Microgrids (MGs) are systems that cleanly, efficiently, and economically integrate Renewable Energy Sources (RESs) and Energy Storage Systems (ESSs) to the electrical grid. They are capable of reducing transmission losses and improving the use of electricity and heat. However, RESs presents intermittent behavior derived from the stochastic nature of the renewable resources available on site. This can cause power-quality issues throughout the electrical grid, which can be solved by different optimization techniques and/or control strategies applied to power converters. This paper offers a detailed review of the literature regarding three important aspects: (i) Power-quality issues generated in MGs both in islanded mode and grid-connected mode; (ii) Optimization techniques used in the MGs to achieve the optimal operating conditions of the Energy Management System (EMS); and (iii) Control strategies implemented in the MGs to guarantee stability, mitigation of power-quality issues, power balance, and synchronization with the grid. It is worth mentioning that in this paper, we emphasize hybrid MGs (HMGs) since they combine the benefits of AC–MGs and DC–MGs while increasing system reliability. As the utility grid moves toward an optimal design of MG structures, this paper will serve as a foundation for future research, comparative analysis, and further development of novel techniques regarding HMGs.
This study examines the impact of increasing photovoltaic (PV) penetration on the transient stability of the IEEE 9-bus power system. Synchronous machines are modeled with standard subtransient dynamics, while PV units are represented as current-limited grid-following inverters. Transient stability is assessed through the Critical Clearing Time (CCT) and the post-fault dynamic behavior, obtained from time-domain simulations carried out in MATLAB/Simulink®. A permanent three-phase fault on line 7–5 is considered as the limiting contingency. The results show an increase in CCT as PV generation progressively replaces the active power supplied by synchronous machines, whose inertia is therefore maintained: from 210 ms (0% PV) to 440 ms (25%) / 1080 ms (40%) at bus 5, 410 ms (25%) / 1130 ms (40%) and 290 ms (25%) / 650 ms (40%) at buses 6 and 8, respectively, demonstrating that the injection site is a key factor for system stability. For distributed injection among the three buses, CCT values of 340 ms (25%) and 1020 ms (40%) highlight the significant influence of PV placement at bus 8. Although an overall increase in CCT was observed, higher PV penetration also led to more pronounced oscillations and operability issues after the fault. These results underscore the need for stability-oriented control strategies, such as grid-forming operation, fast active power support, and dynamic voltage control. They also suggest that planning practices should favor interconnections electrically closer to the slack generator. Overall, a high PV penetration level—modifying only the operating point of synchronous machines—allows longer fault durations to be tolerated; however, appropriate siting of PV units and the adoption of advanced inverter controls could mitigate the observed oscillations and post-fault operability challenges.