Michał Wąsowicz

Dr. Michał Wąsowicz

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2017 in Materials
Verified
Journal Article
Open access
PDF file
MWMichał Wąsowicz
Michał Wąsowicz
Mateusz FicekMateusz Ficek
Mateusz Ficek
MWMaciej Wrobel
Maciej Wrobel
RCRuchira Chakraborty
Ruchira Chakraborty
Dror FixlerDror Fixler
Dror Fixler
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
This study reports the interactions of modified nanodiamond particles in vitro with human blood. Modifications performed on the nanodiamond particles include oxygenation with a chemical method and hydrogenation upon chemical vapor deposition (CVD) plasma treatment. Such nanodiamonds were later incubated in whole human blood for different time intervals, ranging from 5 min to 5 h. The morphology of red blood cells was assessed along with spectral measurements and determination of haemolysis. The results showed that no more than 3% of cells were affected by the nanodiamonds. Specific modifications of the nanodiamonds give us the possibility to obtain nanoparticles which are biocompatible with human blood. They can form a basis for the development of nanoscale biomarkers and parts of sensing systems and devices useful in biomedical environments.

11 January 2018 in Materials
Verified
Journal Article
Open access
PDF file
DMDaria Majchrowicz
Daria Majchrowicz
MKMonika Kosowska
Monika Kosowska
SJSankaran K. J.
Sankaran K. J.
PSPrzemyslaw Struk
Przemyslaw Struk
MWMichał Wąsowicz
Michał Wąsowicz
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska
In this work we present the fabrication and characterization of a diamond film which can be utilized in the construction of optical sensors for the investigation of biological samples. We produced a nitrogen-doped diamond (NDD) film using a microwave plasma enhanced chemical vapor deposition (MWPECVD) system. The NDD film was investigated with the use of scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman spectroscopy. The NDD film was used in the construction of the fiber optic sensor. This sensor is based on the Fabry–Pérot interferometer working in a reflective mode and the NDD film is utilized as a reflective layer of this interferometer. Application of the NDD film allowed us to obtain the sensor of hemoglobin concentration with linear work characteristics with a correlation coefficient (R2) equal to 0.988.

7 December 2017
Verified
Conference Paper
Closed access
MWMichał Wąsowicz
Michał Wąsowicz
MGMichał Grochowski
Michał Grochowski
MKMarek Kulka
Marek Kulka
AMAgnieszka Mikołajczyk
Agnieszka Mikołajczyk
Mateusz FicekMateusz Ficek
Mateusz Ficek
MCMaciej Cićkiewicz
Maciej Cićkiewicz

29 October 2018 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
MMMarcin Marzejon
Marcin Marzejon
MKMonika Kosowska
Monika Kosowska
DMDaria Majchrowicz
Daria Majchrowicz
BBBarbara Bullo-Piontecka
Barbara Bullo-Piontecka
MWMichał Wąsowicz
Michał Wąsowicz
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska

19 April 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PLPaulina Listewnik
Paulina Listewnik
MWMichał Wąsowicz
Michał Wąsowicz
MKMonika Kosowska
Monika Kosowska
AMAdam Mazikowski
Adam Mazikowski
This paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various diseases in veterinary medicine, including 635 nm (red), 532 nm (green) and 447 nm (blue). The obtained results are consistent with data provided in reference sources and can also be approximated for the entire spectral range of visible radiation (380–780 nm). The developed system is suitable for further measurements of phantoms, which can be adapted to imitate different tissues.

26 September 2016
Verified
Conference Paper
Closed access
PDF file
DMDaria Majchrowicz
Daria Majchrowicz
Mateusz FicekMateusz Ficek
Mateusz Ficek
TBT. Baran
T. Baran
MWMichał Wąsowicz
Michał Wąsowicz
PSPrzemyslaw Struk
Przemyslaw Struk
Małgorzata SzczerskaMałgorzata Szczerska
Małgorzata Szczerska