Michael Schäferling

Dr. Michael Schäferling

Department of Chemical Engineering, FH Münster University of Applied Sciences, Stegerwaldstr. 39, D-48565 Steinfurt, Germany
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2019 in Langmuir
Verified
Journal Article
Closed access
EAElina Andresen
Elina Andresen
URUte Resch-Genger
Ute Resch-Genger
Michael SchäferlingMichael Schäferling
Michael Schäferling

27 January 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
JBJuergen Bartelmess
Juergen Bartelmess
DZDavid Zimmek
David Zimmek
MBMatthias Bartholmai
Matthias Bartholmai
CSChristoph Strangfeld
Christoph Strangfeld
Michael SchäferlingMichael Schäferling
Michael Schäferling
In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures.

16 April 2002 in European Journal of Organic Chemistry
Verified
Journal Article
Closed access
PDF file
SHSiegfried Hünig
Siegfried Hünig
SASven Aldenkortt
Sven Aldenkortt
PBPeter Bäuerle
Peter Bäuerle
CBChristoph A. Briehn
Christoph A. Briehn
Michael SchäferlingMichael Schäferling
Michael Schäferling
BWBernhard Walfort
Bernhard Walfort

23 February 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
Michael SchäferlingMichael Schäferling
Michael Schäferling
VOVladimir Ondrus
Vladimir Ondrus
Imaging methods by the means of optical sensors are applied in diverse scientific areas such as medical research and diagnostics, aerodynamics, environmental analysis, or marine research. After a general introduction to the field, this review is focused on works published between 2012 and 2022. The covered topics include planar sensors (optrodes), nanoprobes, and sensitive coatings. Advanced sensor materials combined with imaging technologies enable the visualization of parameters which exhibit no intrinsic color or fluorescence, such as oxygen, pH, CO2, H2O2, Ca2+, or temperature. The progress on the development of multiple sensors and methods for referenced signal read out is also highlighted, as is the recent progress in device design and application formats using model systems in the lab or methods for measurements’ in the field.

26 April 2013 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
JNJ Napp
J Napp
TBT Behnke
T Behnke
LFL Fischer
L Fischer
CWCh Würth
Ch Würth
MWM Wottawa
M Wottawa
Michael SchäferlingMichael Schäferling
Michael Schäferling
Ziele: Hypoxia is one of the major attributes of solid tumors, caused by a combination of an increased oxygen consumption and usually insufficient oxygen supply. Therefore, there is a high demand for sensitive and cost effective tools for the determination of tumor oxygenation in vivo and in real time. Here, we present the development and the first in vitro and in vivo application of NIR-emissive polystyrene nanobeads with high potential for measurements of the tumor oxygen levels in vivo. Methode: 100 nm polystyrene nanoparticles were dopes with an oxygen-sensitive phosphorescent Pd(II) porphyrin and an innert reference dye, both excitable at 635 nm. With this probe (Ox-NP), the oxygen partial pressure can be obtained by calculating the ratio of oxygen-sensitive (lambdaem = 800 nm) and the reference (lambdaem = 675 nm) dye emission. MH-S macrophages were used for NIRF microscopy. The applicability of the Ox-NPs for in vivo imaging was evaluated in nude mice bearing subcutaneous human tumor xenografts with the Optix MX2. Ergebnis: The phosphorescence of oxygen-sensitive dye is completely quenched in oxygen-saturated solution, while the reference signal is not affected. A linear relation between the oxygen concentration and the ratiometric response of Ox-NP was measured, with a –4-fold increase in signal intensity for oxygen-free conditions. The intensity ratio was strongly increased in macrophages incubated with Ox-NP under hypoxic conditions (1% and 5% O2) in comparison to cells incubated in 20% O2. The accumulation of the hypoxia marker HIF-1a, analyzed by Western blot confirmed the hypoxic status of the cells. First results in tumor-bearing mice showed passive accumulation of the probe in tumor and an increase in the ratiometric response between high and low oxygen conditions in tumor tissue. Schlussfolgerung: We developed a novel NIR fluorescent ratiometric system consisting of dye-loaded polystyrene nanoparticles that can be applied for in vitro and in vivo oxygen sensing. Korrespondierender Autor: Napp J Universitätsmedizin Göttingen, Diagnostische Radiologie, Robert-Koch Str. 40, 37075 Göttingen E-Mail: [email protected]