This paper presents the results of a field study undertaken all over the Punjab, Pakistan, to evaluate the socio-economic and climatic impact of photovoltaic-operated high-efficiency irrigation systems (HEIS), i.e., drip and sprinkler irrigation systems. Nearly half of the rural population relies on agriculture for a living, and the recent energy crisis has had a negative impact on rural communities. Farmers’ reliance on fossil fuels for the operation of irrigation systems has increased exponentially, resulting in the high costs of agricultural production. Primary data regarding on-farm agriculture and irrigation practices used in this study were collected through an intensive on-farm survey, while secondary data were taken from published reports and statistics. The results of the current investigation show that the installation of PV systems has resulted in the increased adoption of high-efficiency irrigation systems, a reduction in the high operational costs incurred on account of old diesel-powered pumping systems (with an annual saving of 6.6 million liters of diesel), a 100% increase in farmer’s income, a reduction of 17,622 tons of CO2 emissions per annum, and 41% savings in water. The unit cost of PV-powered HEIS was found to be 0.1219 USD/kWh, which was 4% and 66% less than subsidized electricity cost and diesel cost, respectively.
This paper presents the optimal design of a photovoltaic (PV) drip irrigation system. Designing a PV system is based on calculated motor power, solar irradiance level and other meteorological parameters at a certain geographical location. Therefore, a simulation study of the designed PV system were performed by a PVGIS simulation tool. The PVGIS simulation tool analyzes the potential of power generation with optimal PV modules tilt angle and orientation on a monthly and annual basis, and an analysis of the overall shading situation (horizon) as well as the internal shading between the PV module rows. The selection of water pump and motor depends upon the depth of water table and desired discharge and head to operate the irrigation system. Furthermore, a locally developed Solar-Drip Simulation Tool (SoSiT) was used for load and supply optimization. Based on ambient temperature, solar irradiation and water requirements, SoSiT calculates net generation by a PV system and resultant water output of the irrigation system. The particular drip irrigation site has two zones; the maximum water requirement for zone 1 (row crop) is 50,918.40 Liters/day and for zone 2 (orchards) is 56,908.80 L/day. From PVGIS simulation results, the maximum daily energy production of the designed PV system was 6.48 kWh and monthly energy production was 201 kWh in the month of May. SoSiT results showed that the PV system fulfilled the required crop requirement by only using 28% of the potential water supply, and 72% of the potential water supply from a solar-powered pump was not used. This value is high, and it is recommended to grow more or different crops to utilize the fuel-free electricity from the PV system. The unit cost of PV-powered drip irrigation is USD 0.1013/kWh, which is 4.74% and 66.26% lower than the cost of subsidized electricity and diesel, respectively.
With the depletion of traditional fossil fuels, their disastrous impact on the environment and rising costs, renewable energy sources such as photovoltaic (PV) energy are rapidly emerging as sustainable and clean sources of power generation. The performance of photovoltaic systems is based on different factors such as the type of photovoltaic modules, irradiation potential and geographic location. In this research, PVsyst simulation software is used to design and simulate a hybrid photovoltaic system used to operate energy-efficient street lightning system. The simulation is performed to analyze the monthly/annual energy generated (kWh) by the hybrid system and specific power production (kWh/KWp). Additionally, various PV system losses are also investigated. The hybrid PV system has 4 parallel strings, and each string has 13 series-connected (mono crystalline 400 W Canadian Solar) PV modules. The energy storage system consists of 16 Narada (AcmeG 12 V 200) batteries with a nominal capacity of 1600 Ah. The simulation results show that the total annual energy production and specific energy production, were calculated to be 26.68 MWh/year and 1283 kWh/kWp/year, respectively. Simulation results also show the maximum energy injected into the utility grid in the month of June (1.814 MWh) and the minimum energy injected into the utility grid in the month of January (0.848 MWh). The battery cycle state of wear is 84.8%, and the static state of wear is 91.7%. Performance ratio (PR) analysis shows that the highest performance ratio of the hybrid system was 68.2% in December, the lowest performance ratio was 62.7% in May and the annual average performance ratio of a hybrid PV system is 65.57%. After identifying the major source of energy losses, the detailed losses for the whole year were computed and shown by the loss diagrams. To evaluate the cost effectiveness of the proposed system, a simple payback period calculation was performed.
This paper presents the results of a field study conducted in the Punjab, Pakistan, to evaluate the socio-economic and climatic impact of Photovoltaic (PV) systems installed under government subsidy scheme for operating high efficiency irrigation systems (HEIS) i.e., drip and sprinkler irrigation systems. Agriculture provides livelihood to almost half of the rural population and recent energy crisis in the country has adversely affected the rural communities. Farmer’s dependence on fossil fuels has significantly increased for operating irrigation systems which has resulted in high costs of agriculture production. Government of Punjab has launched a subsidy scheme to install PV systems for operating efficient drip and sprinkler irrigation systems on cost sharing basis. Photovoltaic systems having a capacity of 17.30 megawatt, were installed to operate high efficiency irrigation systems at around twenty thousand acres under this subsidy project, that has resulted in an annual saving of 0.0066 billion liters of diesel. The average capacity of installed PV systems was 9.0 kilowatt, which matched the 7.50 horse power of installed water pumps. On average, the cost of a PV system per acre was calculated to be 0.000142 billion PKR, while the cost per kWp was calculated to be 0.000149 billion PKR. The research results show that the installation of photovoltaic systems has increased the adoption rate of high-efficiency irrigation systems, reduced carbon dioxide emissions, and reduced the high operating costs associated with diesel powered pump systems. The primary data about on-farm agriculture and irrigation practices used in this study were collected through in-depth farmer surveys, while the secondary data information came from reports, official documents and statistics issued by the government.