Dong Wei

Prof. Dr. Dong Wei

Hunan University, Changsha, Guangdong, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Dong WeiDong Wei
Dong Wei
Kan LiuKan Liu
Kan Liu
Wei HuWei Hu
Wei Hu
XPXiaoyan Peng
Xiaoyan Peng
YCYongdan Chen
Yongdan Chen
RDRongjun Ding
Rongjun Ding
Inter-turn short circuit (ITSC) is a common fault in electrical machines, which may result in further devastation to the whole winding and magnets. In this article, a method for real-time residual insulation capacity monitoring of ITSC fault in permanent magnet synchronous machines (PMSMs) is proposed, which is robust to speed/torque variation and independent of machine parameters and extra sensors. It is based on the theory that the ITSC fault initiates as an insulation deterioration among adjacent turns and the fault severity can be described by the residual insulation capacity being relevant to the 2nd harmonic component in the dq -axis currents. Thus, a short-time Adaline-based harmonic extraction method is proposed for the separation of the needed 2nd harmonic component from time-varying current signals, being used as the fault indicator afterward. Finally, the performance of the proposed method is experimentally evaluated on a PMSM and shows quite good performance in fast-tracking and detection of faults in various stages.

25 September 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Dong WeiDong Wei
Dong Wei
Kan LiuKan Liu
Kan Liu
JWJianbo Wang
Jianbo Wang
SZShichao Zhou
Shichao Zhou
KLKaiqing Li
Kaiqing Li
A ResNet-18 based model for the online inter-turn short circuit (ITSC) fault diagnosis of PMSMs widely employed in traction systems of electric vehicles and locomotives is proposed in this paper, which is a data-driven solution and robust to bandwidth variation in both speed and current controllers. It is found that the extracted fault features at the early stage of the ITSC are usually quite small and will be significantly influenced by the bandwidths of both speed and current controllers, which will potentially lead to a misjudgment of fault degree. Hence, a ResNet-18 deep learning model for ITSC fault is designed in this paper, which has considered the variation of bandwidths of speed and current controllers by improving the input of the network. It can accurately detect and classify the fault degrees concerning adjacent levels of insulation deterioration thanks to its high performance in feature representation. Multivariate signals including speed, dq -axis currents, and reference voltages are employed as inputs with five channels to train the proposed diagnostic model, which can be easily measured from the PMSM drive system. The diagnosis results of ITSC fault on a prototype PMSM show a high average accuracy being up to 97.81%.

22 September 2023 in IEEE Access
Verified
Journal Article
Open access
YLYunfeng Liu
Yunfeng Liu
Kan LiuKan Liu
Kan Liu
YZYunshan Zhou
Yunshan Zhou
YCYongdan Chen
Yongdan Chen
Dong WeiDong Wei
Dong Wei
HLHaozhe Luan
Haozhe Luan
In order to develop continuously variable transmission (CVT) suited for electric vehicle (EV), a comparative analysis of the transmission used on EV is introduced in this paper. To solve the problems of traditional CVT used for EV, a newly designed electric CVT (ECVT) is proposed. The final drive ratio, speed ratio range of variator and hydraulic system of ECVT are redesigned for improving the transmission efficiency. Considering that the permanent magnet synchronization traction motor (PMSTM) of EV has an ideal driving characteristic (Constant torque at low speed, constant power at high speed) and wider high efficiency area compared with gasoline engine, the speed ratio control strategy of ECVT is studied again for improving the vehicle driving range and better meeting the requirements of driver. Finally, a simulation test system is fabricated for evaluating the battery energy consumption of an EV equipped with ECVT and single-speed transmission (SST) under constant speed and road drive cycle. The simulation results show that the ECVT proposed can extend the endurance mileage of EV at the speed of 20 to 90km/h, and improve the acceleration performance from 0 to 50km/h. The EV equipped with ECVT showed more advantages compared with SST in urban conditions.

3 February 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
JWJianbo Wang
Jianbo Wang
Kan LiuKan Liu
Kan Liu
Dong WeiDong Wei
Dong Wei
YCYongdan Chen
Yongdan Chen
JCJinya Chen
Jinya Chen
JZJing Zhou
Jing Zhou
In this article, a multielectrical signal fusion method based on the rotor speed and stator current is investigated for bearing fault diagnosis of permanent magnet synchronous machines (PMSMs) under variable speed conditions. This method can achieve low-cost and real-time fault diagnosis by using directly measured rotor speed and stator current signals from the drive machine of the mechatronics system. First, the fault feature harmonic can be extracted from the rotor speed signal, and the instantaneous phase is estimated using the stator current of PMSMs. The time-domain fault feature harmonic is then resampled on the angle domain using a high-precision accumulative angle calculated by the instantaneous phase. Finally, the fault type can be diagnosed by the fault indicator in the envelope spectrum of the resampled signal. Furthermore, experimental validations are conducted on the PMSM-drive-system-based bearing fault diagnosis platform. The results indicate that the proposed method can accurately extract fault features to diagnose the bearing faults under variable speed conditions without extra sensors.

15 October 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Dong WeiDong Wei
Dong Wei
Kan LiuKan Liu
Kan Liu
Jing HuangJing Huang
Jing Huang
JWJianbo Wang
Jianbo Wang
SZShichao Zhou
Shichao Zhou
JCJinya Chen
Jinya Chen
Inter-turn short circuit fault is a commonly occurring electrical fault in permanent magnet synchronous machines (PMSMs) with serious consequences. Diagnostic methods under non-stationary operating conditions lie in removing the impact of speed variations, hence the rotational speed signal is essential. In addition, another signal containing the fault feature information is also needed. However, to reduce the amount of data transmitted from the slave device to the host computer, or deal with signal transmission failure and sensor failure to strengthen the reliability, a single signal based diagnostic method is proposed, which only requires any one of the dq-axis signal, speed, or phase current, even under variable speed conditions. The instantaneous phase is estimated using the single signal based on an intrinsic harmonic feature of the tested machine, and angular resampling is then implemented on the signal based on the fault model. The proposed method is eventually tested on a PMSM using dq-axis signal, speed, and phase current, respectively. The results show that the estimation error of the instantaneous phase using any signal is less than 1.13%, and accurate fault feature extraction is achieved under different speed conditions.

1 July 2024 in IET Electric Power Applications
Verified
Journal Article
Open access
Dong WeiDong Wei
Dong Wei
Kan LiuKan Liu
Kan Liu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
SZShichao Zhou
Shichao Zhou
JWJianbo Wang
Jianbo Wang
YCYongdan Chen
Yongdan Chen
A rotor speed signature analysis‐ (RSSA‐)based inter‐turn short circuit (ITSC) fault diagnostic method is proposed, which is robust with regard to speed‐ and current‐loop bandwidths of permanent magnet synchronous machine (PMSM) drive systems. Conventional ITSC fault detection solutions that rely on current signals or extra devices. Thus, an initial step of investigation on the validity of RSSA is taken for residual insulation capacity monitoring of the ITSC fault at the incipient stage. The Vold–Kalman filtering order tracking method is employed for the real‐time extraction of fault features. Besides, the impact of speed‐ and current‐loop controller bandwidths on ITSC fault diagnosis is also analysed and an Adaline estimator is designed to decouple their impacts. Finally, the effectiveness of the proposed method is verified on a faulty PMSM, which exhibits satisfying results in tracking the degradation of residual insulation, even if the phase currents are significantly distorted due to low switching frequency of the inverter.