Hugo Dinis

Mr. Hugo Dinis

CMEMS-UMinho
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
HDHugo Dinis
Hugo Dinis
PMP.M. Mendes
P.M. Mendes

12 December 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
HDHugo Dinis
Hugo Dinis
ICIvo Colmiais
Ivo Colmiais
PMP. M. Mendes
P. M. Mendes
Implantable electronic devices have been evolving at an astonishing pace, due to the development of fabrication techniques and consequent miniaturization, and a higher efficiency of sensors, actuators, processors and packaging. Implantable devices, with sensing, communication, actuation, and wireless power are of high demand, as they pave the way for new applications and therapies. Long-term and reliable powering of such devices has been a challenge since they were first introduced. This paper presents a review of representative state of the art implantable electronic devices, with wireless power capabilities, ranging from inductive coupling to ultrasounds. The different power transmission mechanisms are compared, to show that, without new methodologies, the power that can be safely transmitted to an implant is reaching its limit. Consequently, a new approach, capable of multiplying the available power inside a brain phantom for the same specific absorption rate (SAR) value, is proposed. In this paper, a setup was implemented to quadruple the power available in the implant, without breaking the SAR limits. A brain phantom was used for concept verification, with both simulation and measurement data.

23 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MSMarwa Slimi
Marwa Slimi
BJbassem jmai
bassem jmai
HDHugo Dinis
Hugo Dinis
AGAli Ghrsallah
Ali Ghrsallah
PMP. M. Mendes
P. M. Mendes
The objective of this work is the design and validation of a directional Vivaldi antenna to detect tumor cells’ electromagnetic waves with a frequency of around 5 GHz. The proposed antenna is 33% smaller than a traditional Vivaldi antenna due to the use of metamaterials in its design. It has an excellent return loss of 25 dB at 5 GHz and adequate radiation characteristics as its gain is 6.2 dB at 5 GHz. The unit cell size of the proposed metamaterial is 0.058λ × 0.054λ at the operation frequency of 5 GHz. The proposed antenna was designed and optimized in CST microwave software, and the measured and simulated results were in good agreement. The experimental study demonstrates that an array composed with the presented antennas can detect the existence of tumors in a liquid breast phantom with positional accuracy through the analysis of the minimum amplitude of Sii.

1 February 2015
Verified
Conference Paper
Closed access
APAdriano Pinto
Adriano Pinto
SPSergio Pereira
Sergio Pereira
HDHugo Dinis
Hugo Dinis
CSCarlos A. Silva
Carlos A. Silva
DRDeolinda M. L. Dias Rasteiro
Deolinda M. L. Dias Rasteiro
Brain tumour segmentation from Magnetic Resonance Imaging (MRI) scans have an important role in the early tumour diagnosis and radiotherapy planning. However, MRI images of the brain contain complex characteristics, such as high diversity in tumour appearance and ambiguous tumour boundaries, even when using multi-sequence MRI images. We propose a fully automatic segmentation algorithm based on a Random Decision Forest, using a k-fold cross-validation approach. The extracted features are the intensity complemented with other appearance and context based features. The post-processing phase has a morphological filter to deal with misclassification errors. Our method is capable of detecting the tumour and segmenting the different tumorous tissues of the glioma achieving competitive results.

21 March 2023 in Electronics
Verified
Journal Article
Open access
PDF file
MBMajdi Bahrouni
Majdi Bahrouni
Gregory HouzetGregory Houzet
Gregory Houzet
TVTan Phu Vuong
Tan Phu Vuong
PMP. M. Mendes
P. M. Mendes
HDHugo Dinis
Hugo Dinis
HTHichem Trabelsi
Hichem Trabelsi
Different implantable antenna designs exist to establish communication with implantable devices depending on the domain of use and the implantation space. Owing to their nature and purposes, these antennas have many imposed criteria on various characteristics, such as bandwidth, multiband behavior, radiation pattern, gain, and specific absorption rate (SAR). This presents a challenge when it comes to achieving satisfying results without a major compromise in any of these crucial parameters. Additionally, many of the existing designs do not follow a specific approach to obtain results. Measuring different parameters of such fabricated structures requires special conditions and special environments mimicking the tissues where they are supposed to be placed. For such issues, the use of biological or synthetic phantoms is widely employed to validate what is obtained in simulation, and a multitude of formulas exist for the creation of such phantoms, each with its advantages and drawbacks. In this paper, a miniature dual-band structure derived from the first iteration of the Koch fractal structure is designed to operate 2 mm below the skin in the arm of the human body, with the MICS (Medical Implant Communication System) and ISM (Industrial, Scientific, Medical) 2.4 GHz bands. The purposes of the design are to derive structures from commonly used shapes with certain behavior while maintaining miniaturization, and to easily design dual-band implantable antennas. More than one band is used to diversify uses, since bands such as the MICS band are mainly dedicated to telemetry. The structure is characterized not only by its low profile compared to various structures found in the literature with dimensions of 17.2 × 14.8 × 0.254 mm3, but also its ease of design, independent shifting of resonant frequencies, and the absence of the need for a matching circuit and a shorting pin (via) for miniaturization. It exhibits satisfying performance: bandwidths of 23 MHz in the MICS band and 190 and 70 MHz in the vicinity of the ISM 2.4 GHz band, and measured gain in the latter band of −18.66 and −17 dBi in the azimuth and elevation radiation patterns, respectively. To validate the antenna’s properties in a skin-mimicking environment, two simple phantom formulas found in the literature were explored and compared in order to identify the best option in terms of accuracy and ease of fabrication.

4 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KMKawther Mekki
Kawther Mekki
Omrane NecibiOmrane Necibi
Omrane Necibi
HDHugo Dinis
Hugo Dinis
PMP. M. Mendes
P. M. Mendes
AGAli Ghrsallah
Ali Ghrsallah
A novel methodology is proposed to reliably predict the resonant characteristics of a multipatch backscatter-based radio frequency identification (RFID) chipless tag. An ultra-wideband impulsion radio (UWB-IR)-based reader interrogates the chipless tag with a UWB pulse, and analyzes the obtained backscatter in the time domain. The RFID system consists of a radar cross-section (RCS)-based chipless tag containing a square microstrip patch antenna array in which the chipless tag is interrogated with a UWB pulse by an UWB-IR-based reader. The main components of the backscattered signal, the structural mode, and the antenna mode were identified and their spectral quality was evaluated. The study revealed that the antenna-mode backscatter includes signal carrying information, while the structural mode backscatter does not include any tag information. The simulation findings were confirmed by experimental measurements obtained in an anechoic chamber environment using a 6-bit multipatch chipless RFID tag. Finally, the novel technique does not use calibration tags and can freely orient tags with respect to the reader.