Gyroid (G) and primitive (P) porous structures have multiple application areas, ranging from thermal to mechanical, and fall in the complex triply periodic minimal surface (TPMS) category. Such intricate bioinspired constructs are gaining attention because they meet both biological and mechanical requirements for osseous reconstruction. The study aimed to develop G and P structures with varying porosity levels from 40% to 80% by modulating the strut thickness to proportionally resemble the stiffness of host tissue. The performance characteristics were evaluated using Ti6Al4V and important relationships between feature dimension, strut thickness, porosity, and stiffness were established. Numerical results showed that the studied porous structures could decrease stiffness from 107 GPa (stiffness of Ti6Al4V) to the range between 4.21 GPa to 29.63 GPa of varying porosities, which matches the human bone stiffness range. Furthermore, using this foundation, a subject-specific scaffold (made of P unit cells with an 80% porosity) was developed to reconstruct segmental bone defect (SBD) of the human femur, demonstrating a significant decrease in the stress shielding effect. Stress transfer on the bone surrounded by a P scaffold was compared with a solid implant which showed a net increase of stress transfer of 76% with the use of P scaffold. In the conclusion, future concerns and recommendations are suggested.
(1) Background: Intervertebral disc degeneration has been linked to obesity; its potential mechanical effects on the intervertebral disc remain unknown. This study aimed to develop and validate a patient-specific model of L3–L4 vertebrae and then use the model to estimate the impact of increasing body weight on disc degeneration. (2) Methods: A three-dimensional model of the functional spinal unit of L3–L4 vertebrae and its components were developed and validated. Validation was achieved by comparing the range of motions (RoM) and intradiscal pressures with the previous literature. Subsequently, the validated model was loaded according to the body mass index and estimated stress, deformation, and RoM to assess disc degeneration. (3) Results: During validation, L3–L4 RoM and intradiscal pressures: flexion 5.17° and 1.04 MPa, extension 1.54° and 0.22 MPa, lateral bending 3.36° and 0.54 MPa, axial rotation 1.14° and 0.52 MPa, respectively. When investigating the impact of weight on disc degeneration, escalating from normal weight to obesity reveals an increased RoM, by 3.44% during flexion, 22.7% during extension, 29.71% during lateral bending, and 33.2% during axial rotation, respectively. Also, stress and disc deformation elevated with increasing weight across all RoM. (4) Conclusions: The predicted mechanical responses of the developed model closely matched the validation dataset. The validated model predicts disc degeneration under increased weight and could lay the foundation for future recommendations aimed at identifying predictors of lower back pain due to disc degeneration.