Objective: The study aims to evaluate the wear surface using 3D surface roughness and other material characterization of zirconia fabricated using photopolymerization based Lithography-based Ceramic Manufacturing (LCM). Method: LCM technology was used to fabricate zirconia specimens of size 10 × 10 × 2mm3. Scanning Electron Microscope, 3D–profilometer, X-ray Diffraction, and hardness test characterized the samples before and after wear and Coefficient of friction (COF) was monitored. Result: The COF was around 0.7 and did not differ much between the horizontally and vertically printed specimens. However, the surface roughness after wear for horizontally printed specimen was 0.567 ± 0.139 μm, while that for vertically printed specimen was 0.379 ± 0.080 μm. The reduced valley depth and the dale void volume were low for the vertically printed zirconia specimen, indicating lesser voids and low fluid retention. In addition, it was observed that the hardness value of the vertically printed sample was better. The scanning electron microscopic images and 3D surface profiles of the zirconia specimens depicted the surface topography and revealed the wear track. Conclusion: The study shows that zirconia fabricated using LCM technology possesses surface roughness of about 0.5 μm with no machining scars that are usually associated with CAD/CAM dentistry and also indicating agreement with clinically acceptable values for minimal surface roughness of dental restorations. Dental restorations using LCM fabricated zirconia redues the requirement of post-processing work flow that is part of CAD/CAM dentistry.
Objective: Pseudarthrosis and adjacent segment degeneration (ASD) are 2 common complications after multilevel anterior cervical discectomy and fusion (ACDF). We aim to identify the potential biomechanical factors contributing to pseudarthrosis and ASD following 3-level ACDF using a cervical spine finite element model (FEM).Methods: A validated cervical spine FEM from C2 to C7 was used to study the biomechanical factors in cervical spine intervention. The FEM model was used to simulate a 3-level ACDF with intervertebral spacers and anterior cervical plating with screw fixation from C4 to C7. The model was then constrained at the inferior nodes of the T1 vertebra, and physiological loads were applied at the top vertebra. The pure moment load of 2 Nm was applied in flexion, extension, and lateral bending. A follower axial force of 75 N was applied to reproduce the weight of the cranium and muscle force, was applied using standard procedures. The motion-controlled hybrid protocol was utilized to comprehend the adjustments in the spinal biomechanics.Results: Our cervical spine FEM demonstrated that the cranial adjacent level (C3–4) had significantly more increase in range of motion (ROM) (+90.38%) compared to the caudal adjacent level at C7–T1 (+70.18%) after C4–7 ACDF, indicating that the cranial adjacent level has more compensatory increase in ROM than the caudal adjacent level, potentially predisposing it to earlier ASD. Within the C4–7 ACDF construct, the C6–7 level had the least robust fixation during fixation compared to C4–5 and C5–6, as reflected by the smallest reduction in ROM compared to intact spine (-71.30% vs. -76.36% and -77.05%, respectively), which potentially predisposes the C6–7 level to higher risk of pseudarthrosis.Conclusion: Biomechanical analysis of C4–7 ACDF construct using a validated cervical spine FEM indicated that the C3–4 has more compensatory increase in ROM compared to C7–T1, and C6–7 has the least robust fixation under physiological loads. These findings can help spine surgeons to predicate the areas with higher risks of pseudarthrosis and ASD, and thus developing corresponding strategies to mitigate these risks and provide appropriate preoperative counseling to patients.
16 July 2019 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
The Automotive Seating System (ASS) is an important sub-system in a car for increasing the ride comfort of driver/occupant and hence the need for a systematic study on the vibration characteristics of ASS is of importance. The present study finds out the vibration characteristics of four models of automotive seating system, with and without dummy mass using finite element analysis. The vibration mode shapes such as lateral, fore-aft and twisting of automotive seating system found in the frequency range 0-80 Hz for the four models of automotive seating system and correlated with experimental results found in the literature. The natural frequency of the seat with dummy mass was found to be in the human discomfort zone of the spinal column (10–12 Hz) and abdomen (4–8 Hz). The vibration transfer to occupant body was studied at 11 positions, with unit acceleration given at four mounting locations of automotive seating system in three directions separately. The vibration transmissibility was found to be higher than one in seat backrest. The random vibration analysis was carried out to identify the acceleration level of automotive seating system, subjected to smooth and rough road excitations. In the case of rough road random excitations, the results of root mean square acceleration values in automotive seating system show that the driver/passenger feels “fairly comfortable”. This study emphasizes the importance of the ride comfort of driver/occupant. To enhance the ride comfort, the stiffness of seat structure has to be modified and suspension system has to be introduced.
28 August 2019 in International Journal of Dynamics and Control