Shouhei Koyama

Dr. Shouhei Koyama

Shinshu University
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YHYuki Haseda
Yuki Haseda
JBJulien Bonefacino
Julien Bonefacino
HTHwa-Yaw Tam
Hwa-Yaw Tam
SCShun Chino
Shun Chino
SKShouhei Koyama
Shouhei Koyama
HIHiroaki Ishizawa
Hiroaki Ishizawa
Fiber Bragg grating (FBG) sensors fabricated in silica optical fiber (Silica-FBG) have been used to measure the strain of human arteries as pulse wave signals. A variety of vital signs including blood pressure can be derived from these signals. However, silica optical fiber presents a safety risk because it is easily fractured. In this research, an FBG sensor fabricated in plastic optical fiber (POF-FBG) was employed to resolve this problem. Pulse wave signals were measured by POF-FBG and silica-FBG sensors for four subjects. After signal processing, a calibration curve was constructed by partial least squares regression, then blood pressure was calculated from the calibration curve. As a result, the POF-FBG sensor could measure the pulse wave signals with an signal to noise (SN) ratio at least eight times higher than the silica-FBG sensor. Further, the measured signals were substantially similar to those of an acceleration plethysmograph (APG). Blood pressure is measured with low error, but the POF-FBG APG correlation is distributed from 0.54 to 0.72, which is not as high as desired. Based on these results, pulse wave signals should be measured under a wide range of reference blood pressures to confirm the reliability of blood pressure measurement uses POF-FBG sensors.

22 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
KOKen Ogawa
Ken Ogawa
SKShouhei Koyama
Shouhei Koyama
YHYuki Haseda
Yuki Haseda
KFKeiichi Fujita
Keiichi Fujita
HIHiroaki Ishizawa
Hiroaki Ishizawa
KFKeisaku Fujimoto
Keisaku Fujimoto
A small-size, high-precision fiber Bragg grating interrogator was developed for continuous plethysmograph monitoring. The interrogator employs optical edge filters, which were integrated with a broad-band light source and photodetector to demodulate the Bragg wavelength shift. An amplifier circuit was designed to effectively amplify the plethysmograph signal, obtained as a small vibration of optical power on the large offset. The standard deviation of the measured Bragg wavelength was about 0.1 pm. The developed edge filter module and amplifier circuit were encased with a single-board computer and communicated with a laptop computer via Wi-Fi. As a result, the plethysmograph was clearly obtained remotely, indicating the possibility of continuous vital sign measurement.

28 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SKShouhei Koyama
Shouhei Koyama
HIHiroaki Ishizawa
Hiroaki Ishizawa
KFKeisaku Fujimoto
Keisaku Fujimoto
SCShun Chino
Shun Chino
YKYuka Kobayashi
Yuka Kobayashi
In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.

23 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SKShintaro Kurasawa
Shintaro Kurasawa
SKShouhei Koyama
Shouhei Koyama
HIHiroaki Ishizawa
Hiroaki Ishizawa
KFKeisaku Fujimoto
Keisaku Fujimoto
SCShun Chino
Shun Chino
This paper describes and verifies a non-invasive blood glucose measurement method using a fiber Bragg grating (FBG) sensor system. The FBG sensor is installed on the radial artery, and the strain (pulse wave) that is propagated from the heartbeat is measured. The measured pulse wave signal was used as a collection of feature vectors for multivariate analysis aiming to determine the blood glucose level. The time axis of the pulse wave signal was normalized by two signal processing methods: the shortest-time-cut process and 1-s-normalization process. The measurement accuracy of the calculated blood glucose level was compared with the accuracy of these signal processing methods. It was impossible to calculate a blood glucose level exceeding 200 mg/dL in the calibration curve that was constructed by the shortest-time-cut process. In the 1-s-normalization process, the measurement accuracy of the blood glucose level was improved, and a blood glucose level exceeding 200 mg/dL could be calculated. By verifying the loading vector of each calibration curve to calculate the blood glucose level with a high measurement accuracy, we found the gradient of the peak of the pulse wave at the acceleration plethysmogram greatly affected.

12 May 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SKShouhei Koyama
Shouhei Koyama
YHYuki Haseda
Yuki Haseda
HIHiroaki Ishizawa
Hiroaki Ishizawa
FOFuta Okazaki
Futa Okazaki
JBJulien Bonefacino
Julien Bonefacino
HTHwa-Yaw Tam
Hwa-Yaw Tam
There is a need to develop sensors that can measure vital signs such as pulse rate and blood pressure easily; such vital signs can be calculated by measuring arterial strain. To this end, a new method that uses a plastic fiber Bragg grating (FBG) sensor to measure pulsation strain at human fingertips is proposed herein. Plastic fiber has a smaller Young’s modulus than that of the glass fiber. Under the same applied pressure, the plastic FBG sensor deforms more than the silica glass FBG sensor, and the Bragg wavelength shift length becomes longer, which results in higher detection sensitivity. The pulsation strain of the fingertip was measured by the proposed method based on this characteristic. The most sensitive signal detection point in the fingertip was the measurement point 10 or 15 mm from the distal interphalangeal joint in the fingertip direction. Strain signals with periodic peaks were measured from five participants. From the strain signal measured with the cuff attached to the arm, the peak disappeared when the cuff moved, and it reappeared when the cuff was opened. Therefore, the measured signal waveform changes based on the blood flow condition. The pulse rate calculated from the peak interval of the measured signal showed high correlation with the reference pulse rate, and the measurement accuracy was ±5.5 bpm. It may be possible to calculate the blood pressure and pulse rate from the measurement signal of the pulsation strain of the fingertip obtained using the plastic FBG sensor.

1 January 2017 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
SKShouhei Koyama
Shouhei Koyama
HIHiroaki Ishizawa
Hiroaki Ishizawa
ASAkio Sakaguchi
Akio Sakaguchi
SHSatoshi Hosoya
Satoshi Hosoya
TKTakashi Kawamura
Takashi Kawamura
We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG) sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.