospective studies published between 2015 and 2019 that were eligible for inclusion in this systematic review. Because of the lack of comparative studies, we decided to perform two separate meta-analytic syntheses for LP and HP studies, then we compared them using a Wald-type test. Results: Overall, the selected studies included 6403 patients. Study design, exposure assessment, selection criteria, and outcome of interest were heterogeneous. LP studies were more common ( n = 17, 77%), whereas HP studies were more common in the latest inclusion period. Faster lithotripsy (32.9 minutes vs 63.9 minutes, p < 0.01) was observed in HP studies. However, stone volume resulted twofold higher (2604 mm 3 vs 1217 mm 3 , p = 0.048) in LP studies. Pooled stone-free rate was similar in both LP and HP studies, 81% and 82%, respectively, p > 0.05. No difference in complication rate was observed between the two groups, p = 0.12. Conclusions: HP laser lithotripsy appears to require shorter operative time, with similar stone-free and complication rates as compared with LP traditional lithotripsy. However, when taking into account stone burden, this advantage seems to be lost, or at least not to be comparable with what observed in laboratory studies. Because of the lack of high-level comparative evidence, further clinical studies are needed to elucidate the benefits of using HP laser generators during ureteroscopic stone treatment.

16 August 2023 in World Journal of Urology
Verified
Journal Article
Open access
PDF file
JKJia-Lun Kwok
Jia-Lun Kwok
Eugenio VentimigliaEugenio Ventimiglia
Eugenio Ventimiglia
VCVincent De Coninck
Vincent De Coninck
MCMariela Corrales
Mariela Corrales
ASAlba Sierra
Alba Sierra
EKEtienne Xavier Keller
Etienne Xavier Keller
Purpose: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. Methods: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). Results: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. Conclusion: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.

4 November 2023 in World Journal of Urology
Verified
Journal Article
Closed access
PDF file
FPFelipe Pauchard
Felipe Pauchard
EVEugenio Ventimiglia
Eugenio Ventimiglia
Olivier TraxerOlivier Traxer
Olivier Traxer

12 May 2025 in World Journal of Urology
Verified
Journal Article
Closed access
PDF file
MCMariela Corrales
Mariela Corrales
EKEtienne Xavier Keller
Etienne Xavier Keller
YBYazeed Barghouthy
Yazeed Barghouthy
FPFelipe Pauchard
Felipe Pauchard
VCVincent De Coninck
Vincent De Coninck
Olivier TraxerOlivier Traxer
Olivier Traxer

5 May 2024 in World Journal of Urology
Verified
Journal Article
Open access
PDF file
JKJia-Lun Kwok
Jia-Lun Kwok
VCVincent De Coninck
Vincent De Coninck
FPfrederic Panthier
frederic Panthier
HKHatem Kamkoum
Hatem Kamkoum
FPFelipe Pauchard
Felipe Pauchard
EKEtienne Xavier Keller
Etienne Xavier Keller
Purpose: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. Material and methods: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). Results: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. Conclusion: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist’s choice of instruments and settings.