agustoni marco

Dr. agustoni marco

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
AMagustoni marco
agustoni marco
Paolo CastelloPaolo Castello
Paolo Castello
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
In recent years, electrical substations are experiencing a rapid transition toward a fully digital measurement infrastructure in terms of data acquisition, storage, and processing. The IEC Std 61850-9-2 defines the data format, also known as sampled value (SV), to be employed by instrument transformers, merging units, and controller devices. In this scenario, it is reasonable to expect that the phasor measurement units (PMUs) will be directly connected with digital instrument transformers and will be required to process directly the SV data stream. In this article, we present the design and development of a stand-alone PMU based on digital inputs. The prototype has been characterized in terms of estimation accuracy and enriched with a novel functionality that allows for monitoring the time quality of the SV data stream. In this way, the device truly becomes an intelligent electronic device (IED) that guarantees higher interoperability and a more robust management of sporadic synchronization issues. The proposed results confirm the potential of SV-based PMUs and highlight the possibility of further enhancement for synchrophasor measurements based on digital inputs only.

27 May 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
AMagustoni marco
agustoni marco
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
This article presents an accurate and robust method to calculate the phase offset of a reference waveform, usually produced by a digital-to-analog converter (DAC) in IEC Std 61850-9-2 calibration systems. The phase offset is defined with respect to the rising edge of a reference clock signal, locked to the Global Positioning System (GPS). The proposed method relies on the synchronous acquisition of the DAC output and the clock signal. In the complex plane, where the discrete Fourier transform (DFT) is defined, the acquired signals are processed to compensate the nonideal sampling rate and windowing. The method performance and its dependence from noise and parameters are thoroughly characterized by means of extensive numerical simulations. Two validation approaches, experimental and software-based, confirm the proposed method as a valuable and robust solution for calibration purposes.

3 October 2021 in Metrology
Verified
Journal Article
Open access
PDF file
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
AMagustoni marco
agustoni marco
In this paper, we consider the calibration of measuring bridges for non-conventional instrument transformers with digital output. In this context, the main challenge is represented by the necessity of synchronization between analog and digital outputs. To this end, we propose a measurement setup that allows for monitoring and quantifying the main quantities of interest. A possible laboratory implementation is presented and the main sources of uncertainty are discussed. From a metrological point of view, technical specifications and statistical analysis are employed to draw up a rigorous uncertainty budget of the calibration setup. An experimental validation is also provided through the thorough characterization of the measurement accuracy of a commercial device in use at METAS laboratories. The proposed analysis proves how the calibration of measuring bridges for non-conventional instrument transformers requires ad hoc measurement setups and identifies possible space for improvement, particularly in terms of outputs’ synchronization and flexibility of the generation process.

5 November 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AMagustoni marco
agustoni marco
FOFrederic Overney
Frederic Overney
This paper describes two approaches for modeling impedances along the physical gap existing between the low and the high frequency range. For this purpose, the physics of a Haddad type resistor standard has been investigated taking into account the EM-field propagation as well as the effect of connectors. It turns out that above 30 MHz, the frequency dependence of the the resistance is mainly dominated by the effects of the connector system. In addition, a new capacitor standard has been designed by means of physical simulations. In both approaches, a new method to exploit the information of the impedance matrix is presented. The use of this method considerably improves the impedance model. Preliminary results show a good agreement with measured data at low and high frequencies. A first estimation of the uncertainty has been also included in the paper.

3 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
AMagustoni marco
agustoni marco
SPSophie De Préville
Sophie De Préville
FOFrédéric Overney
Frédéric Overney
This paper describes a method to model the impedance of a Haddad type resistor over a frequency interval ranging from 10 to 200 MHz, hereafter defined as LF-RF range. To this end, novel resistor standards, of 1 kΩ and 100 Ω, have been designed and manufactured with the aim of sharply identifying the nodes that define the impedance. Resistor modelling is divided into two main parts: the first one, describing the central coaxial core and the second part, describing the connectors through physical simulations and a subsequent analytical approach. The results show a remarkable good agreement between measured and modelled impedance over the whole considered frequency range. Uncertainty values allow for the traceability of the resistors up to high frequencies and for the calibration of commercial impedance analyzers within the LF-RF range.

9 March 2023 in Metrology
Verified
Journal Article
Open access
PDF file
AMagustoni marco
agustoni marco
Paolo CastelloPaolo Castello
Paolo Castello
Guglielmo FrigoGuglielmo Frigo
Guglielmo Frigo
GGGiacomo Gallus
Giacomo Gallus
Modern power systems are rapidly transitioning towards a fully digital substation paradigm. Based on the IEC 61850, a common communication protocol between the different intelligent electronic devices (IEDs) promises a significant enhancement in terms of efficiency and interoperability. In this context, synchronization represents a crucial aspect as it allows us to rigorously compare measurements taken at the same time in different locations. In this paper, we consider a measurement chain for synchrophasor estimation based on digital inputs: an instrument transformer, a stand-alone merging unit (SAMU) and a phasor measurement unit (PMU). Both the SAMU and the PMU are equipped with independent synchronization sources. In case the SAMU loses its synchronization, the final measurement result would be considered invalid until a complete restoration of the SAMU synchronization status. In view of a longer continuity of operation, this paper proposes an alternative approach to evaluate the PMU Time Quality in real-time. This approach allows for continuing crucial monitoring and control operations, such as state estimation and fault detection, even in the presence of temporary loss of synchronization. A characterization, in both simulated and experimental conditions, proves the potential and reliability of the proposed approach. In the considered test case, the come-back within a sufficient time quality is correctly detected in less than 200 s, while waiting for the full restoration of the SAMU time reference would cost several minutes.