Nazeem Jahed

Dr. Nazeem Jahed


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2004 in Macromolecules
Verified
Journal Article
Closed access
MLMei Li
Mei Li
NJNazeem Jahed
Nazeem Jahed
KMKe Min
Ke Min
KMKrzysztof Matyjaszewski
Krzysztof Matyjaszewski

30 September 2005 in Macromolecules
Verified
Journal Article
Closed access
HGHaifeng Gao
Haifeng Gao
GLGuillaume Louche
Guillaume Louche
BSBrent S. Sumerlin
Brent S. Sumerlin
NJNazeem Jahed
Nazeem Jahed
PGPatricia Golas
Patricia Golas
KMKrzysztof Matyjaszewski
Krzysztof Matyjaszewski

1 April 2011 in Sensors
Verified
Journal Article
Open access
PDF file
CWChandre M. Willemse
Chandre M. Willemse
KTKhotso Tlhomelang
Khotso Tlhomelang
NJNazeem Jahed
Nazeem Jahed
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha
A Nafion-Graphene (Nafion-G) nanocomposite solution in combination with an in situ plated mercury film electrode was used as a highly sensitive electrochemical platform for the determination of Zn2+, Cd2+, Pb2+ and Cu2+ in 0.1 M acetate buffer (pH 4.6) by square-wave anodic stripping voltammetry (SWASV). Various operational parameters such as deposition potential, deposition time and electrode rotation speed were optimized. The Nafion-G nanocomposite sensing platform exhibited improved sensitivity for metal ion detection, in addition to well defined, reproducible and sharp stripping signals. The linear calibration curves ranged from 1 µg L−1 to 7 µg L−1 for individual analysis. The detection limits (3σ blank/slope) obtained were 0.07 µg L−1 for Pb2+, Zn2+ and Cu2+ and 0.08 µg L−1 for Cd2+ at a deposition time of 120 s. For practical applications recovery studies was done by spiking test samples with known concentrations and comparing the results with inductively coupled plasma mass spectrometry (ICP-MS) analyses. This was followed by real sample analysis.

15 December 2008 in Sensors
Verified
Journal Article
Open access
PDF file
JOJoseph H.O. Owino
Joseph H.O. Owino
Omotayo ArotibaOmotayo Arotiba
Omotayo Arotiba
NHNicolette Hendricks
Nicolette Hendricks
ESEverlyne A. Songa
Everlyne A. Songa
NJNazeem Jahed
Nazeem Jahed
EIEmmanuel Iwuoha
Emmanuel Iwuoha
An aflatoxin B1 (AFB1) electrochemical immunosensor was developed by the immobilisation of aflatoxin B1-bovine serum albumin (AFB1-BSA) conjugate on a polythionine (PTH)/gold nanoparticles (AuNP)-modified glassy carbon electrode (GCE). The surface of the AFB1-BSA conjugate was covered with horseradish peroxidase (HRP), in order to prevent non-specific binding of the immunosensors with ions in the test solution. The AFB1 immunosensor exhibited a quasi-reversible electrochemistry as indicated by a cyclic voltammetric (CV) peak separation (ΔEp) value of 62 mV. The experimental procedure for the detection of AFB1 involved the setting up of a competition between free AFB1 and the immobilised AFB1-BSA conjugate for the binding sites of free anti-aflatoxin B1 (anti-AFB1) antibody. The immunosensor’s differential pulse voltammetry (DPV) responses (peak currents) decreased as the concentration of free AFB1 increased within a dynamic linear range (DLR) of 0.6 - 2.4 ng/mL AFB1 and a limit of detection (LOD) of 0.07 ng/mL AFB1. This immunosensing procedure eliminates the need for enzyme-labeled secondary antibodies normally used in conventional ELISA–based immunosensors.

1 June 2009 in Bioelectrochemistry
Verified
Journal Article
Closed access
ESEverlyne A. Songa
Everlyne A. Songa
Omotayo ArotibaOmotayo Arotiba
Omotayo Arotiba
JOJoseph H.O. Owino
Joseph H.O. Owino
NJNazeem Jahed
Nazeem Jahed
PBPriscilla G Baker
Priscilla G Baker
EIEmmanuel Iwuoha
Emmanuel Iwuoha

8 March 2004 in Journal of Polymer Science Part A: Polymer Chemistry
Verified
Journal Article
Closed access
PDF file
JLJean‐François Lutz
Jean‐François Lutz
NJNazeem Jahed
Nazeem Jahed
Krzysztof MatyjaszewskiKrzysztof Matyjaszewski
Krzysztof Matyjaszewski