Using high-strength steel (yield strength fy ≥ 460 MPa) in concrete-filled steel tubes is expected to provide a superior bearing capacity by achieving light weight and efficient construction, but the existing design limitation on diameter-to-thickness (D/t) ratios for concrete-filled high-strength steel tubular (CFHST) members inevitably obstructs its wide application. In this study, aiming at the application of circular CFHST members using Q690 steel (fy ≥ 690 MPa), a total of 15 CFHST beams were examined using a three-point loading test to investigate the failure mode, bearing capacity and plasticity evolution. Subsequently, finite element models (FEMs) were established to analyze the full-range curves, composite effect, failure mechanism and influences of key parameters including material strengths, D/t ratios, and shear-span ratios. A simplified calculation method for bearing capacity was finally proposed and verified. The results indicate that the full-range performance of tested CFHST members with out-of-code D/t ratios have ductile behavior, though they fail through the mode of steel fracture and concrete cracks in the tension zone as well as through local buckling in the compression zone; out-of-code CFHST members (e.g., D/t = 120) can perform reasonable composite behavior because of contact pressure larger than 2.5 MPa, where a thin-walled steel tube experiences an arch failure mechanism similar to core concrete at a trussed angle of 45°; the simplified bearing capacity model achieves a mean value of 0.97, and can be accepted as a primary tool to perform structural design and performance evaluation.
Strengthening reinforced concrete (RC) beams with fiber-reinforced polymer (FRP) grids and engineered cement composites (ECCs) can significantly enhance their shear capacity. However, the specific contributions of the components in reinforced RC beams remain unclear, necessitating further investigation into the flexural shear performance of RC beams. The numerical model was used to analyze the flexural shear performance of RC beams strengthened with an FRP grid and ECCs. Subsequently, the parameters affecting the flexural shear performance of beams were discussed. This included the compressive strength of concrete prism, the shear span ratio, the tensile strength of ECCs, the thickness of the ECC cover, the cross-sectional area of the FRP grid, and the number of FRP grid layers. Finally, a calculation formula was established to predict the shear capacity and verified by the outcomes from numerical models and experimental data. The findings indicated that the ECC-strengthened layer significantly contributed to increasing the shear capacity. Additionally, the FRP grids helped to reduce stress concentration in the flexural shear zone, thereby preventing premature concrete cracking. The max load increased by 8.06% when the ECC’s tensile strength increased from 4 MPa to 10 MPa. In addition, increasing the cover thickness from 8 mm to 20 mm caused the peak load to increase by 14.42%. The calculation formula introduced in this research accurately predicts the shear capacity of the oblique section of RC beams.
The thin-wall high-strength (HS) steel tube can provide strong confinement ability for core concrete due to its high yield strength, so it can achieve the purpose of confining concrete lateral deformation. In order to make full use of the mechanical properties of HS steel tube and concrete, it is necessary to study the axial compressive properties of the concrete-filled HS steel tube (CFHST) with a large diameter-to-thickness ratio (D/t). In this study, the axial compressive capacity of 15 CFHST columns with a large diameter-to-thickness ratio was tested. Then, a series of finite element (FE) models were developed to study the interaction mechanism between steel tube and concrete, the load–strain curves of typical specimens, and the effect of the key parameters. Finally, a new design proposal for CFHST compressive capacity is proposed and compared with EC4, GB50936-2014, and AIJ-97 prediction results. The results showed that the CFHST has good compressive capacity and can effectively confine the lateral deformation of core concrete; the contact pressure appears a stable stage because with a steel tube is difficult to effectively restrain the lateral deformation after steel tube yielding and partial failure of concrete; the existing design code is conservative in predicting the axial compression capacity of the CFHST with large D/t ratio.