This paper proposes a solution to the problem of improving the reliability of the operation of progressive cavity pump units in deviated and directional wells. High dogleg severity significantly contributes to rod breakage; rods often break close to the “elbows” with a dogleg severity of 2 deg/10 m or higher. Statistical analyses were used to identify the frequency of failures and their impact on the reliability of a PCP unit. The design layout and mathematical model for pump rods’ torsional vibrations in the curved section of a wellbore were developed. A simulation of the curved section was performed. This article provides the basic formulas needed to design a rotating rod string using two reduced discs. The creation of an additional crooked section resulted in multiple reductions in the “resonant” rotational speed and rigidity in the mathematical model. Determining the moment of inertia of the reduced discs’ mass made it possible to determine the sucker-rod string’s stiffness, the circular rotation frequency, and the number of sucker-rod revolutions under resonance. The number of reduced discs on the sucker-rod string depends on the curvature pattern. In summary, a centralizer for a rotating string was designed to reduce the vibration and shock effects of rods on the tubing.
This paper highlights field studies to determine the nature of variations in the load on the sucker-rod string during short-term gas extraction from the wellbore annulus. The results of step-by-step gas extraction from the annular spaces of the wells of fields developed by PJSC TATNEFT are provided. In the course of investigations, we have obtained both the trends of maximum and minimum loads on the polished rod during annular gas extraction, and the dependence of maximum load increment on the rod string with respect to pump size and pressure variation in the annular space. The analysis of the research data resulted in the elaboration of guidelines for short-term extraction of annular gas from wells operated by the PCP units.
1 February 2021 in IOP Conference Series: Earth and Environmental Science
At present, it is becoming more relevant to use other displacing agents, which are more effective in comparison with waterflooding, for increasing oil and gas condensate deposits component recovery. One of such promising methods is simultaneous water and gas injection. In this article, we present the principal options for using simultaneous water and gas injection in Arctic fields, case study of the Urengoyskoye and Prirazlomnoye fields. Technological schemes for its implementation in the Urengoyskoye field at low reservoir pressures are considered. Filtration studies of oil from reservoir models with water-gas mixtures at various gas contents allow increasing hydrocarbon recovery efficiency by determining the area of rational gas contents. For the conditions of the Prirazlomnoye field, the possibility of using pump-ejector system for the utilization of associated petroleum gas has been established.
15 December 2019 in RUDN Journal of Engineering Researches
The proposed solution relates to fluidics and can be used, for example, in the extraction of oil and gas, the collection and preparation of oil, gas and water, the extraction of methane from methane beds, oil refining. The technical result is to increase the efficiency of a liquid-gas ejector by ensuring its work in the field of rational concentrations and salt composition, in which the intensification of energy exchange between the working fluid and the ejected gas is achieved. The essence of the proposed solution: the method of operation of a liquid-gas ejector involves injecting a working fluid with a power pump into the ejector nozzle, pumping gas with an ejector, creating, dispersing and increasing the pressure of a gas-liquid mixture with an ejector using aqueous solutions of salts as a working fluid. The values of the concentration and composition of salts in the working fluid are maintained within the range of rational concentrations and composition of salts, in which increased values of the efficiency of the ejector are achieved. Salts are added to the weakly mineralized aqueous solutions, and the highly mineralized aqueous solutions are diluted with fresh water. As the working fluid, the formation and/or incidentally produced waters of oil, gas, gas condensate and methane-coal deposits, which are aqueous solutions of salts, are used if the composition and concentration of salts in the produced and/or incidentally produced waters are within the range of rational concentrations and composition of salts in which provides an increase in the efficiency of the ejector. The boundaries of the field of rational concentrations and salt composition are preliminarily determined by laboratory bench studies.
1 March 2021 in IOP Conference Series: Earth and Environmental Science
The article discusses the use of separators of mechanical impurities in linear electric plunger submersible pumps units in oil wells. The advantages of these units and their area of application are highlighted. The diagram and description of the bench for conducting researches on the study of submersible unit assembly of the electric plunger pump together with a separator of gas and mechanical impurities are shown. Formulas and results of calculating the settling rate of particles of different diameters are presented. The main dependences of the change in the settling rate of particles depending on the viscosity of the liquid have been determined.