22 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
KOKen Ogawa
Ken Ogawa
SKShouhei Koyama
Shouhei Koyama
YHYuki Haseda
Yuki Haseda
KFKeiichi Fujita
Keiichi Fujita
HIHiroaki Ishizawa
Hiroaki Ishizawa
KFKeisaku Fujimoto
Keisaku Fujimoto
A small-size, high-precision fiber Bragg grating interrogator was developed for continuous plethysmograph monitoring. The interrogator employs optical edge filters, which were integrated with a broad-band light source and photodetector to demodulate the Bragg wavelength shift. An amplifier circuit was designed to effectively amplify the plethysmograph signal, obtained as a small vibration of optical power on the large offset. The standard deviation of the measured Bragg wavelength was about 0.1 pm. The developed edge filter module and amplifier circuit were encased with a single-board computer and communicated with a laptop computer via Wi-Fi. As a result, the plethysmograph was clearly obtained remotely, indicating the possibility of continuous vital sign measurement.

1 June 2018
Verified
Conference Paper
Closed access
KOKen Ogawa
Ken Ogawa
SKShouhei Koyama
Shouhei Koyama
HIHiroaki Ishizawa
Hiroaki Ishizawa
SFSeiya Fujiwara
Seiya Fujiwara
KFKeisaku Fujimoto
Keisaku Fujimoto
Heart sound, pulse wave and respiration are simultaneously measured with single fiber Bragg grating(FBG) sensor. The FBG sensor is inscribed in optical fiber so that it is quite thinner than conventional electrical sensor, even enough to be weaved in clothes. In this study, single FBG sensor is taped near the Tricuspid area and on the carotid artery with the surgical tape. Measured data is denoised through digital Butterworth filter with low pass filter (0.2 Hz), medium frequency band pass filter (0.5 Hz - 5.0 Hz) and higher frequency bandpass filter (35.0 Hz - 55.0 Hz) to extract the information of respiration, pulse wave and heart sound, respectively. The lower frequency signal follows the reference respiration sensor. The medium and higher frequency signal contains the features of typical pulse wave and heart sound waveform. The pulse wave measured on precordium contains the feature of apex cardiogram. The result also indicate that the timing of the heart sound is slightly delayed on the carotid artery. These results indicate the possibility of wearable, continuous vital sigh measurement system.

1 October 2019 in AIP Advances
Verified
Journal Article
Open access
PDF file
KOKen Ogawa
Ken Ogawa
KFKeiichi Fujita
Keiichi Fujita
TYTsutomu Yamate
Tsutomu Yamate
The simultaneous measurement of temperature and pressure using the reflected light of two high birefringent fibers is studied. These two fibers are spliced and twisted 45 degrees. The resulting spectrum contains the interference caused by the birefringence of each fiber, and the differential and sum of the frequency. The obtained spectrum is processed with a band-pass filter to get the spectrum of each fiber. The pressure and the temperature are demodulated using the peak-tracking method. As a result, the pressure and the temperature sensitivity of these individual fibers are obtained as 3.2nm/MPa and -1.6nm/K for the PANDA fiber, and 3.2nm/MPa and negligible temperature sensitivity for the PM-PCF. This method produces an easily encapsulated, highly sensitive temperature and pressure sensor without any additional type of sensor.