Nitesh Kumar Singh

Dr. Nitesh Kumar Singh

Biomedical Engineering, Mody University of Science and Technology, Lachhmangarh Sīkar, India
orcid
Assistant Professor

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
NSNitesh Kumar Singh
Nitesh Kumar Singh
NSNishant Kumar Singh
Nishant Kumar Singh
RVRati Verma
Rati Verma
ADAshish D. Diwan
Ashish D. Diwan
(1) Background: Intervertebral disc degeneration has been linked to obesity; its potential mechanical effects on the intervertebral disc remain unknown. This study aimed to develop and validate a patient-specific model of L3–L4 vertebrae and then use the model to estimate the impact of increasing body weight on disc degeneration. (2) Methods: A three-dimensional model of the functional spinal unit of L3–L4 vertebrae and its components were developed and validated. Validation was achieved by comparing the range of motions (RoM) and intradiscal pressures with the previous literature. Subsequently, the validated model was loaded according to the body mass index and estimated stress, deformation, and RoM to assess disc degeneration. (3) Results: During validation, L3–L4 RoM and intradiscal pressures: flexion 5.17° and 1.04 MPa, extension 1.54° and 0.22 MPa, lateral bending 3.36° and 0.54 MPa, axial rotation 1.14° and 0.52 MPa, respectively. When investigating the impact of weight on disc degeneration, escalating from normal weight to obesity reveals an increased RoM, by 3.44% during flexion, 22.7% during extension, 29.71% during lateral bending, and 33.2% during axial rotation, respectively. Also, stress and disc deformation elevated with increasing weight across all RoM. (4) Conclusions: The predicted mechanical responses of the developed model closely matched the validation dataset. The validated model predicts disc degeneration under increased weight and could lay the foundation for future recommendations aimed at identifying predictors of lower back pain due to disc degeneration.

9 September 2022 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
JKJitendra Kumar
Jitendra Kumar
RVRati Verma
Rati Verma
NSNitesh Kumar Singh
Nitesh Kumar Singh
NNNeelam Shobha Nirala
Neelam Shobha Nirala
SRSanjay Kumar Rai
Sanjay Kumar Rai

14 February 2022 in Advances in Materials and Processing Technologies
Verified
Journal Article
Closed access
NSNitesh Kumar Singh
Nitesh Kumar Singh
NSNishant Kumar Singh
Nishant Kumar Singh
DPDhiren Pandit
Dhiren Pandit
Kuldeep SAXENAKuldeep SAXENA
Kuldeep SAXENA
Metals, ceramics and polymers are the three broad categories of bio-materials utilised in spinal fusion devices. A bio-material with good tensile strength, bio-compatible, minimal imaging artefacts, stiffness, young’s modulus near the bone and fatigue strength is suitable for a spinal fusion implant. Unfortunately, no material excels all desirable properties, such as high strength, similar elastic modulus to bone and excellent host tissue response. As a result, the materials used for such types of implants are identified by the unique criteria that are most significant and necessary for the implants specific applications. This may result in various components of a single implant being made of multi-materials to better fit its intended purpose. In fusion surgeries, implants and its fixation methods have advanced significantly to meet the demands of surgeons, who continue to increase their understanding of the bio-mechanical principles of spinal stability and help improve the production of novel implant design. The review focused on recent advancements and trends in the design of fusion devices and the use of bio-materials in their component assemblies. This review will help researchers to enhance and optimise the design and material properties for future spine implantology research.

6 November 2017 in International Journal for Research in Applied Science and Engineering Technology
Verified
Journal Article
Closed access
NSNitesh Kumar Singh
Nitesh Kumar Singh

1 June 2025 in Physics of Fluids
Verified
Journal Article
Closed access
BBBratajit Basu
Bratajit Basu
DKDimpal Khambhati
Dimpal Khambhati
JKJitendra Kumar
Jitendra Kumar
NSNitesh Kumar Singh
Nitesh Kumar Singh
KDKhemraj Deshmukh
Khemraj Deshmukh
Cryptic pregnancy, characterized by the absence of typical gestational indicators, poses significant diagnostic challenges. Current diagnostic tests based on biochemical markers such as Human Chorionic Gonadotropin cannot detect such pregnancies because of hormonal dysregulation. The objective of the present study was to evaluate the variation in different rheological parameters—Pressure, Shear rate, Axial velocity—in the uterine arteries using the Computational Fluid Dynamics (CFD) using the COMSOL. The CFD analysis was performed on the total 24 geometries generated from the two structures: S1, before cryptic pregnancy and S2, after cryptic pregnancy. The CFD studies were performed in no slip condition of the wall and viscosity of flowing fluid (equivalent to blood), which were considered both Newtonian and non-Newtonian in the presence of sinusoidal and pulsatile flow. The different rheological parameters were observed on points P1–P5 at the T cycle. Result indicated that non-Newtonian flows exhibited dominant oscillatory patterns in shear rate, pressure, and axial velocity, especially at points like P2 and P4. Newtonian flows showed linear smooth trends, while non-Newtonian fluids showed complex rheological behavior, indicating their potential role in cryptic pregnancy detection. It had been observed that for the structures S124, S125, and S126, pressure value initially rises at point P1, which is further increased from P2 to P5 (2 × 106 Pa) within the time duration from T/3 to T/2 s. Newtonian models are useful for a simplified description, ignoring non-Newtonian effects that may result in incorrect predictions of flow behavior, which can undermine the efficiency and reliability of fluid transport processes in artificial circulation devices, microfluidic systems, and industrial processes. This research identifies the importance of rheological analysis in providing an alternative, noninvasive early detection test, which improves diagnostic accuracy and maternal health outcomes.

1 January 2024 in International Journal for Multiscale Computational Engineering
Verified
Journal Article
Closed access
PDF file
NSNitesh Kumar Singh
Nitesh Kumar Singh
Posterior lumbar interbody fusion (PLIF) is a common technique for decompressing the diseased spinal segment. This study aims to compare the biomechanical effects of four PLIF scenarios. A finite element model of the L3-L4 segment is used to simulate decompression with different scenarios: S1 (PEEK cage), S2 (PEEK cage with graft), S3 (Titanium cage), and S4 (Titanium cage with graft). Range of motion, stress, and micromotion are measured under various loading conditions. S2 demonstrates sufficient stability, reduced micromotion, and lower stress on the adjacent parts of the lumbar segment, indicating that S2 may be a preferred option for PLIF.