Bijan Shirinzadeh

Prof. Bijan Shirinzadeh

Department of Mechanical and Aerospace Engineering, Monash University, Melbourne 3800, Australia

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2013 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
YQYanding Qin
Yanding Qin
Bijan ShirinzadehBijan Shirinzadeh
Bijan Shirinzadeh
DZDawei Zhang
Dawei Zhang
YTYanling Tian
Yanling Tian

3 August 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
HWHuaxian Wei
Huaxian Wei
Bijan ShirinzadehBijan Shirinzadeh
Bijan Shirinzadeh
WLWei Li
Wei Li
LCLeon Clark
Leon Clark
JPJoshua Pinskier
Joshua Pinskier
YWYuqiao Wang
Yuqiao Wang
Compliant bridge mechanisms are frequently utilized to scale micrometer order motions of piezoelectric actuators to levels suitable for desired applications. Analytical equations have previously been specifically developed for two configurations of bridge mechanisms: parallel and rhombic type. Based on elastic beam theory, a kinematic analysis of compliant bridge mechanisms in general configurations is presented. General equations of input displacement, output displacement, displacement amplification, input stiffness, output stiffness and stress are presented. Using the established equations, a piezo-driven compliant bridge mechanism has been optimized to maximize displacement amplification. The presented equations were verified using both computational finite element analysis and through experimentation. Finally, comparison with previous studies further validates the versatility and accuracy of the proposed models. The formulations of the new analytical method are simplified and efficient, which help to achieve sufficient estimation and optimization of compliant bridge mechanisms for nano-positioning systems.

14 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AEArmin Ehrampoosh
Armin Ehrampoosh
Bijan ShirinzadehBijan Shirinzadeh
Bijan Shirinzadeh
JPJoshua Pinskier
Joshua Pinskier
JSJulian Smith
Julian Smith
RMRandall Moshinsky
Randall Moshinsky
Yongmin ZhongYongmin Zhong
Yongmin Zhong
With robotic-assisted minimally invasive surgery (RAMIS), patients and surgeons benefit from a reduced incision size and dexterous instruments. However, current robotic surgery platforms lack haptic feedback, which is an essential element of safe operation. Moreover, teleportation control challenges make complex surgical tasks like suturing more time-consuming than those that use manual tools. This paper presents a new force-sensing instrument that semi-automates the suturing task and facilitates teleoperated robotic manipulation. In order to generate the ideal needle insertion trajectory and pass the needle through its curvature, the end-effector mechanism has a rotating degree of freedom. Impedance control was used to provide sensory information about needle–tissue interaction forces to the operator using an indirect force estimation approach based on data-based models. The operator’s motion commands were then regulated using a hyperplanar virtual fixture (VF) designed to maintain the desired distance between the end-effector and tissue surface while avoiding unwanted contact. To construct the geometry of the VF, an optoelectronic sensor-based approach was developed. Based on the experimental investigation of the hyperplane VF methodology, improved needle–tissue interaction force, manipulation accuracy, and task completion times were demonstrated. Finally, experimental validation of the trained force estimation models and the perceived interaction forces by the user was conducted using online data, demonstrating the potential of the developed approach in improving task performance.

30 November 2022 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
HWHuaxian Wei
Huaxian Wei
YTYanling Tian
Yanling Tian
YZYongjie Zhao
Yongjie Zhao
MLMingxiang Ling
Mingxiang Ling
Bijan ShirinzadehBijan Shirinzadeh
Bijan Shirinzadeh

13 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TBTaran Batty
Taran Batty
AEArmin Ehrampoosh
Armin Ehrampoosh
Bijan ShirinzadehBijan Shirinzadeh
Bijan Shirinzadeh
Yongmin ZhongYongmin Zhong
Yongmin Zhong
JSJulian Smith
Julian Smith
In recent years, robotic minimally invasive surgery has transformed many types of surgical procedures and improved their outcomes. Implementing effective haptic feedback into a teleoperated robotic surgical system presents a significant challenge due to the trade-off between transparency and stability caused by system communication time delays. In this paper, these time delays are mitigated by implementing an environment estimation and force prediction methodology into an experimental robotic minimally invasive surgical system. At the slave, an exponentially weighted recursive least squares (EWRLS) algorithm estimates the respective parameters of the Kelvin–Voigt (KV) and Hunt–Crossley (HC) force models. The master then provides force feedback by interacting with a virtual environment via the estimated parameters. Palpation experiments were conducted with the slave in contact with polyurethane foam during human-in-the-loop teleoperation. The experimental results indicated that the prediction RMSE of error between predicted master force feedback and measured slave force was reduced to 0.076 N for the Hunt–Crossley virtual environment, compared to 0.356 N for the Kelvin–Voigt virtual environment and 0.560 N for the direct force feedback methodology. The results also demonstrated that the HC force model is well suited to provide accurate haptic feedback, particularly when there is a delay between the master and slave kinematics. Furthermore, a haptic feedback approach that incorporates environment estimation and force prediction improve transparency during teleoperation. In conclusion, the proposed bilateral master–slave robotic system has the potential to provide transparent and stable haptic feedback to the surgeon in surgical robotics procedures.

4 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WWWeichen WEI
Weichen WEI
Bijan ShirinzadehBijan Shirinzadeh
Bijan Shirinzadeh
RNRohan Nowell
Rohan Nowell
MGMohammadali Ghafarian
Mohammadali Ghafarian
MAMohamed Ammar
Mohamed Ammar
TSTianyao Shen
Tianyao Shen
Solid-State LiDAR (SSL) takes an increasing share of the LiDAR market. Compared with traditional spinning LiDAR, SSLs are more compact, energy-efficient and cost-effective. Generally, the current study of SSL mapping is limited to adapting existing SLAM algorithms to an SSL sensor. However, compared with spinning LiDARs, SSLs are different in terms of their irregular scan patterns and limited FOV. Directly applying existing SLAM approaches on them often increase the instability of a mapping process. This study proposes a systematic design, which consists of a dual-LiDAR mapping system and a three DOF interpolated six DOF odometry. For dual-LiDAR mapping, this work uses a 2D LiDAR to enhance a 3D SSL performance on a ground vehicle platform. The proposed system takes a 2D LiDAR to preprocess the scanning field into a number of feature sections according to the curvatures on the 2D fraction. Subsequently, this section information is passed to 3D SSL for direction feature selection. Additionally, this work proposes an odometry interpolation method which uses both LiDARs to generate two separated odometries. The proposed odometry interpolation method selectively determines the appropriate odometry information to update the system state under challenging conditions. Experiments are conducted in different scenarios. The results proves that the proposed approach is able to utilise 12 times more corner features from the environment than the comparied method, thus results in a demonstrable improvement in its absolute position error.