Nishant Kumar Singh

Dr. Nishant Kumar Singh

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2022 in Coatings
Verified
Journal Article
Open access
PDF file
RVRati Verma
Rati Verma
JKJitendra Kumar
Jitendra Kumar
NSNishant Kumar Singh
Nishant Kumar Singh
SRSanjay Kumar Rai
Sanjay Kumar Rai
Kuldeep SAXENAKuldeep SAXENA
Kuldeep SAXENA
Jinyang XuJinyang Xu
Jinyang Xu
Gyroid (G) and primitive (P) porous structures have multiple application areas, ranging from thermal to mechanical, and fall in the complex triply periodic minimal surface (TPMS) category. Such intricate bioinspired constructs are gaining attention because they meet both biological and mechanical requirements for osseous reconstruction. The study aimed to develop G and P structures with varying porosity levels from 40% to 80% by modulating the strut thickness to proportionally resemble the stiffness of host tissue. The performance characteristics were evaluated using Ti6Al4V and important relationships between feature dimension, strut thickness, porosity, and stiffness were established. Numerical results showed that the studied porous structures could decrease stiffness from 107 GPa (stiffness of Ti6Al4V) to the range between 4.21 GPa to 29.63 GPa of varying porosities, which matches the human bone stiffness range. Furthermore, using this foundation, a subject-specific scaffold (made of P unit cells with an 80% porosity) was developed to reconstruct segmental bone defect (SBD) of the human femur, demonstrating a significant decrease in the stress shielding effect. Stress transfer on the bone surrounded by a P scaffold was compared with a solid implant which showed a net increase of stress transfer of 76% with the use of P scaffold. In the conclusion, future concerns and recommendations are suggested.

30 July 2023 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Closed access
PDF file
JKJitendra Kumar
Jitendra Kumar
NNNeelam Shobha Nirala
Neelam Shobha Nirala
NSNishant Kumar Singh
Nishant Kumar Singh
NGNakul Gupta
Nakul Gupta
YDYagya Dutta Dwivedi
Yagya Dutta Dwivedi
MGManish Gupta
Manish Gupta

31 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
NSNitesh Kumar Singh
Nitesh Kumar Singh
NSNishant Kumar Singh
Nishant Kumar Singh
RVRati Verma
Rati Verma
ADAshish D. Diwan
Ashish D. Diwan
(1) Background: Intervertebral disc degeneration has been linked to obesity; its potential mechanical effects on the intervertebral disc remain unknown. This study aimed to develop and validate a patient-specific model of L3–L4 vertebrae and then use the model to estimate the impact of increasing body weight on disc degeneration. (2) Methods: A three-dimensional model of the functional spinal unit of L3–L4 vertebrae and its components were developed and validated. Validation was achieved by comparing the range of motions (RoM) and intradiscal pressures with the previous literature. Subsequently, the validated model was loaded according to the body mass index and estimated stress, deformation, and RoM to assess disc degeneration. (3) Results: During validation, L3–L4 RoM and intradiscal pressures: flexion 5.17° and 1.04 MPa, extension 1.54° and 0.22 MPa, lateral bending 3.36° and 0.54 MPa, axial rotation 1.14° and 0.52 MPa, respectively. When investigating the impact of weight on disc degeneration, escalating from normal weight to obesity reveals an increased RoM, by 3.44% during flexion, 22.7% during extension, 29.71% during lateral bending, and 33.2% during axial rotation, respectively. Also, stress and disc deformation elevated with increasing weight across all RoM. (4) Conclusions: The predicted mechanical responses of the developed model closely matched the validation dataset. The validated model predicts disc degeneration under increased weight and could lay the foundation for future recommendations aimed at identifying predictors of lower back pain due to disc degeneration.

14 February 2022 in Advances in Materials and Processing Technologies
Verified
Journal Article
Closed access
NSNitesh Kumar Singh
Nitesh Kumar Singh
NSNishant Kumar Singh
Nishant Kumar Singh
DPDhiren Pandit
Dhiren Pandit
Kuldeep SAXENAKuldeep SAXENA
Kuldeep SAXENA
Metals, ceramics and polymers are the three broad categories of bio-materials utilised in spinal fusion devices. A bio-material with good tensile strength, bio-compatible, minimal imaging artefacts, stiffness, young’s modulus near the bone and fatigue strength is suitable for a spinal fusion implant. Unfortunately, no material excels all desirable properties, such as high strength, similar elastic modulus to bone and excellent host tissue response. As a result, the materials used for such types of implants are identified by the unique criteria that are most significant and necessary for the implants specific applications. This may result in various components of a single implant being made of multi-materials to better fit its intended purpose. In fusion surgeries, implants and its fixation methods have advanced significantly to meet the demands of surgeons, who continue to increase their understanding of the bio-mechanical principles of spinal stability and help improve the production of novel implant design. The review focused on recent advancements and trends in the design of fusion devices and the use of bio-materials in their component assemblies. This review will help researchers to enhance and optimise the design and material properties for future spine implantology research.

15 March 2024
Verified
Book Chapter
Closed access
PDF file
ASAjay Kumar Sahu
Ajay Kumar Sahu
AKAman Khandwe
Aman Khandwe
JKJitendra Kumar
Jitendra Kumar
RVRati Verma
Rati Verma
NSNishant Kumar Singh
Nishant Kumar Singh

27 August 2024 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
RVRati Verma
Rati Verma
PKPradeep Kumar
Pradeep Kumar
NSNishant Kumar Singh
Nishant Kumar Singh
Degenerative disc disease is an increasing problematic complication following lumbar fusion surgeries. Posterior lumbar interbody fusion (PLIF) is a well-established surgical method for spine stability following intervertebral disc removal. The position and number of titanium cages in PLIF are remain contingent on individual surgeon experience. Thus, a systemic investigation of the efficacy of titanium single mega cage versus two cages in treating degenerative lumbar spinal diseases is imperative. A biomechanical study was aimed to compare the stability achieved in PLIF through interbody reconstruction using a single mega cage (32 mm) Vs. a dual cage (22 mm). Normal intact finite element model of L3–L4 was developed based on computed tomography images from a healthy 27-year-old male volunteer. The study tested the intact model (Model A) and its surgically operated counterparts using four PLIF implantation methods: single transverse cage (Model B), single transverse cage with bone graft (Model C), dual transverse cage (Model D), and dual transverse cage with bone graft (Model E). Combined loads simulating physiological motions—flexion, extension, axial rotation, and lateral bending —were applied across all loading directions. The assessment includes all model range of motion (ROM), micromotion between the cage and endplate, and stress on the cage and internal fixation system (screw and rod). The ROM between Models B, C, D and E were consistently reduced by over 71% compared to intact Model A under all motion scenarios. Model D exhibited the highest peak stress of 115 MPa on the cage during flexion, surpassing Model C and E (Flexion) by fourfold. Model E demonstrated the lowest cage stress (20 MPa) during extension, outperforming the other models. Notably, Model E exhibited minimal endplate stress (2 MPa), cage stress (21 MPa), micromotion (13 µm) during extension, and screw-rod stress (56 MPa) during flexion, making it superior to other implantation methods. In the context of PLIF, Model E showed enhanced biomechanical stability, reducing ROM, stress on the endplates, cage, screw-rod system and micromotion. Alternatively, Model C may be a viable alternative in standard PLIF, especially in cases with limited intervertebral space, providing efficient clinical outcomes with shorter operative times and reduced costs and ease of implantation. Also, this computational study provides valuable understandings into optimizing cage implantation strategies for improved outcomes during PLIF.