Overdose of atropine usually leads to heart failure and death and has long been used as a method of murder. We propose a simple electrochemical approach for atropine sensing using an electrode modified with nafion/polycarboxylate functionalized graphene nanoflakes (Nf/p-GNF/E). The polycarboxylate functionalized graphene nanoflakes were characterized by SEM, FT-IR, and electrochemical techniques. The electrochemical behavior and determination of atropine at the Nf/p-GNF/E were examined using cyclic voltammetry (CV) and adsorptive anodic stripping voltammetry (AdASV). The amount of Nf/p-GNF drop-cast on the electrode, accumulation potential and time, and pH buffer were optimized. Under the optimized conditions, the modified electrode showed excellent electrochemical oxidation of atropine with a linear range from 6.0 × 10 −6 to 1.0 × 10 −4 mol L −1 and a detection limit of 1.9 × 10 −6 mol L −1 . The proposed sensor exhibited excellent repeatability (RSD < 2.8%), reproducibility (RSD < 2.7%), and good resistance to interference from glucose, fructose, dopamine, uric acid, and ascorbic acid. The sensor was applied to determine atropine in urine samples and the results were in good agreement with results from the spectrophotometric analysis.
An electrochemical sensor was developed based on a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs) for the determination of promethazine (PMZ) in ‘purple drank’, pharmaceutical formulations, and synthetic saliva. The oxidation of PMZ at the modified electrode occurred at a higher cathodic potential and produced a higher sensitivity compared to the unmodified GCE. The morphology of the modified electrode was characterized using field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS), and transmission electron microscopy (TEM). The presence of MWCNTs and AuNPs was confirmed. The optimized parameters included the concentration and pH of the supporting electrolyte, amount of modifiers used to fabricate the electrode, deposition potential, and time. Using these optimized conditions, the method has a linear range from 0.5 to 100 μmol L−1, with a R2 value of 0.9991. The limit of detection (3SDblank/slope) was 0.13 μmol L−1. The proposed electrochemical sensor was successfully applied for the determination of PMZ in ‘purple drank’, pharmaceutical formulations, and spiked synthetic saliva samples. The results obtained from this sensor were in statistical agreement with the values obtained using the reference gas chromatography-flame ionization method.
Lean cocktail is an improvised drink that contains prescription drugs. It is prepared and abused primarily by young people and may cause serious long-term and short-term health problems. This study sought to develop a method of simultaneously determining the commonly abused prescription drugs in lean cocktail. To achieve this objective, gas chromatography with flame ionization detection (GC-FID) was employed with a dilute-and-shoot sample preparation technique. The chromatographic method was optimized and fully validated, and all analytes were well separated within 19 min. The responses were linear across the concentration range from 2.5 to 1000 µg mL−1 (r2 > 0.99), and the limits of detection and quantitation were 1.25 to 2.50 µg mL−1 and 2.5 to 55.0 µg mL−1, respectively. The accuracy and precision were from 91% to 110% and 4.1% to 8.7% relative standard deviation, respectively. The sample dilution from 2- to 10-fold and the matrix had no effect upon the analysis. Robustness testing revealed that the method is reliable. The developed method has identified tramadol and promethazine as the typically abused prescription drugs in the analyzed lean cocktail samples. These findings indicate that this new method is simple and reliable and has potential benefits for the forensic analysis of lean cocktail samples.
A novel foam-based colorimetric alcohol sensor was developed for the detection of alcohol in saliva. Detection was based on the color change of a potassium dichromate-sulfuric acid solution absorbed by melamine foam. In the presence of alcohol, the orange colorimetric sensor changed color to brown, green and, ultimately, blue, depending on the concentration of alcohol in the sample. The response of the proposed sensor toward alcohol was linear from 0.10 to 2.5% v/v. The limit of detection was 0.03% v/v. Alcohol concentration could be determined using the naked eye in the range of 0.00 to 10% v/v. The developed alcohol sensor presented good operational accuracy (RSD = 0.30–1.90%, n = 8) and good stability for 21 days when stored at 25 °C and 75 days when stored at 4 °C. The results of alcohol detection with the developed sensor showed no significant difference from the results of spectrophotometric detection at a 95% confidence level (p > 0.05). The sensor was easy to use, small, inexpensive and portable, enabling drivers to accurately measure their own blood alcohol level and providing convenient speed in forensic applications.