Chen Wang

Dr. Chen Wang


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
YWYuan Wang
Yuan Wang
Chun ZhaoChun Zhao
Chun Zhao
CWChen Wang
Chen Wang
DCDelphine Cerica
Delphine Cerica
MBMathieu Baijot
Mathieu Baijot
MKMichael Kraft
Michael Kraft

15 April 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
QLQianbo Lu
Qianbo Lu
CWChen Wang
Chen Wang
Jian BaiJian Bai
Jian Bai
KWKaiwei Wang
Kaiwei Wang
SLShuqi Lou
Shuqi Lou
YYYongying Yang
Yongying Yang
Cross-axis sensitivity of single-axis optomechanical accelerometers, mainly caused by the asymmetric structural design, is an essential issue primarily for high performance applications, which has not been systematically researched. This paper investigates the generating mechanism and detrimental effects of the cross-axis sensitivity of a high resoluion single-axis optomechanical accelerometer, which is composed of a grating-based cavity and an acceleration sensing chip consisting of four crab-shaped cantilevers and a proof mass. The modified design has been proposed and a prototype setup has been built based on the model of cross-axis sensitivity in optomechanical accelerometers. The characterization of the cross-axis sensitivity of a specific optomechanical accelerometer is quantitatively discussed for both mechanical and optical components by numerical simulation and theoretical analysis in this work. The analysis indicates that the cross-axis sensitivity decreases the contrast ratio of the interference signal and the acceleration sensitivity, as well as giving rise to an additional optical path difference, which would impact the accuracy of the accelerometer. The improved mechanical design is achieved by double side etching on a specific double-substrate-layer silicon-on-insulator (SOI) wafer to move the center of the proof mass to the support plane. The experimental results demonstrate that the modified design with highly symmetrical structure can suppress the cross-axis sensitivity significantly without compromising the sensitivity and resolution. The cross-axis sensitivity defined by the contrast ratio of the output signal drops to 2.19% /0.1g from 28.28%/0.1g under the premise that the acceleration sensitivity of this single-axis optomechanical accelerometer remains 1162.45V/g and the resolution remains 1.325μg.

19 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Linlin WangLinlin Wang
Linlin Wang
CWChen Wang
Chen Wang
Yuan WangYuan Wang
Yuan Wang
AQAojie Quan
Aojie Quan
MKMasoumeh Keshavarz
Masoumeh Keshavarz
Michael KraftMichael Kraft
Michael Kraft
With the introduction of the working principle of coupled resonators, the coupled bulk acoustic wave (BAW) Micro-Electro-Mechanical System (MEMS) resonators have been attracting much attention. In this paper, coupled BAW MEMS resonators are discussed, including the coupling theory, the actuation and sensing theory, the transduction mechanism, and the applications. BAW MEMS resonators normally exhibit two types of vibration modes: lateral (in-plane) modes and flexural (out-of-plane) modes. Compared to flexural modes, lateral modes exhibit a higher stiffness with a higher operating frequency, resulting in a lower internal loss. Also, the lateral mode has a higher Q factor, as the fluid damping imposes less influence on the in-plane motion. The coupled BAW MEMS resonators in these two vibration modes are investigated in this work and their applications for sensing, timing, and frequency reference are also presented.

29 April 2015 in Applied Optics
Verified
Journal Article
Closed access
PDF file
QLQianbo Lu
Qianbo Lu
CWChen Wang
Chen Wang
Jian BaiJian Bai
Jian Bai
KWKaiwei Wang
Kaiwei Wang
WLWenxiu Lian
Wenxiu Lian
GYGuoguang Yang
Guoguang Yang
A subnanometer resolution displacement sensor based on a grating interferometric cavity with intensity compensation and phase modulation is proposed and experimentally demonstrated in this paper. The grating interferometric cavity is composed of a frequency-stabilized laser source, a diffraction grating, and a mirror. To realize a subnanometer resolution, the intensity compensation and phase modulation technique are introduced, which are achieved by an intensity compensation light path, three closed placed photodetectors, a processing circuit and a piezoelectric ceramic transducer, and a lock-in amplifier. The intensity compensation technique can improve the stability of the output intensity signal greatly while the phase modulation technique can increase the signal-to-noise ratio dramatically. The detected signal is intensity modulated and processed by a particular arithmetic circuit. Experimental results indicate that the sensitivity of this displacement sensor is 44.75 mV/nm and the highest resolution can reach 0.017 nm, which is 27 times better than the one without intensity compensation and phase modulation. As a high-performance sensor with immunity to electromagnetic interference, this displacement sensor has potential to be used in nanoscience and technology.

13 November 2024 in Transportation Geotechnics
Verified
Journal Article
Closed access
CWChen Wang
Chen Wang
QWQiuyue Wu
Qiuyue Wu
JLJiaxin Liang
Jiaxin Liang
FLFayun Liang
Fayun Liang
XYXiong Yu
Xiong Yu

16 January 2025 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
SJSanjog Vilas Joshi
Sanjog Vilas Joshi
SSSina Sadeghpour
Sina Sadeghpour
NKNadezda Kuznetsova
Nadezda Kuznetsova
CWChen Wang
Chen Wang
MKMichael Kraft
Michael Kraft
The use of bulk piezoelectric transducer arrays in medical imaging is a well-established technology that operates based on thickness mode piezoelectric vibration. Meanwhile, advancements in fabrication techniques have led to the emergence of micromachined alternatives, namely, piezoelectric micromachined ultrasound transducer (PMUT) and capacitive micromachined ultrasound transducer (CMUT). These devices operate in flexural mode using piezoelectric thin films and electrostatic forces, respectively. In addition, the development of flexible ultrasound transducers based on these principles has opened up new possibilities for biomedical applications, including biomedical imaging, sensing, and stimulation. This review provides a detailed discussion of the need for flexible micromachined ultrasound transducers (MUTs) and potential applications, their specifications, materials, fabrication, and electronics integration. Specifically, the review covers fabrication approaches and compares the performance specifications of flexible PMUTs and CMUTs, including resonance frequency, sensitivity, flexibility, and other relevant factors. Finally, the review concludes with an outlook on the challenges and opportunities associated with the realization of efficient MUTs with high performance and flexibility.