Muhammad Tamoor

Mr. Muhammad Tamoor


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
FRFaakhar Raza
Faakhar Raza
MTMuhammad Tamoor
Muhammad Tamoor
SMSajjad Miran
Sajjad Miran
WAWaseem Arif
Waseem Arif
TKTayybah Kiren
Tayybah Kiren
Gwi Hyun LeeGwi Hyun Lee
Gwi Hyun Lee
This paper presents the results of a field study undertaken all over the Punjab, Pakistan, to evaluate the socio-economic and climatic impact of photovoltaic-operated high-efficiency irrigation systems (HEIS), i.e., drip and sprinkler irrigation systems. Nearly half of the rural population relies on agriculture for a living, and the recent energy crisis has had a negative impact on rural communities. Farmers’ reliance on fossil fuels for the operation of irrigation systems has increased exponentially, resulting in the high costs of agricultural production. Primary data regarding on-farm agriculture and irrigation practices used in this study were collected through an intensive on-farm survey, while secondary data were taken from published reports and statistics. The results of the current investigation show that the installation of PV systems has resulted in the increased adoption of high-efficiency irrigation systems, a reduction in the high operational costs incurred on account of old diesel-powered pumping systems (with an annual saving of 6.6 million liters of diesel), a 100% increase in farmer’s income, a reduction of 17,622 tons of CO2 emissions per annum, and 41% savings in water. The unit cost of PV-powered HEIS was found to be 0.1219 USD/kWh, which was 4% and 66% less than subsidized electricity cost and diesel cost, respectively.

1 April 2020 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MTMuhammad Tamoor
Muhammad Tamoor
MTM. Suleman Tahir
M. Suleman Tahir
MSMuhammad Sagir
Muhammad Sagir
MTMuhammad Bilal Tahir
Muhammad Bilal Tahir
SIShahid Iqbal
Shahid Iqbal
TNTasmia Nawaz
Tasmia Nawaz

8 May 2023 in Heliyon
Verified
Journal Article
Open access
SHSalman Habib
Salman Habib
Haoming LiuHaoming Liu
Haoming Liu
MTMuhammad Tamoor
Muhammad Tamoor
MZMuhammad Ans Zaka
Muhammad Ans Zaka
YJYouwei Jia
Youwei Jia
Salah KamelSalah Kamel
Salah Kamel
Water is a precious resource for agriculture and most of the land is irrigated by tube wells. Diesel engines and electricity-operated pumps are widely used to fulfill irrigation water requirements; such conventional systems are inefficient and costly. With rising concerns about global warming, it is important to choose renewable energy source. In this study, SPVWPS has been optimally designed considering the water requirement, solar resources, tilt angle and orientation, losses in both systems and performance ratio. A PVSyst and SoSiT simulation tools were used to perform simulation analysis of the designed solar photovoltaic WPS. After designing and performance analysis, farmers were interviewed during fieldwork to assess socioeconomic impacts. In the result section, performance of PV system is analyzed at various tilt angles and it is established that system installed at a 15° tilt angle is more efficient. The annual PV array virtual energy at MPP of designed photovoltaic system is 33342 kWh and the annual energy available to operate the WPS is 23502 kWh. Module array mismatch and ohmic wiring losses are 374.16 kWh and 298.83 kWh, respectively. The total annual water demand of the selected site is 80769 m³ and designed SPWPS pumped 75054 m³ of water, supplying 92.93% of the irrigation demand. The normalized values of the effective energy, system losses, collection losses and unused energy in the SPVWP system are 2.6 kW/kWp/day, 0.69 kW/kWp/day, 0.72 kW/kWp/day and 0.48 kW/kWp/day, respectively. The annual average performance ratio of the proposed system is 74.62%. The results of the interviews showed that 70% of farmers are extremely satisfied with the performance of SPVWPS and 84% of farmers indicated that they did not incur any operating costs. The unit cost of the SPWPS is 0.17 €/kWh, which is 56.41% and 19.04% less expensive than the cost of diesel and grid electricity.

6 January 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MTMuhammad Tamoor
Muhammad Tamoor
SHSalman Habib
Salman Habib
Abdul Rauf BhattiAbdul Rauf Bhatti
Abdul Rauf Bhatti
Arslan Dawood ButtArslan Dawood Butt
Arslan Dawood Butt
Ahmed Bilal AwanAhmed Bilal Awan
Ahmed Bilal Awan
EAEmad M. Ahmed
Emad M. Ahmed
The focus of this research is to design a ground-mounted photovoltaic system at optimal tilt angle and interrow space to meet high demand of electrical energy. The Department of Electrical Engineering and Technology, GC University Faisalabad has been considered to perform the simulation test. This study is conducted using Meteonorm software for solar resource assessment. Furthermore, HelioScope software is used for modeling of a ground-mounted photovoltaic system, study of PV system’s performance in terms of annual generation, system losses and performance ratio and analysis of photovoltaic module’s performance, current-voltage and power-voltage curves for different irradiance levels. From SLD, it is seen that 11 strings are connected to each inverter and inverters output power are combined by using 20.0 A circuit interconnects. The performance of photovoltaic systems is impacted by tilt angle and interrow spacing. From simulation results of all cases, it is concluded that the PV system installed at 15° tilt angle with 4 feet interrow spacing are more efficient than the other installed PV systems, because total collector irradiance is maximum (1725.0 kWh/m2) as compared to other tilt angles. At 15° tilt angle, the annual production of photovoltaic system is 2.265 GWh and performance ratio of PV system is 82.0%. It is envisioned that this work will provide the guidance to energy system designers, planners and investors to formulate strategies for the installation of photovoltaic energy systems in Pakistan and all over the world.

12 July 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
SMSajjad Miran
Sajjad Miran
MTMuhammad Tamoor
Muhammad Tamoor
TKTayybah Kiren
Tayybah Kiren
FRFaakhar Raza
Faakhar Raza
Muhammad Imtiaz HussainMuhammad Imtiaz Hussain
Muhammad Imtiaz Hussain
Jun-Tae KimJun-Tae Kim
Jun-Tae Kim
This paper presents the optimal design of a photovoltaic (PV) drip irrigation system. Designing a PV system is based on calculated motor power, solar irradiance level and other meteorological parameters at a certain geographical location. Therefore, a simulation study of the designed PV system were performed by a PVGIS simulation tool. The PVGIS simulation tool analyzes the potential of power generation with optimal PV modules tilt angle and orientation on a monthly and annual basis, and an analysis of the overall shading situation (horizon) as well as the internal shading between the PV module rows. The selection of water pump and motor depends upon the depth of water table and desired discharge and head to operate the irrigation system. Furthermore, a locally developed Solar-Drip Simulation Tool (SoSiT) was used for load and supply optimization. Based on ambient temperature, solar irradiation and water requirements, SoSiT calculates net generation by a PV system and resultant water output of the irrigation system. The particular drip irrigation site has two zones; the maximum water requirement for zone 1 (row crop) is 50,918.40 Liters/day and for zone 2 (orchards) is 56,908.80 L/day. From PVGIS simulation results, the maximum daily energy production of the designed PV system was 6.48 kWh and monthly energy production was 201 kWh in the month of May. SoSiT results showed that the PV system fulfilled the required crop requirement by only using 28% of the potential water supply, and 72% of the potential water supply from a solar-powered pump was not used. This value is high, and it is recommended to grow more or different crops to utilize the fuel-free electricity from the PV system. The unit cost of PV-powered drip irrigation is USD 0.1013/kWh, which is 4.74% and 66.26% lower than the cost of subsidized electricity and diesel, respectively.

7 September 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
SHSalman Habib
Salman Habib
MTMuhammad Tamoor
Muhammad Tamoor
MZMuhammad Ans Zaka
Muhammad Ans Zaka
YJYouwei Jia
Youwei Jia