Xingli He

Dr. Xingli He


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2022 in Molecules
Verified
Journal Article
Open access
PDF file
LLLingfeng Li
Lingfeng Li
TZTianyi Zhang
Tianyi Zhang
DWDeting Wang
Deting Wang
YZYunjing Zhang
Yunjing Zhang
XHXingli He
Xingli He
PLPeng Li
Peng Li
As narcotic control has become worse in the past decade and the death toll of drug abuse hits a record high, there is an increasing demand for on-site rapid detection of illegal drugs. This work developed a portable digital linear ion trap mass spectrometer based on separate-region corona discharge ionization source to meet this need. A separate design of discharge and reaction regions was adopted with filter air as both carrier gas for the analyte and protection of the corona discharge needle. The linear ion trap was driven by a digital waveform with a low voltage (±100 V) to cover a mass range of 50–500 Da with a unit resolution at a scan rate of 10,000 Da/s. Eighteen representative drugs were analyzed, demonstrating excellent qualitative analysis capability. Tandem mass spectrometry (MS/MS) was also performed by ion isolation and collision-induced dissociation (CID) with air as a buffer gas. With cocaine as an example, over two orders of magnitude dynamic range and 10 pg of detection limit were achieved. A single analysis time of less than 10 s was obtained by comparing the information of characteristic ions and product ions with the built-in database. Analysis of a real-world sample further validated the feasibility of the instrument, with the results benchmarked by GC-MS. The developed system has powerful analytical capability without using consumables including solvent and inert gas, meeting the requirements of on-site rapid detection applications.

24 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JYJing Lei Yong
Jing Lei Yong
PLPeng Li
Peng Li
XHXingli He
Xingli He
MTMei Song Tong
Mei Song Tong
LGLe Tian Guo
Le Tian Guo
YZYunjing Zhang
Yunjing Zhang
In this paper, a novel multifrequency microwave sensor comprising four interdigital split ring resonators (SRRs) coupled to a microstrip feed line is proposed for measuring types and volume fractions of liquids. The interdigital SRR is based on a traditional SRR with its split replaced by an interdigital capacitor (IDC) structure. The IDC in the SRR, serving as the sensing region, has strong electric fields, highly responsive to variations in the dielectric properties of the sample. To mitigate the influence of the sample on the microstrip feed line, a ground plane is inserted between the feed line and sensing region. Different samples exhibit distinct resonant frequencies and transmission magnitude of the sensor, which are used to invert their complex permittivity through a mathematical relationship model. Subsequently, liquid types and concentrations can be identified based on a pre-established knowledge database. Significantly, the four-resonance frequency measurement enables to determine the dielectric dispersion of the liquids over the 2–6 GHz range, enhancing identification accuracy through the nearest neighbor search principle. Experiments conducted with various liquid types and ethanol solutions of varying concentrations demonstrate the superior identification capability of the sensor. The sensor’s compact size, simple structure, and high identification accuracy highlight its potential for on-site, real-time, non-invasive detection applications.

27 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LLLingfeng Li
Lingfeng Li
HGHao Gu
Hao Gu
YLYanzhen Lv
Yanzhen Lv
YZYunjing Zhang
Yunjing Zhang
XHXingli He
Xingli He
PLPeng Li
Peng Li
Drift-time ion mobility spectrometer (DT-IMS) is a promising technology for gas detection and analysis in the form of miniaturized instrument. Analytes may exist in the form of positively or negatively charged ions according to their chemical composition and ionization condition, and therefore require both polarity of electric field for the detection. In this work the polarity switching of a drift-time ion mobility spectrometer based on a direct current (DC) corona discharge ionization source was investigated, with novel solutions for both the control of ion shutter and the stabilization of aperture grid. The drift field is established by employing a switchable high voltage power supply and a serial of voltage regulator diode, with optocouplers to drive the ion shutter when the polarity is switched. The potential of aperture grid is stabilized during the polarity switching by the use of four diodes to avoid unnecessary charging cycle of the aperture grid capacitor. Based on the proposed techniques, the developed DT-IMS with 50 mm drift path is able to switch its polarity in 10 ms and acquire mobility spectrum after 10 ms of stabilization. Coupled with a thermal desorption sampler, limit of detection (LoD) of 0.1 ng was achieved for ketamine and TNT. Extra benefits include single calibration substance for both polarities and largely simplified pneumatic design, together with the reduction of second drift tube and its accessories. This work paved the way towards further miniaturization of DT-IMS without compromise of performance.

17 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
LLLingfeng Li
Lingfeng Li
TZTianyi Zhang
Tianyi Zhang
WGWei Ge
Wei Ge
XHXingli He
Xingli He
YZYunjing Zhang
Yunjing Zhang
PLPeng Li
Peng Li
A novel sample introduction and ionization method for trace explosives detection is proposed and investigated herein, taking into consideration real-world application requirements. A thermal desorption sampling method and dielectric barrier discharge ionization (DBDI) source, with air as the discharge gas, were developed. The counter flow method was adopted firstly into the DBDI source to remove the interference of ozone and other reactive nitrogen oxides. A separated reaction region with an ion guiding electric field was developed for ionization of the sample molecules. Coupled with a homemade miniature digital linear ion trap mass spectrometer, this compact and robust design, with further optimization, has the advantages of soft ionization, a low detection limit, is free of reagent and consumable gas, and is an easy sample introduction. A range of common nitro-based explosives including TNT, 2,4-DNT, NG, RDX, PETN, and HMX has been studied. A linear response in the range of two orders of magnitude with a limit of detection (LOD) of 0.01 ng for TNT has been demonstrated. Application to the detection of real explosives and simulated mixed samples has also been explored. The work paves the path to developing next generation mass spectrometry (MS) based explosive trace detectors (ETDs).

30 November 2021 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
XHXingli He
Xingli He
JZJian Zhou
Jian Zhou
WXWeipeng Xuan
Weipeng Xuan
ZZZhengjia Zhan
Zhengjia Zhan
YZYunjing Zhang
Yunjing Zhang
LKLinghui Kong
Linghui Kong
Ultrahigh-frequency surface acoustic wave (SAW) devices with high quality ( $Q$ ) factors are essential components for the next-generation wireless communication system. In this work, we reported high-performance and ultrahigh-frequency SAW devices with single-crystalline LiTaO 3 /SiO 2 /Si [LT-on-insulator (LTOI)] multilayered heterostructure. The fabricated SAW resonators exhibited multi-resonant modes (Rayleigh, Sezawa, and LLSAW mode) with the frequency ranging from 1.81 to 8.33 GHz. Especially, the SAW resonator with the Rayleigh wave frequency over 5.0 GHz and high $Q$ value around 2300 with a wavelength of 600 nm was realized. The variation of the phase velocity, the $Q$ factor for each resonant mode, and the effective coupling coefficients ( $k^{2}_{\mathrm {eff}}$ ) versus the normalized LiTaO 3 film thickness were systematically investigated. The proposed high-frequency SAW based on LTOI multilayered heterostructure possesses the low temperature coefficient of frequency (TCF, −20 ppm/K). Furthermore, a high-performance SAW bandpass filter with the center frequency of ~3.5 GHz was achieved. The work shows the great potential of the LiTaO 3 single-crystalline thin-films-based SAW for ultrahigh frequency electronics applications.

9 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JGJunwei Gu
Junwei Gu
XHXingli He
Xingli He
SJShuyue Jin
Shuyue Jin
YZYunjing Zhang
Yunjing Zhang
LLLingfeng Li
Lingfeng Li
PLPeng Li
Peng Li
This work presents the fabrication and characterization of a sub-GHz plate-wave-based pressure sensor relying on an ultra-thin (360 nm) single-crystalline LiNbO 3 film. The proposed devices exhibit multiple resonant modes which are characterized and analyzed by a precise 3D plate wave resonator model based on finite element analysis (FEA). Generally, the main resonant modes correspond to the Shear-horizontal ( SH ) and anti-symmetric ( A ) Lamb waves. To overcome the high-temperature coefficient of LiNbO 3 thin film, a thick layer (~4 μm) of SiO 2 was used to compensate for the temperature drift of the devices; the calculated temperature coefficients of frequency ( TCFs ) for the multi-resonant modes are lower than -27 ppm/K. The frequency and return loss (S 11 ) shift of the plate wave devices, the pressure sensitivity, and the pressure coefficient of frequency ( PCF ) were experimentally evaluated and analyzed. All the resonant modes show high PCF even with relatively lower operating frequencies (< 1 GHz). Especially it has been observed that the first-order anti-symmetric (A1) Lamb wave is ultra-susceptible to pressure changes, which presented a record high value of ~600 ppm/Bar and excellent linearity over the tested 0.6 to 1.8 Bar pressure range. The results show that the developed sensor has sufficiently high sensitivity and can be used for precise absolute pressure sensing.