The present study explored the degradation law and service life prediction of tunnel lining concrete with different mineral admixtures under coupled actions of sulfate attack (SA) and drying–wetting (DW) cycles. The deterioration resistance coefficient (DRC) of compressive strength and influence coefficients of sulfate concentration, mineral admixture content, water/binder (w/b) ratio, and curing regime on DRC were studied. After that, a new service life prediction model based on damage mechanics was developed and analyzed. Results show that, by increasing the DW cycles, the DRC first increases and then decreases. DRCs of Ordinary Portland cement (OPC), fly ash (FA), and ground granulated blast-furnace slag (GGBS) concrete linearly decrease with the increase of sulfate concentration, while the silica fume (SF) concrete displays a two-stage process; by increasing the admixture content, the DRCs of FA and GGBS concrete exhibit two distinct stages, while the SF concrete depicts a three-stage process; increasing the w/b ratio linearly decreases the DRC; the DRC of curing regime was sequenced as standard curing (SC) > fog curing (FC) > water curing (WC) > same condition curing (SCC). Based on the experimental results, the service life prediction model is applied and validated. The validation results show that the proposed model can accurately predict the lifetime of concrete with different mix proportions. Furthermore, it is found that the mineral admixture can effectively improve the lifetime of concrete, and the composite mineral admixture is more effective than a single mineral admixture in improving the lifetime of concrete.
Given the shortcomings of the tunnel overbreak and underbreak control and primary support sectional area detection such as the single means, large workload, low efficiency, and poor accuracy, the use of three‐dimensional laser technology can solve the above problems. Based on the Badaling Tunnel Great Wall underground station of the Beijing‐Zhangjiakou Railway, the 3D laser scanning technology is used to analyze the distribution of the tunnel overbreak and underbreak and the sectional area of the primary support, compared with the total station measurement results. The results showed that the layout of the scanning measurement station should consider the requirements of scanning accuracy, control the station length and scanning incidence angle, and minimize the scanning station length to reduce the scanning error. The majority of the tunnel section was in overbreak, with the overbreak area ranging from 6.22 m2 to 13.17 m2and the overbreak rate ranging from 0.283 to 0.598, and the area of underbreak was relatively small; no overexceeded headroom was found in the primary support, and the tunnel vault was not overbreak. The primary support clearance value of the vault is 0∼15 mm, the clearance value of the sidewall is 35 mm∼40 mm, and the sidewall needs to be secondary shotcrete. The difference value between the 3D laser scanning measurement data and the total station measurement data is within 3 mm, which is within the error range, indicating the validity and reliability of the 3D laser measurement result.
This research paper systematically investigates the combined influence of fly ash, cementitious capillary crystalline waterproofing (CCCW) materials, and polypropylene fibers on the mechanical properties and impermeability of concrete through comprehensive orthogonal tests. Microscopic morphological changes in the concrete induced by different composite materials are examined via scanning electron microscopy (SEM) and X-ray diffraction (XRD) testing. The objective is to facilitate a beneficial synergetic interaction among these materials to develop highly permeable, crack-resistant concrete. Key findings of this study are: (1) The study unveils the impact of the concentration of three additive materials on the concrete’s compressive strength, tensile strength, and penetration height, thereby outlining their significant influence on the mechanical properties and impermeability of the concrete; (2) An integrated scoring method determined the optimal composite dosage of three materials: 15% fly ash, 2% CCCW, and polypropylene fibers at 1.5 kg/m3. This combination increased the concrete’s compressive strength by 12.5%, tensile strength by 48.4%, and decreased the average permeability height by 63.6%; (3) The collective introduction of these three materials notably augments the hydration reaction of the cement, resulting in denser concrete microstructure, enhanced bonding between fibers and matrix, and improved concrete strength and durability.
In recent years, steel fiber-reinforced concrete (SFRC) single-layer linings have been used in tunnel engineering. Compared to plain concrete single-layer linings, SFRC single-layer linings demonstrate enhanced bearing capacity, durability, and sustainability. Existing studies primarily focused on the mechanical properties of SFRC; however, limited investigations have been conducted on the cracking pattern of SFRC linings. This study uses laboratory tests to examine the influence of steel fiber content and aspect ratio on the mechanical properties of concrete, such as compressive strength and elastic modulus. After the recommended content and aspect ratio of steel fiber are proposed through tests, the cracking pattern and safety performance of plain concrete and SFRC linings under surrounding rock pressure are studied using a similar model test. The test results indicate that the recommended steel fiber volume fraction and aspect ratio for CF35 SFRC are 0.58% and 70, respectively. Due to the effect of loose load, cracks initially develop on the inside of arch crowns in both plain concrete and SFRC single-layer linings. Subsequently, new cracks appear on the inside of the lining floor and the outside of the two wall feet. Numerous narrow cracks with rugged and winding expansion paths can be found on SFRC single-layer linings. Conversely, plain concrete single-layer linings exhibit fewer cracks with larger widths along a straighter path. The initial cracking load of a single-layer lining made of plain concrete is 0.027 MPa, whereas for a single-layer lining made of SFRC, it is 0.04 MPa. This indicates that SFRC can effectively enhance the initial cracking load of lining structures. In the event of damage to the lining, the most critical area for the plain concrete single-layer lining is at the two wall feet, where the minimum safety factor is 1.66. However, for the SFRC lining in the same location, the safety factor is 2.7, resulting in a 62.7% increase in safety.
With an increase in the service time of high-speed railway tunnels, various defects caused by construction-quality defects in the secondary lining begin to appear. How to evaluate the safety of such tunnels and take countermeasures is very important for the safe operation of tunnels. Based on the load-structure method and a numerical simulation, this paper studied the short-term and long-term safety of the missing section of anti-crack reinforcement mesh in the plain concrete lining of a high-speed railway mountain tunnel. The short-term safety evaluation considered the influence of negative pressure caused by aerodynamic effects. The long-term safety evaluation considered the combined influence of the surrounding rock and concrete deterioration and the negative pressure and concrete fatigue damage caused by aerodynamic effects. The results showed that under the negative pressure generated by aerodynamic effects, the minimum tensile safety factor of the lining in the defective section increased by 3.8%, while the minimum compressive safety factor of the lining decreased by 7.9%. The negative pressure generated by the aerodynamic effects had little impact on the short-term safety of the lining in the defective section. During the long-term safety evaluation, the overall safety of the defective section decreased significantly, and the minimum tensile and minimum compressive safety factors of the lining decreased by 59.4% and 66.8%, respectively. The calculation results for the initial design do not meet the long-term design requirements and cannot guarantee the long-term safe operation of the tunnel. Finally, two new strengthening methods of galvanized steel mesh-short bolts and galvanized corrugated steel plate-short bolts were proposed to strengthen the defective section of the concrete lining, so as to improve the ultimate bearing capacity and toughness of the plain concrete lining structure.