Influenza virus infection can result in changes in the cellular ion levels at 2–3 hours post-infection. More H+ is produced by glycolysis, and the viral M2 proton channel also plays a role in the capture and release of H+ during both viral entry and egress. Then the cells might regulate the intracellular pH by increasing the export of H+ from the intracellular compartment. Increased H+ export could lead indirectly to increased extracellular acidity. To detect changes in extracellular pH of both virus-infected and uninfected cells, pH sensors were synthesized using polystyrene beads (1μm) containing Rhodamine B and Fluorescein isothiocyanate (FITC). The fluorescence intensity of FITC can respond to both pH and temperature. So Rhodamine B was also introduced in the sensor for temperature compensation. Then the pH can be measured after temperature compensation. The sensor was adhered to cell membrane for extracellular pH measurement. The results showed that the multiplication of influenza virus in host cell decreased extracellular pH of the host cell by 0.5–0.6 in 4 hours after the virus bound to the cell membrane, compared to that in uninfected cells. Immunostaining revealed the presence of viral PB1 subunits in the nucleus of virus-bound cells that exhibited extracellular pH changes, but no PB1 subunits are detected in virus-unbound cells where the extracellular pH remained constant.
In this research, atomic force microscopy (AFM) with a flat tip cantilever is utilized to measure Young's modulus of a whole yeast cell (Saccharomyces cerevisiae BY4741). The results acquired from AFM are similar to those obtained using a microfluidic chip compression system. The mechanical properties of single yeast cells are important parameters which can be examined using AFM. Conventional studies apply AFM with a sharp cantilever tip to indent the cell and measure the force-indentation curve, from which Young's modulus can be calculated. However, sharp tips introduce problems because the shape variation can lead to a different result and cannot represent the stiffness of the whole cell. It can lead to a lack of broader meaning when evaluating Young's modulus of yeast cells. In this report, we confirm the differences in results obtained when measuring the compression of a poly(dimethylsiloxane) bead using a commercial sharp tip versus a unique flat tip. The flat tip effectively avoids tip-derived errors, so we use this method to compress whole yeast cells and generate a force–deformation curve. We believe our proposed method is effective for evaluating Young's modulus of whole yeast cells.
This work describes a hydrogel fluorescence microsensor for prolonged stable temperature measurements. Temperature measurement using microsensors has the potential to provide information about cells, tissues, and the culture environment, with optical measurement using a fluorescent dye being a promising microsensing approach. However, it is challenging to achieve stable measurements over prolonged periods with conventional measurement methods based on the fluorescence intensity of fluorescent dye because the excited fluorescent dye molecules are bleached by the exposure to light. The decrease in fluorescence intensity induced by photobleaching causes measurement errors. In this work, a photobleaching compensation method based on the diffusion of fluorescent dye inside a hydrogel microsensor is proposed. The factors that influence compensation in the hydrogel microsensor system are the interval time between measurements, material, concentration of photo initiator, and the composition of the fluorescence microsensor. These factors were evaluated by comparing a polystyrene fluorescence microsensor and a hydrogel fluorescence microsensor, both with diameters of 20 µm. The hydrogel fluorescence microsensor made from 9% poly (ethylene glycol) diacrylate (PEGDA) 575 and 2% photo initiator showed excellent fluorescence intensity stability after exposure (standard deviation of difference from initial fluorescence after 100 measurement repetitions: within 1%). The effect of microsensor size on the stability of the fluorescence intensity was also evaluated. The hydrogel fluorescence microsensors, with sizes greater than the measurement area determined by the axial resolution of the confocal microscope, showed a small decrease in fluorescence intensity, within 3%, after 900 measurement repetitions. The temperature of deionized water in a microchamber was measured for 5400 s using both a thermopile and the hydrogel fluorescence microsensor. The results showed that the maximum error and standard deviation of error between these two sensors were 0.5 °C and 0.3 °C, respectively, confirming the effectiveness of the proposed method.
The continual development of surgical technology has led to a demand for surgical simulators for evaluating and improving the surgical technique of surgeons. To meet these needs, simulators must incorporate a sensing function into the organ model for evaluating the surgical techniques. However, it is difficult to incorporate a temperature sensor into the conventional cardiac training model. In this study, we propose a heart model for surgical training of cardiac catheter ablation made from hydrogel, which has temperature memory properties. The heart model consists of a photo-crosslinkable hydrogel mixed with an irreversible temperature indicator that exhibits a color change from magenta to colorless at 55 °C. The Young’s modulus, electrical resistivity, thermal conductivity, and specific heat capacity of the hydrogel material were evaluated and compared with those of human heart. Furthermore, temperature calibration based on the color of the hydrogel material confirmed that the temperature measurement accuracy of the material is ±0.18 °C (at 56 °C). A heart model for catheter ablation was fabricated using the hydrogel material and a molding method, and the color change due to temperature change was evaluated.