Xavier Martínez-Lladó

Dr. Xavier Martínez-Lladó


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2020 in Membranes
Verified
Journal Article
Open access
PDF file
Gaetan BlandinGaetan Blandin
Gaetan Blandin
FFFederico Ferrari
Federico Ferrari
Geoffroy LesageGeoffroy Lesage
Geoffroy Lesage
Pierre LeClechPierre LeClech
Pierre LeClech
MHMarc Heran
Marc Heran
XMXavier Martínez-Lladó
Xavier Martínez-Lladó
In the past few years, osmotic membrane systems, such as forward osmosis (FO), have gained popularity as “soft” concentration processes. FO has unique properties by combining high rejection rate and low fouling propensity and can be operated without significant pressure or temperature gradient, and therefore can be considered as a potential candidate for a broad range of concentration applications where current technologies still suffer from critical limitations. This review extensively compiles and critically assesses recent considerations of FO as a concentration process for applications, including food and beverages, organics value added compounds, water reuse and nutrients recovery, treatment of waste streams and brine management. Specific requirements for the concentration process regarding the evaluation of concentration factor, modules and design and process operation, draw selection and fouling aspects are also described. Encouraging potential is demonstrated to concentrate streams more than 20-fold with high rejection rate of most compounds and preservation of added value products. For applications dealing with highly concentrated or complex streams, FO still features lower propensity to fouling compared to other membranes technologies along with good versatility and robustness. However, further assessments on lab and pilot scales are expected to better define the achievable concentration factor, rejection and effective concentration of valuable compounds and to clearly demonstrate process limitations (such as fouling or clogging) when reaching high concentration rate. Another important consideration is the draw solution selection and its recovery that should be in line with application needs (i.e., food compatible draw for food and beverage applications, high osmotic pressure for brine management, etc.) and be economically competitive.

26 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RPRamon Pérez
Ramon Pérez
Albert Martínez-TorrentsAlbert Martínez-Torrents
Albert Martínez-Torrents
MMManuel Martínez
Manuel Martínez
STSergi Grau Torrent
Sergi Grau Torrent
LVLaura Vinardell
Laura Vinardell
IJIrene Jubany
Irene Jubany
The quality of the drinking water distributed through the networks has become the main concern of most operators. This work focuses on one of the most important variables of the drinking water distribution networks (WDN) that use disinfection, chlorine. This powerful disinfectant must be dosed carefully in order to reduce disinfection byproducts (DBPs). The literature demonstrates researchers’ interest in modelling chlorine decay and using several different approaches. Nevertheless, the full-scale application of these models is far from being a reality in the supervision of water distribution networks. This paper combines the use of validated chlorine prediction models with an intensive study of a large amount of data and its influence on the model’s parameters. These parameters are estimated and validated using data coming from the Supervisory Control and Data Acquisition (SCADA) software, a full-scale water distribution system, and using off-line analytics. The result is a powerful methodology for calibrating a chlorine decay model on-line which coherently evolves over time along with the significant variables that influence it.

20 April 2021 in Water
Verified
Journal Article
Open access
PDF file
ACAnna Serra Clusellas
Anna Serra Clusellas
LSluca sbardella
luca sbardella
PHPol Herrero
Pol Herrero
APAntoni Del Pino
Antoni Del Pino
Marc RiuMarc Riu
Marc Riu
XMXavier Martínez-Lladó
Xavier Martínez-Lladó
Electro-Fenton (EF) and peroxyelectrocoagulation (PEC) processes were investigated to mineralize 10 mg L−1 erythromycin from ultrapure water, evaluating the influence of the anode material (BDD and Fe), current density (janode) (5 mA cm−2 and 10 mA cm−2), oxygen flowrate injected to the cathode (0.8 L min−1 O2 and 2.0 L min−1 O2) and pH (2.8, 5.0 and 7.0) on the process efficiency and the electricity costs. 70% mineralization was reached after applying 0.32 A h L−1 under the best operational conditions: PEC treatment at 5 mA cm−2, 2.0 L min−1 O2 and pH 2.8. The electricity consumption of the electrochemical cell under these conditions was approximately 0.3 kWh m−3. Early-stage intermediates produced from erythromycin degradation were identified and quantified throughout the treatment and a potential erythromycin degradation pathway was proposed. The most appropriate operational conditions tested with synthetic solutions were applied to treat a real effluent from the tertiary treatment of an urban wastewater treatment plant. All emerging compounds listed in the EU Decision 2018/840 (Watch List 2018) were determined before and after the PEC treatment. All listed pollutants were degraded below their quantification limit, except estrone and 17-α-ethinylestradiol which were 99% removed from water. Electricity consumption of the electrochemical cell was 0.4 kWh m−3. Whilst awaiting future results that demonstrate the innocuity of the generated byproducts, the results of this investigation (high removal yields for emerging pollutants together with the low electricity consumption of the cell) indicate the promising high potential of PEC treatment as a water treatment/remediation/regeneration technology.

21 December 2023 in Water
Verified
Journal Article
Open access
PDF file
LFLidia Fernandez-Rojo
Lidia Fernandez-Rojo
VMVicenç Martí
Vicenç Martí
IJIrene Jubany
Irene Jubany
NBNeus Bahí
Neus Bahí
MJMarcel Janer
Marcel Janer
MRMiquel Rovira
Miquel Rovira
The employment of granular ferric iron-(oxy)hydroxides, a well-known economic and effective method, lowers arsenic concentrations in different water types. However, for direct application in polluted groundwaters, there is a need to develop new injectable adsorbents for aquifers that could also neutralize acidic media. In this context, a granular ferric hydroxide-calcite (GFH-C) adsorbent was size-reduced to 0.4–50 µm by sonication with the aim of improving (i) the adsorption of As(III) and As(V) at different pHs and (ii) the pH control through the dissolution of calcite. Batch experiments were conducted to determine As(III) and As(V) adsorption isotherms and kinetics, as well as calcite dissolution kinetics, using GFH-C of two sizes (granular and sonicated). Results showed that the arsenic binding capacity of sonicated adsorbents did not improve significantly. On the contrary, the As(III) and As(V) adsorption kinetics improved with the sonication, as in the case of calcite dissolution kinetics. The dissolution of calcite from the adsorbent made the water pH increase to around 9.2–9.4. The sonicated adsorbent offers an advantage in depolluting As-containing groundwater due to its smaller size, which is linked with faster arsenic adsorption and effective acidic water neutralization.

26 April 2024 in Water
Verified
Journal Article
Open access
PDF file
ACAlicia Cano-López
Alicia Cano-López
LFLidia Fernandez-Rojo
Lidia Fernandez-Rojo
Leónidas Pérez EstradaLeónidas Pérez Estrada
Leónidas Pérez Estrada
SJSònia Jou-Claus
Sònia Jou-Claus
MBMarta Batriu
Marta Batriu
VMVíctor Matamoros
Víctor Matamoros
Industrial chlorinated solvents continue to be among the most significant issues in groundwater (GW) pollution worldwide. This study assesses the effectiveness of eight novel oxidation treatments, including persulfate (PS), ferrous sulfate, sulfidated nano-zero valent iron (S-nZVI), and potassium ferrate, along with their combinations, for the potential in situ remediation of GW polluted with chlorinated solvents (1,2-dichloroethylene, trichloroethylene, and tetrachloroethylene). Our bench-scale results reveal that the combined addition of PS and S-nZVI can effectively eliminate trichloroethylene (10 µg/L), achieving removal rates of up to 80% and 92% within 1 h, respectively, when using synthetic GW. In the case of real GW, this combination achieved removal rates of 69, 99, and 92% for cis-1,2-dichloroethylene, trichloroethylene, and tetrachloroethylene, respectively, within 24 h. Therefore, this proposed remediation solution resulted in a significant reduction in the environmental risk quotient, shifting it from a high-risk (1.1) to a low-risk (0.2) scenario. Furthermore, the absence of transformation products, such as vinyl chloride, suggests the suitability of employing this solution for the in situ remediation of GW polluted with chlorinated solvents.