Lingfeng Li

Dr. Lingfeng Li


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2022 in Molecules
Verified
Journal Article
Open access
PDF file
LLLingfeng Li
Lingfeng Li
TZTianyi Zhang
Tianyi Zhang
DWDeting Wang
Deting Wang
YZYunjing Zhang
Yunjing Zhang
XHXingli He
Xingli He
PLPeng Li
Peng Li
As narcotic control has become worse in the past decade and the death toll of drug abuse hits a record high, there is an increasing demand for on-site rapid detection of illegal drugs. This work developed a portable digital linear ion trap mass spectrometer based on separate-region corona discharge ionization source to meet this need. A separate design of discharge and reaction regions was adopted with filter air as both carrier gas for the analyte and protection of the corona discharge needle. The linear ion trap was driven by a digital waveform with a low voltage (±100 V) to cover a mass range of 50–500 Da with a unit resolution at a scan rate of 10,000 Da/s. Eighteen representative drugs were analyzed, demonstrating excellent qualitative analysis capability. Tandem mass spectrometry (MS/MS) was also performed by ion isolation and collision-induced dissociation (CID) with air as a buffer gas. With cocaine as an example, over two orders of magnitude dynamic range and 10 pg of detection limit were achieved. A single analysis time of less than 10 s was obtained by comparing the information of characteristic ions and product ions with the built-in database. Analysis of a real-world sample further validated the feasibility of the instrument, with the results benchmarked by GC-MS. The developed system has powerful analytical capability without using consumables including solvent and inert gas, meeting the requirements of on-site rapid detection applications.

17 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
LLLingfeng Li
Lingfeng Li
TZTianyi Zhang
Tianyi Zhang
WGWei Ge
Wei Ge
XHXingli He
Xingli He
YZYunjing Zhang
Yunjing Zhang
PLPeng Li
Peng Li
A novel sample introduction and ionization method for trace explosives detection is proposed and investigated herein, taking into consideration real-world application requirements. A thermal desorption sampling method and dielectric barrier discharge ionization (DBDI) source, with air as the discharge gas, were developed. The counter flow method was adopted firstly into the DBDI source to remove the interference of ozone and other reactive nitrogen oxides. A separated reaction region with an ion guiding electric field was developed for ionization of the sample molecules. Coupled with a homemade miniature digital linear ion trap mass spectrometer, this compact and robust design, with further optimization, has the advantages of soft ionization, a low detection limit, is free of reagent and consumable gas, and is an easy sample introduction. A range of common nitro-based explosives including TNT, 2,4-DNT, NG, RDX, PETN, and HMX has been studied. A linear response in the range of two orders of magnitude with a limit of detection (LOD) of 0.01 ng for TNT has been demonstrated. Application to the detection of real explosives and simulated mixed samples has also been explored. The work paves the path to developing next generation mass spectrometry (MS) based explosive trace detectors (ETDs).

27 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LLLingfeng Li
Lingfeng Li
HGHao Gu
Hao Gu
YLYanzhen Lv
Yanzhen Lv
YZYunjing Zhang
Yunjing Zhang
XHXingli He
Xingli He
PLPeng Li
Peng Li
Drift-time ion mobility spectrometer (DT-IMS) is a promising technology for gas detection and analysis in the form of miniaturized instrument. Analytes may exist in the form of positively or negatively charged ions according to their chemical composition and ionization condition, and therefore require both polarity of electric field for the detection. In this work the polarity switching of a drift-time ion mobility spectrometer based on a direct current (DC) corona discharge ionization source was investigated, with novel solutions for both the control of ion shutter and the stabilization of aperture grid. The drift field is established by employing a switchable high voltage power supply and a serial of voltage regulator diode, with optocouplers to drive the ion shutter when the polarity is switched. The potential of aperture grid is stabilized during the polarity switching by the use of four diodes to avoid unnecessary charging cycle of the aperture grid capacitor. Based on the proposed techniques, the developed DT-IMS with 50 mm drift path is able to switch its polarity in 10 ms and acquire mobility spectrum after 10 ms of stabilization. Coupled with a thermal desorption sampler, limit of detection (LoD) of 0.1 ng was achieved for ketamine and TNT. Extra benefits include single calibration substance for both polarities and largely simplified pneumatic design, together with the reduction of second drift tube and its accessories. This work paved the way towards further miniaturization of DT-IMS without compromise of performance.

25 January 2024 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
CDChangxuan Duan
Changxuan Duan
JZJiashu Zhang
Jiashu Zhang
TXTianxin Xian
Tianxin Xian
LLLingfeng Li
Lingfeng Li
YZYunjing Zhang
Yunjing Zhang
PLPeng Li
Peng Li

23 December 2024 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
JRJie Ren
Jie Ren
PCPingping Chen
Pingping Chen
YZYunjing Zhang
Yunjing Zhang
XHXingli He
Xingli He
LLLingfeng Li
Lingfeng Li
PLPeng Li
Peng Li

6 August 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
TWTianyun Wu
Tianyun Wu
YWYan Wang
Yan Wang
WLWenhui Li
Wenhui Li
LLLingfeng Li
Lingfeng Li
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang
XHXingli He
Xingli He