Christoph Strangfeld

Dr. Christoph Strangfeld

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2016 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
CSChristoph Strangfeld
Christoph Strangfeld
HMH. Müller-Vahl
H. Müller-Vahl
CNChristian Navid Nayeri
Christian Navid Nayeri
CPChristian Oliver Paschereit
Christian Oliver Paschereit
DGDavid Greenblatt
David Greenblatt
A combined theoretical and experimental investigation was carried out with the objective of evaluating theoretical predictions relating to a two-dimensional airfoil subjected to high amplitude harmonic oscillation of the free stream at constant angle of attack. Current theoretical approaches were reviewed and extended for the purposes of quantifying the bound, unsteady vortex sheet strength along the airfoil chord. This resulted in a closed form solution that is valid for arbitrary reduced frequencies and amplitudes. In the experiments, the bound, unsteady vortex strength of a symmetric 18 % thick airfoil at low angles of attack was measured in a dedicated unsteady wind tunnel at maximum reduced frequencies of 0.1 and at velocity oscillations less than or equal to 50 %. With the boundary layer tripped near the leading edge and mid-chord, the phase and amplitude variations of the lift coefficient corresponded reasonably well with the theory. Near the maximum lift coefficient overshoot, the data exhibited an additional high-frequency oscillation. Comparisons of the measured and predicted vortex sheet indicated the existence of a recirculation bubble upstream of the trailing edge which sheds into the wake and modifies the Kutta condition. Without boundary layer tripping, a mid-chord bubble is present that strengthens during flow deceleration and its shedding produces a dramatically different effect. Instead of a lift coefficient overshoot, as per the theory, the data exhibit a significant undershoot. This undershoot is also accompanied by high-frequency oscillations that are characterized by the bubble shedding. In summary, the location of bubble and its subsequent shedding play decisive roles in the resulting temporal aerodynamic loads.

13 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CSChristoph Strangfeld
Christoph Strangfeld
SJSergej Johann
Sergej Johann
MBMatthias Bartholmai
Matthias Bartholmai
In civil engineering, many structures are made of reinforced concrete. Most degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture. Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days. Moreover, long-term moisture monitoring is performed for more than 1000 days. The experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.

1 June 2021 in Journal of Magnetic Resonance Open
Verified
Journal Article
Open access
SNSarah Mandy Nagel
Sarah Mandy Nagel
CSChristoph Strangfeld
Christoph Strangfeld
SKSabine Kruschwitz
Sabine Kruschwitz

31 May 2021 in Advanced Engineering Materials
Verified
Journal Article
Open access
PDF file
CSChristoph Strangfeld
Christoph Strangfeld
The effective gas diffusion coefficient describes the process of gas diffusion in porous materials. Several materials have a significant number of micropores in the lower nanometre range leading to a reduction of gas diffusion (Knudsen effect). In the case of partial pore saturation during adsorption, the available pore space is further reduced, as is the gas diffusion. In this study, the influence of partially saturated pores on the Knudsen effect and on the gas diffusion is quantified. Three different pore geometries are investigated (slit, cylindrical and spherical pores) and three different types of pore size distribution, including a broad equal distribution, three narrow normal distributions and two measured distributions of concrete. Besides the intensive computation of the exact pore saturation, a simplified model with low computational requirements is suggested. This study shows that the influence of the water layer thickness on the effective diffusion becomes significant for pore radii below 50 nm and the assumed pore geometry is important. At the end, the overall effect is quantified for an amorphous material with most pore radii below 30 nm. At a moisture level of 50% relative humidity, the effective diffusion is reduced by 35% due to partial saturation.

27 January 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
JBJuergen Bartelmess
Juergen Bartelmess
DZDavid Zimmek
David Zimmek
MBMatthias Bartholmai
Matthias Bartholmai
CSChristoph Strangfeld
Christoph Strangfeld
Michael SchäferlingMichael Schäferling
Michael Schäferling
In this communication a novel concept for pH sensing is introduced which is specifically adapted to monitor carbonation induced corrosion in concrete structures.

28 January 2024 in Advanced Materials
Verified
Journal Article
Open access
BBBenjamin Bühling
Benjamin Bühling
SMStefan Maack
Stefan Maack
CSChristoph Strangfeld
Christoph Strangfeld
Air‐coupled ultrasonic testing (ACU) is a pioneering technique in non‐destructive testing (NDT). While contact testing and fluid immersion testing are standard methods in many applications, the adoption of ACU is progressing slowly, especially in the low ultrasonic frequency range. A main reason for this development is the difficulty of generating high amplitude ultrasonic bursts with equipment that is robust enough to be applied outside a laboratory environment. This paper presents the fluidic ultrasonic transducer as a solution to this challenge. This novel aeroacoustic source uses the flow instability of a sonic jet in a bistable fluidic switch to generate ultrasonic bursts up to 60 kHz with a mean peak pressure of 320 Pa. The robust design allows operation in adverse environments, independent of the operating fluid. Non‐contact through‐transmission experiments are conducted on four materials and compared with the results of conventional transducers. For the first time, it is shown that the novel fluidic ultrasonic transducer provides a suitable acoustic signal for NDT tasks and has potential of furthering the implementation of ACU in industrial applications.