Stefanie Bette

Dr. Stefanie Bette


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
JDJosua A. Decker
Josua A. Decker
SBStefanie Bette
Stefanie Bette
NLNora Lubina
Nora Lubina
KRKatharina Rippel
Katharina Rippel
FBFranziska M. Braun
Franziska M. Braun
FSFlorian Schwarz
Florian Schwarz

14 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SBStefanie Bette
Stefanie Bette
JDJosua A. Decker
Josua A. Decker
FBFranziska M. Braun
Franziska M. Braun
JBJudith Becker
Judith Becker
MHMark Haerting
Mark Haerting
FSFlorian Schwarz
Florian Schwarz
In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise–compared to a standard EID-CT–and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.

22 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
JDJosua A. Decker
Josua A. Decker
SBStefanie Bette
Stefanie Bette
CSChristian Scheurig-Muenkler
Christian Scheurig-Muenkler
BJBertram Jehs
Bertram Jehs
FRFranka Risch
Franka Risch
FSFlorian Schwarz
Florian Schwarz
The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNCPC) vs. the standard algorithm (VNCConv) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNCConv- and VNCPC-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNCConv-, VNCPC-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNCPC- than VNCConv-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNCConv-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNCPC-reconstructions. Readers considered 95% of VNCPC-series fully or mostly suited to replace TNC-series; for VNCConv-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNCPC-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases.

10 October 2020 in Neurosurgical Review
Verified
Journal Article
Open access
PDF file
Vicki ButenschoenVicki Butenschoen
Vicki Butenschoen
NSNina Schwendinger
Nina Schwendinger
AWAlexander von Werder
Alexander von Werder
SBStefanie Bette
Stefanie Bette
MWMaximilian Wienke
Maximilian Wienke
JGJens Gempt
Jens Gempt
Transsphenoidal surgery (TSS) represents the gold standard of pituitary adenoma resection, providing a safe and minimal invasive treatment for patients suffering from symptoms of mass effect. The aim of this study is to analyze the postoperative improvement of visual function after adenoma resection and to identify prognostic factors for the postoperative clinical recovery. We performed a retrospective analysis of all consecutive patients treated via a transsphenoidal approach for pituitary adenomas from April 2006 to December 2019 in a high-volume neurosurgical department. Our primary outcome was postoperative visual acuity and visual field impairment; the clinical findings were followed up to 3 months after surgery and correlated with clinical and radiographic findings. In total, 440 surgeries were performed in our department for tumors of the sella region in a time period of 13 years via transsphenoidal approach, and 191 patients included in the analysis. Mean age was 55 years, and 98% were macroadenomas. Mean preoperative visual acuity in patients with preoperative impairment (n = 133) improved significantly from 0.64/0.65 to 0.72/0.75 and 0.76/0.8 (right eye R/left eye L) postoperatively and at 3 months follow-up (p < 0.001). Visual acuity significantly depended on Knosp classification but not Hardy grading. The strongest predictor for visual function recovery was age. Transsphenoidal pituitary tumor resection remains a safe and effective treatment in patients with preoperative visual impairment. It significantly improves visual acuity and field defects after surgery, and recovery continues at the 3 months follow-up examination.

20 June 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
DPDaniel Popp
Daniel Popp
ASAndrea X. Sinzinger
Andrea X. Sinzinger
JDJosua A. Decker
Josua A. Decker
FBFranziska M. Braun
Franziska M. Braun
SBStefanie Bette
Stefanie Bette
FSFlorian Schwarz
Florian Schwarz

20 September 2021 in Neurosurgical Review
Verified
Journal Article
Open access
PDF file
Vicki ButenschoenVicki Butenschoen
Vicki Butenschoen
AWAlexander von Werder
Alexander von Werder
SBStefanie Bette
Stefanie Bette
VSVeronika Schmette
Veronika Schmette
NSNina Schwendinger
Nina Schwendinger
JGJens Gempt
Jens Gempt
Transsphenoidal surgery provides a minimal invasive treatment for pituitary adenoma. Our aim is to evaluate the endocrinological outcomes after adenoma resection focusing on the corticotroph function, and to identify prognostic factors for an impaired hypothalamic–pituitary–adrenal-axis function (HPA) and the reliability of postoperative early morning serum cortisol measurements. We performed a retrospective analysis of all patients treated for pituitary adenoma from April 2006 to January 2019 in our neurosurgical department. Pituitary function was assessed pre- and postoperatively as well as at 6 weeks to 12 weeks and at 1-year follow-up. Two hundred eleven patients were included. Nine percent of the patients recovered from a preoperative adrenal insufficiency, 10.4% developed a new need for hormone substitution, and a long-term deficiency of the hypothalamic–pituitary–adrenal-axis was observed in 30.9%. Cortisol measurements 5 days after surgery had a lower area under the curve (AUC) than cortisol levels detected after 6 to 12 weeks (AUC 0.740 vs. AUC 0.808) in predicting an intact corticotrope function. The cut-off value determined for cortisol measured after 6 weeks was 6.95 µg/dl (sensitivity of 94%, specificity of 68%). Postoperative early morning cortisol levels seem to be less sensitive and specific in predicting long-term corticotroph function than measurements after 6 weeks and 1 year, emphasizing the importance of endocrine follow-up testing.