Artificial intelligence is gaining increasing relevance in the field of radiology. This study retrospectively evaluates how a commercially available deep learning algorithm can detect pneumonia in chest radiographs (CR) in emergency departments. The chest radiographs of 948 patients with dyspnea between 3 February and 8 May 2020, as well as 15 October and 15 December 2020, were used. A deep learning algorithm was used to identify opacifications associated with pneumonia, and the performance was evaluated by using ROC analysis, sensitivity, specificity, PPV and NPV. Two radiologists assessed all enrolled images for pulmonal infection patterns as the reference standard. If consolidations or opacifications were present, the radiologists classified the pulmonal findings regarding a possible COVID-19 infection because of the ongoing pandemic. The AUROC value of the deep learning algorithm reached 0.923 when detecting pneumonia in chest radiographs with a sensitivity of 95.4%, specificity of 66.0%, PPV of 80.2% and NPV of 90.8%. The detection of COVID-19 pneumonia in CR by radiologists was achieved with a sensitivity of 50.6% and a specificity of 73%. The deep learning algorithm proved to be an excellent tool for detecting pneumonia in chest radiographs. Thus, the assessment of suspicious chest radiographs can be purposefully supported, shortening the turnaround time for reporting relevant findings and aiding early triage.
In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise–compared to a standard EID-CT–and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.
In the early diagnostic workup of acute pancreatitis (AP), the role of contrast-enhanced CT is to establish the diagnosis in uncertain cases, assess severity, and detect potential complications like necrosis, fluid collections, bleeding or portal vein thrombosis. The value of texture analysis/radiomics of medical images has rapidly increased during the past decade, and the main focus has been on oncological imaging and tumor classification. Previous studies assessed the value of radiomics for differentiating between malignancies and inflammatory diseases of the pancreas as well as for prediction of AP severity. The aim of our study was to evaluate an automatic machine learning model for AP detection using radiomics analysis. Patients with abdominal pain and contrast-enhanced CT of the abdomen in an emergency setting were retrospectively included in this single-center study. The pancreas was automatically segmented using TotalSegmentator and radiomics features were extracted using PyRadiomics. We performed unsupervised hierarchical clustering and applied the random-forest based Boruta model to select the most important radiomics features. Important features and lipase levels were included in a logistic regression model with AP as the dependent variable. The model was established in a training cohort using fivefold cross-validation and applied to the test cohort (80/20 split). From a total of 1012 patients, 137 patients with AP and 138 patients without AP were included in the final study cohort. Feature selection confirmed 28 important features (mainly shape and first-order features) for the differentiation between AP and controls. The logistic regression model showed excellent diagnostic accuracy of radiomics features for the detection of AP, with an area under the curve (AUC) of 0.932. Using lipase levels only, an AUC of 0.946 was observed. Using both radiomics features and lipase levels, we showed an excellent AUC of 0.933 for the detection of AP. Automated segmentation of the pancreas and consecutive radiomics analysis almost achieved the high diagnostic accuracy of lipase levels, a well-established predictor of AP, and might be considered an additional diagnostic tool in unclear cases. This study provides scientific evidence that automated image analysis of the pancreas achieves comparable diagnostic accuracy to lipase levels and might therefore be used in the future in the rapidly growing era of AI-based image analysis.
24 May 2024 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
The introduction of photon-counting detector CT (PCD-CT) marks a remarkable leap in innovation in CT imaging. The new detector technology allows X-rays to be converted directly into an electrical signal without an intermediate step via a scintillation layer and allows the energy of individual photons to be measured. Initial data show high spatial resolution, complete elimination of electronic noise, and steady availability of spectral image data sets. In particular, the new technology shows promise with respect to the imaging of osseous structures. Recently, PCD-CT was implemented in the clinical routine. The aim of this review was to summarize recent studies and to show our first experiences with photon-counting detector technology in the field of musculoskeletal radiology.We performed a literature search using Medline and included a total of 90 articles and reviews that covered recent experimental and clinical experiences with the new technology.In this review, we focus on (1) spatial resolution and delineation of fine anatomic structures, (2) reduction of radiation dose, (3) electronic noise, (4) techniques for metal artifact reduction, and (5) possibilities of spectral imaging. This article provides insight into our first experiences with photon-counting detector technology and shows results and images from experimental and clinical studies.Bette S, Risch F, Becker J et al. Photon-counting detector CT – first experiences in the field of musculoskeletal radiology. Fortschr Röntgenstr 2024; DOI 10.1055/a-2312-6914
In photon-counting detector CT (PCD-CT), coronary artery calcium scoring (CACS) can be performed using virtual non-contrast (VNC) series derived from coronary CT angiography (CCTA) datasets. Our study analyzed image characteristics of VNC series in terms of the efficacy of virtual iodine “removal” and image noise to determine whether the prerequisites for calcium quantification were satisfied. We analyzed 38 patients who had undergone non-enhanced CT followed by CCTA on a PCD-CT. VNC reconstructions were performed at different settings and algorithms (conventional VNCConv; PureCalcium VNCPC). Virtual iodine “removal” was investigated by comparing histograms of heart volumes. Noise was assessed within the left ventricular cavity. Calcium was quantified on the true non-contrast (TNC) and all VNC series. The histograms were comparable for TNC and all VNC. Image noise between TNC and all VNC differed slightly but significantly. VNCConv CACS showed a significant underestimation regardless of the reconstruction setting, while VNCPC CACS were comparable to TNC. Correlations between TNC and VNC were excellent, with a higher predictive accuracy for VNCPC. In conclusion, the iodine contrast can be effectively subtracted from CCTA datasets. The remaining VNC series satisfy the requirements for CACS, yielding results with excellent correlation compared to TNC-based CACS and high predicting accuracy.