Since their advent in daily clinical practice, continuous subcutaneous insulin infusion (CSII) systems have been increasingly improved, leading to a high percentage of both adult and pediatric patients with diabetes now using insulin pumps. Different types of CSII systems are currently available, which are characterized by different settings and technical features. This longitudinal observational study aims to evaluate real-word glycemic outcomes in children and adolescents with type 1 diabetes using three different CSII devices: hybrid closed-loop (HCL) systems, predictive low glucose (PLGS) systems, and non-automated insulin pumps. The secondary objective was to identify clinical variables that may significantly influence the achievement of therapeutic goals in our study cohort. One-hundred-and-one patients on CSII therapy attending our pediatric diabetes center were enrolled. When compared with the non-automated group, patients using HCL systems showed higher levels of time in target glucose range (p = 0.003) and lower glucose variability (p = 0.008). Similarly, we found significantly better glucose metrics in HCL users in comparison to PLGS patients (time in range p = 0.008; coefficient of variation p = 0.009; time above 250 mg/dL p = 0.007). Multiple linear regression models showed that HCL systems (time in range p < 0.001) and high daily percentage of glycemic sensor use (time in range p = 0.031) are predictors for good glycemic control. The introduction and increasing availability of novel technologies for diabetes represent a promising strategy to improve glycemic control and quality of life in pediatric patients with type 1 diabetes. Our real-world data confirm the superiority of HCL systems in terms of improvement of time spent in the target glucose range, prevention of hypoglycemia, and reduction of glycemic variability.
This retrospective study aimed to describe, firstly, characteristics and outcomes of the intraoperative neural monitoring technology in the pediatric population, and secondarily the recurrent laryngeal nerve complication rate. Thirty-seven patients (age <18 years) operated on from 2015 to 2021 by conventional open thyroid surgery were included. Twenty-four (64.9%) total thyroidectomies and 13 (35.1%) lobectomies were performed. Seven central and six lateral lymph node dissections completed 13 bilateral procedures. Histology showed malignancy in 45.9% of the cases. The differences between the electromyographic profiles of endotracheal tubes or electrodes for continuous monitoring were not statistically significant. In our series of young patients, both adhesive (even in 4- or 5-year-olds) and embedded endotracheal tubes were used, while in patients 3 years old or younger, the use of a more invasive detection method with transcartilage placement recording electrodes was required. Overall, out of 61 total at-risk nerves, 5 (8.2%) recurrent laryngeal nerves were injured with consequent intraoperative loss of the signal; however, all these lesions were transient, restoring their normal functionality within 4 months from surgical procedure. To our knowledge, this is the first study of intraoperative neural monitoring management in a cohort of Italian pediatric patients.