Hashim Hairulazwan

Dr. Hashim Hairulazwan

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HHHashim Hairulazwan
Hashim Hairulazwan
Hisataka MaruaymaHisataka Maruayma
Hisataka Maruayma
YAYusuke Akita
Yusuke Akita
AFArai Fumihito
Arai Fumihito
This work describes a hydrogel fluorescence microsensor for prolonged stable temperature measurements. Temperature measurement using microsensors has the potential to provide information about cells, tissues, and the culture environment, with optical measurement using a fluorescent dye being a promising microsensing approach. However, it is challenging to achieve stable measurements over prolonged periods with conventional measurement methods based on the fluorescence intensity of fluorescent dye because the excited fluorescent dye molecules are bleached by the exposure to light. The decrease in fluorescence intensity induced by photobleaching causes measurement errors. In this work, a photobleaching compensation method based on the diffusion of fluorescent dye inside a hydrogel microsensor is proposed. The factors that influence compensation in the hydrogel microsensor system are the interval time between measurements, material, concentration of photo initiator, and the composition of the fluorescence microsensor. These factors were evaluated by comparing a polystyrene fluorescence microsensor and a hydrogel fluorescence microsensor, both with diameters of 20 µm. The hydrogel fluorescence microsensor made from 9% poly (ethylene glycol) diacrylate (PEGDA) 575 and 2% photo initiator showed excellent fluorescence intensity stability after exposure (standard deviation of difference from initial fluorescence after 100 measurement repetitions: within 1%). The effect of microsensor size on the stability of the fluorescence intensity was also evaluated. The hydrogel fluorescence microsensors, with sizes greater than the measurement area determined by the axial resolution of the confocal microscope, showed a small decrease in fluorescence intensity, within 3%, after 900 measurement repetitions. The temperature of deionized water in a microchamber was measured for 5400 s using both a thermopile and the hydrogel fluorescence microsensor. The results showed that the maximum error and standard deviation of error between these two sensors were 0.5 °C and 0.3 °C, respectively, confirming the effectiveness of the proposed method.

1 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
HHHashim Hairulazwan
Hashim Hairulazwan
Hisataka MaruaymaHisataka Maruayma
Hisataka Maruayma
TMTaisuke Masuda
Taisuke Masuda
AFArai Fumihito
Arai Fumihito
Manipulation and injection of single nanosensors with high cell viability is an emerging field in cell analysis. We propose a new method using fluorescence nanosensors with a glass nanoprobe and optical control of the zeta potential. The nanosensor is fabricated by encapsulating a fluorescence polystyrene nanobead into a lipid layer with 1,3,3-trimethylindolino-6′-nitrobenzopyrylospiran (SP), which is a photochromic material. The nanobead contains iron oxide nanoparticles and a temperature-sensitive fluorescent dye, Rhodamine B. The zeta potential of the nanosensor switches between negative and positive by photo-isomerization of SP with ultraviolet irradiation. The positively-charged nanosensor easily adheres to a negatively-charged glass nanoprobe, is transported to a target cell, and then adheres to the negatively-charged cell membrane. The nanosensor is then injected into the cytoplasm by heating with a near-infrared (NIR) laser. As a demonstration, a single 750 nm nanosensor was picked-up using a glass nanoprobe with optical control of the zeta potential. Then, the nanosensor was transported and immobilized onto a target cell membrane. Finally, it was injected into the cytoplasm using a NIR laser. The success rates of pick-up and cell immobilization of the nanosensor were 75% and 64%, respectively. Cell injection and cell survival rates were 80% and 100%, respectively.

1 November 2017
Verified
Conference Paper
Closed access
KKKharis Khasburrahman
Kharis Khasburrahman
AWAdi Wibowo
Adi Wibowo
IWIndra Waspada
Indra Waspada
HHHashim Hairulazwan
Hashim Hairulazwan
WJWisnu Jatmiko
Wisnu Jatmiko
MicroRNA(miRNA) expression that have great potential serving as cancer biomarkers and therapeutic targets generally has a very large number and has brought great challenge for identification of the most feature sets. In this paper, combinatorial miRNA biomarkers from the diagnostic set and feature selection are comprised for breast cancer classification using Naive Bayes and backpropagation. The diagnostic set of miRNA are provided from recent bioinformatics and medical research results. Moreover, greedy stepwise using Naive Bayes and Multi Layer Perceptron method are utilized for feature selection in order to reduce number of miRNA set from 1881 features. MiRNA expression in Cancer and normal breast cells are examined to study this comparison. The classification performance of input sets were implemented and studied thoroughly in terms of Sensitivity, Specificity, Classification Accuracy and ROC value. Based on experimental results, this study obtained recommended features for cancer classification with less number than diagnostic sets and in this study, the essential features for cancer analysis are discovered as new essential biomarkers.

1 March 2009
Verified
Conference Paper
Closed access
HHHashim Hairulazwan
Hashim Hairulazwan
HAHerdawatie AbdulKadir
Herdawatie AbdulKadir
As the number of field devices in manufacturing systems grows and the functions of the system need to be more intelligent, these devices need to exchange the rapidly increasing amount of data among them. Implementing Ethernet even at the lowest level is suitable for a better interface and offer advantages of direct access of information and equipment diagnostic. This paper proposes the integration between the industrial communications network based on the Ethernet protocol and Computer Integrated Manufacturing (CIM) system. The Ethernet module is installed onto supervisory OMRON PLC to integrate several stations in the CIM-70A system to overcome real-time communication in terms of retrieving data from other stations. The workability of this communication technique is analyzed and compared with the conventional serial communication which is widely used in automation networking systems. It is found that, the Ethernet protocol approach through the communication and integration of CIM system can be accessed easily and available to be upgraded at the management and enterprise levels of industrial automation system.

1 October 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
ASAmirul Syafiq Sadun
Amirul Syafiq Sadun
JJJamaludin Jalani
Jamaludin Jalani
SNSiti Hana Nasir
Siti Hana Nasir
MRMohd Nazrul Roslan
Mohd Nazrul Roslan
HHHashim Hairulazwan
Hashim Hairulazwan
SASyazwani Mohd Anuar
Syazwani Mohd Anuar
This research present the development of a two-fingered underactuated robot gripper by using 3D printed machine with a material of Polylactic acid or PLA. The gripper design consist of two individual servo motors that drives the finger movement to perform a certain amount of grasping force. The new design of the finger using Solidworks was inspired by several existing robot gripper however with a low cost approach to obtain a good finger tracking and angular control. The fully fabricated and assembled gripper was then tested to determine the operation results during basic grasping and ungrasping by connected to Arduino Mega and MATLAB software. The angular data during the operation shows that the gripper successfully perform a stable operations despite some minor disturbance due to the mechanical defect on the servo plate. Further analysis will be conducted in the future in order to identify the full capability of the gripper in real world application such as force control operations.

28 February 2025 in Journal of Advanced Research in Applied Mechanics
Verified
Journal Article
Open access
PDF file
HHHashim Hairulazwan
Hashim Hairulazwan
ASAmirul Syafiq Sadun
Amirul Syafiq Sadun
NJNor Anija Jalaludin
Nor Anija Jalaludin
SCSaranjuu Chulakit
Saranjuu Chulakit
SASUZIANA AHMAD
SUZIANA AHMAD
ZWZhiWen Wang
ZhiWen Wang
Manufacturing industries often face challenges in optimizing machine performance due to the limitations of traditional downtime monitoring methods, which are time-consuming and prone to errors. The lack of real-time capabilities in these methods leads to delayed identification and resolution of machine issues, ultimately affecting productivity. This research aims to develop a real-time machine downtime monitoring system that leverages sensors, vision systems, and LabVIEW software to enhance the detection and analysis of production line performance. The system uses image processing techniques for product quality assessment, enabling the detection of good and defective products, and integrates vibration sensors to monitor equipment conditions. The Arduino microcontroller is employed to manage sensor data and motor functions, while LabVIEW software facilitates real-time visualization and data analysis. The system demonstrated high accuracy in detecting both product defects and equipment vibrations, although sensitivity to lighting conditions and low-powered motors presents areas for future improvement. The integration of this system into production lines has the potential to significantly reduce downtime and improve operational efficiency, contributing to more automated and reliable industrial processes.