In this work, a reflective polarization conversion metasurface (PCM) with symmetrical L-shaped patches is proposed which enables to switch between different polarization modes by PIN diodes, i.e., linear-to-linear (LTL) cross-polarization and linear-to-circular (LTC) polarization. Because of multimodes activated in the structure, the PCM shows an ultrawide bandwidth both for LTL and LTC polarization conversion. A microstrip line-based DC biasing network composed of radial stubs is introduced to isolate RF currents, which can resolve problems raised by RF lumped choke inductors in the ultrawide bandwidth. A prototype with 15 × 15 units is fabricated. The simulated and measured results show that when the PIN diodes are forward biased, the PCM achieves LTC polarization conversion in the range of 5.96–15.34 GHz (relative bandwidth of 88.4%) with the axial ratio (AR) less than 3 dB; when the PIN diodes are reverse biased, the PCM achieves LTL polarization conversion in the range of 6.05–14.76 GHz (relative bandwidth of 83.75%) with the polarization conversion ratio (PCR) higher than 90%. The proposed PCM is expected to be potentially applied to a broad scanning range array, intelligent reflecting surfaces (IRS), and remote sensing.
9 November 2018 in IEEE Transactions on Antennas and Propagation
This paper presents an effective design method of chipless RIFD tags. With n-bit first- and second-order chipless tags’ equivalent circuits proposed based on filter theory, the relation between bits and frequency bands of tags is characterized by formulas. Combining with microstrip-line theory, the firstorder chipless tag with single quarter-wave open-circuited (O.C.) shunt stub units, and second-order chipless tag with parallel pairs of quarter-wave O.C. shunt stubs are designed, respectively. The pros and cons for each type of chipless tag are discussed. Two types of 5-bit chipless tag examples are given with good consistent simulated and measured results. In addition, for the second-order chipless tag, we propose a miniaturization scheme, enhancing the anti-damage ability simultaneously. Damage test shows that the second-order chipless tags have the good anti-damage ability, especially for the miniaturized tag. Finally, the bit-extension by the formulaic method is discussed, emphasizing the promising practicability.
20 May 2024 in IEEE Transactions on Antennas and Propagation
In this paper, a multifunctional polarization conversion metasurface (MPCM) has been proposed that can switch between seven different transmissive and reflective polarization conversion modes. The basic unit cell consists of three layers of split square rings (SSR) separated by two substrates, and a PIN diode is embedded in the top SSR to dynamically control asymmetric transmission and reflection responses. The layer-by-layer design guideline is provided with the polarization conversion mechanism illustrated. A prototype made up of 20 × 20 units was fabricated and measured. The measurement and simulation results demonstrate the versatile polarization conversions including co-polarization reflection, cross-polarization transmission, and circular polarization reflection and transmission, depending on the incident x - and y -polarized waves forward and backward. Significantly, the performance of the MPCM keeps excellent in a large oblique angle range of 50°. The MPCM synthesized from the single SSR layers provides an idea for general transmissive and reflective metasurface design, which is expected to be applied in the fields of radar and wireless communications.
As narcotic control has become worse in the past decade and the death toll of drug abuse hits a record high, there is an increasing demand for on-site rapid detection of illegal drugs. This work developed a portable digital linear ion trap mass spectrometer based on separate-region corona discharge ionization source to meet this need. A separate design of discharge and reaction regions was adopted with filter air as both carrier gas for the analyte and protection of the corona discharge needle. The linear ion trap was driven by a digital waveform with a low voltage (±100 V) to cover a mass range of 50–500 Da with a unit resolution at a scan rate of 10,000 Da/s. Eighteen representative drugs were analyzed, demonstrating excellent qualitative analysis capability. Tandem mass spectrometry (MS/MS) was also performed by ion isolation and collision-induced dissociation (CID) with air as a buffer gas. With cocaine as an example, over two orders of magnitude dynamic range and 10 pg of detection limit were achieved. A single analysis time of less than 10 s was obtained by comparing the information of characteristic ions and product ions with the built-in database. Analysis of a real-world sample further validated the feasibility of the instrument, with the results benchmarked by GC-MS. The developed system has powerful analytical capability without using consumables including solvent and inert gas, meeting the requirements of on-site rapid detection applications.
24 February 2025 in IEEE Transactions on Instrumentation and Measurement
In this paper, a novel multifrequency microwave sensor comprising four interdigital split ring resonators (SRRs) coupled to a microstrip feed line is proposed for measuring types and volume fractions of liquids. The interdigital SRR is based on a traditional SRR with its split replaced by an interdigital capacitor (IDC) structure. The IDC in the SRR, serving as the sensing region, has strong electric fields, highly responsive to variations in the dielectric properties of the sample. To mitigate the influence of the sample on the microstrip feed line, a ground plane is inserted between the feed line and sensing region. Different samples exhibit distinct resonant frequencies and transmission magnitude of the sensor, which are used to invert their complex permittivity through a mathematical relationship model. Subsequently, liquid types and concentrations can be identified based on a pre-established knowledge database. Significantly, the four-resonance frequency measurement enables to determine the dielectric dispersion of the liquids over the 2–6 GHz range, enhancing identification accuracy through the nearest neighbor search principle. Experiments conducted with various liquid types and ethanol solutions of varying concentrations demonstrate the superior identification capability of the sensor. The sensor’s compact size, simple structure, and high identification accuracy highlight its potential for on-site, real-time, non-invasive detection applications.
Lung adenocarcinoma is the most common pathological type of lung cancer with poor patient outcomes; therefore, developing novel therapeutic agents is critically needed. Andrographolide (AD), a major active component derived from the traditional Chinese medicine (TCM) Andrographis paniculate, is a potential antitumor drug, but the role of AD in lung adenocarcinoma remains poorly understood. In the present study, we demonstrated that AD inhibited the proliferation of broad-spectrum lung cancer cell lines in a dose-dependent manner. Meanwhile, we found that a high dose of AD induced Noxa-dependent apoptosis in human lung adenocarcinoma cells (A549 and H1299). Further studies revealed that Noxa was transcriptionally activated by activating transcription factor 4 (ATF4) in AD-induced apoptosis. Knockdown of ATF4 by small interfering RNA (siRNA) significantly diminished the transactivation of Noxa as well as the apoptotic population induced by AD. These results of the present study indicated that AD induced apoptosis of human lung adenocarcinoma cells by activating the ATF4/Noxa axis and supporting the development of AD as a promising candidate for the new era of chemotherapy.