Franka Risch

Ms. Franka Risch


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
JDJosua A. Decker
Josua A. Decker
SBStefanie Bette
Stefanie Bette
NLNora Lubina
Nora Lubina
KRKatharina Rippel
Katharina Rippel
FBFranziska M. Braun
Franziska M. Braun
FSFlorian Schwarz
Florian Schwarz

14 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SBStefanie Bette
Stefanie Bette
JDJosua A. Decker
Josua A. Decker
FBFranziska M. Braun
Franziska M. Braun
JBJudith Becker
Judith Becker
MHMark Haerting
Mark Haerting
FSFlorian Schwarz
Florian Schwarz
In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise–compared to a standard EID-CT–and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.

22 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
JDJosua A. Decker
Josua A. Decker
SBStefanie Bette
Stefanie Bette
CSChristian Scheurig-Muenkler
Christian Scheurig-Muenkler
BJBertram Jehs
Bertram Jehs
FRFranka Risch
Franka Risch
FSFlorian Schwarz
Florian Schwarz
The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNCPC) vs. the standard algorithm (VNCConv) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNCConv- and VNCPC-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNCConv-, VNCPC-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNCPC- than VNCConv-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNCConv-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNCPC-reconstructions. Readers considered 95% of VNCPC-series fully or mostly suited to replace TNC-series; for VNCConv-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNCPC-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases.

20 June 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
DPDaniel Popp
Daniel Popp
ASAndrea X. Sinzinger
Andrea X. Sinzinger
JDJosua A. Decker
Josua A. Decker
FBFranziska M. Braun
Franziska M. Braun
SBStefanie Bette
Stefanie Bette
FSFlorian Schwarz
Florian Schwarz

4 January 2024 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
FRFranka Risch
Franka Risch
EHEva Harmel
Eva Harmel
KRKatharina Rippel
Katharina Rippel
BWBastian Wein
Bastian Wein
PRPhilip Raake
Philip Raake
JDJosua A. Decker
Josua A. Decker
The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.

28 December 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
FRFranka Risch
Franka Risch
ABAnsgar Berlis
Ansgar Berlis
TKThomas Kroencke
Thomas Kroencke
FSFlorian Schwarz
Florian Schwarz
CMChristoph J. Maurer
Christoph J. Maurer
SUMMARY: In this anthropomorphic head phantom study, samples containing blood and contrast agent with concentrations ranging from 0 to 6 mg iodine per milliliter and another set of samples without blood for reference were scanned with a photon-counting detector CT using a standard cranial protocol. It was demonstrated that photon-counting detector CT can reliably distinguish hemorrhage and contrast media, including density determination of the latter. The technology promises to add value in several neuroimaging applications.