Priscilla G Baker

Prof. Priscilla G Baker

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2015 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
FMFrancis Ntumba Muya
Francis Ntumba Muya
MWMeryck Ward
Meryck Ward
CSChristopher Edoze Sunday
Christopher Edoze Sunday
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha
Heavy metal ions such as Cd2+, Pb2+, Cu2+, Mg2+, and Hg2+ from industrial waste water constitute a major cause of pollution for ground water sources. These ions are toxic to man and aquatic life as well, and should be removed from wastewater before disposal. Various treatment technologies have been reported to remediate the potential toxic elements from aqueous media such as adsorption, precipitation and coagulation. Most of these technologies are associated with some shortcomings, and challenges in terms of applicability, effectiveness and cost. However adsorption techniques have the capability of effectively removing heavy metals at very low concentration (1–100 mg/L). Various adsorbents have been reported in the literature for this purpose, including to a lesser extent, the use of hydrogel adsorbents for heavy metal removal in aqueous phase. Here, we provide an in depth perspective on the design, application and efficiency of hydrogel systems as adsorbents.

1 April 2011 in Sensors
Verified
Journal Article
Open access
PDF file
CWChandre M. Willemse
Chandre M. Willemse
KTKhotso Tlhomelang
Khotso Tlhomelang
NJNazeem Jahed
Nazeem Jahed
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha
A Nafion-Graphene (Nafion-G) nanocomposite solution in combination with an in situ plated mercury film electrode was used as a highly sensitive electrochemical platform for the determination of Zn2+, Cd2+, Pb2+ and Cu2+ in 0.1 M acetate buffer (pH 4.6) by square-wave anodic stripping voltammetry (SWASV). Various operational parameters such as deposition potential, deposition time and electrode rotation speed were optimized. The Nafion-G nanocomposite sensing platform exhibited improved sensitivity for metal ion detection, in addition to well defined, reproducible and sharp stripping signals. The linear calibration curves ranged from 1 µg L−1 to 7 µg L−1 for individual analysis. The detection limits (3σ blank/slope) obtained were 0.07 µg L−1 for Pb2+, Zn2+ and Cu2+ and 0.08 µg L−1 for Cd2+ at a deposition time of 120 s. For practical applications recovery studies was done by spiking test samples with known concentrations and comparing the results with inductively coupled plasma mass spectrometry (ICP-MS) analyses. This was followed by real sample analysis.

1 March 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Abdellatif Ait LahcenAbdellatif Ait Lahcen
Abdellatif Ait Lahcen
ABAbd Almonam Baleg
Abd Almonam Baleg
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha
AAAziz Amine
Aziz Amine

15 December 2008 in Sensors
Verified
Journal Article
Open access
PDF file
JOJoseph H.O. Owino
Joseph H.O. Owino
Omotayo ArotibaOmotayo Arotiba
Omotayo Arotiba
NHNicolette Hendricks
Nicolette Hendricks
ESEverlyne A. Songa
Everlyne A. Songa
NJNazeem Jahed
Nazeem Jahed
EIEmmanuel Iwuoha
Emmanuel Iwuoha
An aflatoxin B1 (AFB1) electrochemical immunosensor was developed by the immobilisation of aflatoxin B1-bovine serum albumin (AFB1-BSA) conjugate on a polythionine (PTH)/gold nanoparticles (AuNP)-modified glassy carbon electrode (GCE). The surface of the AFB1-BSA conjugate was covered with horseradish peroxidase (HRP), in order to prevent non-specific binding of the immunosensors with ions in the test solution. The AFB1 immunosensor exhibited a quasi-reversible electrochemistry as indicated by a cyclic voltammetric (CV) peak separation (ΔEp) value of 62 mV. The experimental procedure for the detection of AFB1 involved the setting up of a competition between free AFB1 and the immobilised AFB1-BSA conjugate for the binding sites of free anti-aflatoxin B1 (anti-AFB1) antibody. The immunosensor’s differential pulse voltammetry (DPV) responses (peak currents) decreased as the concentration of free AFB1 increased within a dynamic linear range (DLR) of 0.6 - 2.4 ng/mL AFB1 and a limit of detection (LOD) of 0.07 ng/mL AFB1. This immunosensing procedure eliminates the need for enzyme-labeled secondary antibodies normally used in conventional ELISA–based immunosensors.

1 June 2009 in Bioelectrochemistry
Verified
Journal Article
Closed access
ESEverlyne A. Songa
Everlyne A. Songa
Omotayo ArotibaOmotayo Arotiba
Omotayo Arotiba
JOJoseph H.O. Owino
Joseph H.O. Owino
NJNazeem Jahed
Nazeem Jahed
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha

3 November 2010 in Sensors
Verified
Journal Article
Open access
PDF file
RORasaq A. Olowu
Rasaq A. Olowu
Omotayo ArotibaOmotayo Arotiba
Omotayo Arotiba
SMStephen Nzioki Mailu
Stephen Nzioki Mailu
TWTesfaye T. Waryo
Tesfaye T. Waryo
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha
A simple and highly sensitive electrochemical DNA aptasensor with high affinity for endocrine disrupting 17β-estradiol, was developed. Poly(3,4-ethylenedioxylthiophene) (PEDOT) doped with gold nanoparticles (AuNPs) was electrochemically synthesized and employed for the immobilization of biotinylated aptamer towards the detection of the target. The diffusion coefficient of the nanocomposite was 6.50 × 10−7 cm2 s−1, which showed that the nanocomposite was highly conducting. Electrochemical impedance investigation also revealed the catalytic properties of the nanocomposite with an exchange current value of 2.16 × 10−4 A, compared to 2.14 × 10−5 A obtained for the bare electrode. Streptavidin was covalently attached to the platform using carbodiimide chemistry and the aptamer immobilized via streptavidin—biotin interaction. The electrochemical signal generated from the aptamer–target molecule interaction was monitored electrochemically using cyclic voltammetry and square wave voltammetry in the presence of [Fe(CN)6]−3/−4 as a redox probe. The signal observed shows a current decrease due to interference of the bound 17β-estradiol. The current drop was proportional to the concentration of 17β-estradiol. The PEDOT/AuNP platform exhibited high electroactivity, with increased peak current. The platform was found suitable for the immobilization of the DNAaptamer. The aptasensor was able to distinguish 17β-estradiol from structurally similar endocrine disrupting chemicals denoting its specificity to 17β-estradiol. The detectable concentration range of the 17β-estradiol was 0.1 nM–100 nM, with a detection limit of 0.02 nM.