Water is a precious resource for agriculture and most of the land is irrigated by tube wells. Diesel engines and electricity-operated pumps are widely used to fulfill irrigation water requirements; such conventional systems are inefficient and costly. With rising concerns about global warming, it is important to choose renewable energy source. In this study, SPVWPS has been optimally designed considering the water requirement, solar resources, tilt angle and orientation, losses in both systems and performance ratio. A PVSyst and SoSiT simulation tools were used to perform simulation analysis of the designed solar photovoltaic WPS. After designing and performance analysis, farmers were interviewed during fieldwork to assess socioeconomic impacts. In the result section, performance of PV system is analyzed at various tilt angles and it is established that system installed at a 15° tilt angle is more efficient. The annual PV array virtual energy at MPP of designed photovoltaic system is 33342 kWh and the annual energy available to operate the WPS is 23502 kWh. Module array mismatch and ohmic wiring losses are 374.16 kWh and 298.83 kWh, respectively. The total annual water demand of the selected site is 80769 m³ and designed SPWPS pumped 75054 m³ of water, supplying 92.93% of the irrigation demand. The normalized values of the effective energy, system losses, collection losses and unused energy in the SPVWP system are 2.6 kW/kWp/day, 0.69 kW/kWp/day, 0.72 kW/kWp/day and 0.48 kW/kWp/day, respectively. The annual average performance ratio of the proposed system is 74.62%. The results of the interviews showed that 70% of farmers are extremely satisfied with the performance of SPVWPS and 84% of farmers indicated that they did not incur any operating costs. The unit cost of the SPWPS is 0.17 €/kWh, which is 56.41% and 19.04% less expensive than the cost of diesel and grid electricity.
With the depletion of traditional fossil fuels, their disastrous impact on the environment and rising costs, renewable energy sources such as photovoltaic (PV) energy are rapidly emerging as sustainable and clean sources of power generation. The performance of photovoltaic systems is based on different factors such as the type of photovoltaic modules, irradiation potential and geographic location. In this research, PVsyst simulation software is used to design and simulate a hybrid photovoltaic system used to operate energy-efficient street lightning system. The simulation is performed to analyze the monthly/annual energy generated (kWh) by the hybrid system and specific power production (kWh/KWp). Additionally, various PV system losses are also investigated. The hybrid PV system has 4 parallel strings, and each string has 13 series-connected (mono crystalline 400 W Canadian Solar) PV modules. The energy storage system consists of 16 Narada (AcmeG 12 V 200) batteries with a nominal capacity of 1600 Ah. The simulation results show that the total annual energy production and specific energy production, were calculated to be 26.68 MWh/year and 1283 kWh/kWp/year, respectively. Simulation results also show the maximum energy injected into the utility grid in the month of June (1.814 MWh) and the minimum energy injected into the utility grid in the month of January (0.848 MWh). The battery cycle state of wear is 84.8%, and the static state of wear is 91.7%. Performance ratio (PR) analysis shows that the highest performance ratio of the hybrid system was 68.2% in December, the lowest performance ratio was 62.7% in May and the annual average performance ratio of a hybrid PV system is 65.57%. After identifying the major source of energy losses, the detailed losses for the whole year were computed and shown by the loss diagrams. To evaluate the cost effectiveness of the proposed system, a simple payback period calculation was performed.
One of the most common sustainable energy resources that contributes a significant portion of the energy produced from renewable resources is solar photovoltaic energy. The research presented in this paper examines the behaviour of a 150.7 kWp grid-connected PV energy generation system in either feeding electrical loads to a site (a public university, GCU Faisalabad) or feeding into the utility grid when the generation from the PV system is greater than the demand from the on-site load. PVSyst 7.4 software was used in the system simulation together with Meteonorm to produce and measure climatic information sets (solar irradiance, ambient temperature, and wind speed). The analysis of the simulated energy yields included determining the optimal energy generation photovoltaic array, the energy that is fed into the utility network, normalised energy generation per installed kWp, and performance ratio. The computed annual worldwide incident energy on the collector without optical adjustments was 1764.0 kWh/m2, and the annual effective global irradiance after optical losses was 1654.7 kWh/m2. With this irradiation, the solar (PV) array produced 218.12 MWh of DC energy annually, whereas 211.70 MWh of AC energy was injected into the national grid. The designed PV system collected 0.87 kilowatt-hour/kWp/day, with system losses of 0.120 kilowatt-hour /kWp/day and 3.85 kilowatt-hour /kWp/day of produced useful energy. The measured average yearly performance ratio (PR) was 79.64%. In the month of January, the highest PR value of 85.4% was achieved.